Scolmore DECO User manual

Type
User manual

Scolmore DECO is a range of electrical accessories, including a fused connection unit that allows for safe and easy installation of electrical circuits. It features a sleek and stylish design, making it a suitable choice for both residential and commercial applications. With a voltage rating of 230V and a current rating of 13A, the DECO range is ideal for various electrical needs. Additionally, it offers a variety of mounting options, including metal or plastic back boxes, providing flexibility in installation.

Scolmore DECO is a range of electrical accessories, including a fused connection unit that allows for safe and easy installation of electrical circuits. It features a sleek and stylish design, making it a suitable choice for both residential and commercial applications. With a voltage rating of 230V and a current rating of 13A, the DECO range is ideal for various electrical needs. Additionally, it offers a variety of mounting options, including metal or plastic back boxes, providing flexibility in installation.

After making the connections, screw the fused connection unit gently to the back box
ensuring no wires become trapped.
Screw the accessory fully home making sure, when done, the plate is not distorted.
Mains Wiring:
‘L’ - Live Coloured Brown or Red
- CPC Coloured Green/Yellow
‘N’ - Neutral Coloured Blue or Black
Conductor lengths may be trimmed in certain applications.
Decorative accessory plates are not suitable to be mounted onto wet / damp plaster or paint,
as this may cause the accessory to tarnish.
This range is not suitable for outdoor installation or in areas of high humidity.
For cleaning / polishing of products, use only a soft, dry, clean cloth.
Technical Information
Voltage 230V~ 50Hz
Current Rating 13A
Terminal Size 5mm ø
Torque Value Terminal Screw: 2.0Nm
Cable Size 3 x 2.5mm2 or 2 x 4.0mm2
Back Box Depth (Min) 25mm (Deco, Deco+, Mode, Polar, Part M, Curva)
35mm (Define, Definity)
Operational Temperature -50 to +450C
Standards The Low Voltage Directive 2014/35/EC
Statutory Instruments 2014/35
BS 1363-4
11mm
PG5 V7.0
Scolmore House | Mariner | Licheld Road Industrial Estate | Tamworth | Staffordshire | B79 7UL | United Kingdom
T: +44 (0)1827 63454 | F: +44 (0)1827 63362 | E: [email protected] | www.scolmore.com
Errors & Omissions excluded. Instructions are subject to change without notice.
Wiring Accessories - Fused Connection Units
Safety, Installation and Technical Information
Safety Information
Please read the following information carefully before commencing installation.
Before commencing any electrical work, to prevent the possibility of receiving
an electric shock, ensure the mains isolator on the consumer unit is in the ‘OFF’
position and safely isolated in accordance with Best Practice Guide 3.
If in doubt consult a qualified electrician. The accessory plate must be installed in
accordance with the latest IET Wiring Regulations, BS7671.
If this product is being fitted as a replacement part to an existing installation account must be
taken to the version of the wiring regulations it was installed to.
Installation Information
If replacing an existing accessory, check the layout of the existing terminals. When removing
the cables from the terminals, note the cable connections in the terminal to ensure correct
wiring of the new accessory.
The mounting box must be of the correct size for the product, metal or plastic. If the back box
has four lugs, then the top and bottom lugs will need to be bent back or removed.
Please see Technical Information overleaf for minimum back box depth, range dependant.
The cable must be routed through the most suitable entry point of the mounting box, taking
note that a suitable protective grommet is recommended should a metal back box be used.
Cables should be prepared to the appropriate lengths (as stated within these instructions)
so that the conductor reaches into the terminal, and the circuit protective conductor is the
longest. The terminals should be tightened to their appropriate torque value (2.0NM). Do not
over tighten.
1 Gang Fused Connection Unit - Unswitched
1 Gang Fused Connection Unit Switched & Flex Outlet
Live Neutral CPC
Lin
Nin
Nout
Lout
Out to load
Supply
In
F
U
S
E
D
Out to load
F
U
S
E
D
E
D
F
U
S
E
D
F
U
S
Replacing the BS 1362 Fuse
Replacing the BS 1362 Fuse
Using a flat bladed screwdrive
r, slot into the groove of the fuse carrier. Fig. 1.
Carefully leaver the screwdriver towards the wall. Fig. 2.
Fig. 1.
Fig. 2.
Fig. 3. Fig. 4.
Pull the fuse drawer towards you Fig. 3., Then push the fuse out, and
replace with new fuse. Fig. 2. Push carrier drawer until flush with the faceplate.
Live NeutralCPC
NOTE: If the carrier has a lockable function, please unlock the drawer first by turning
the screw clockwise 90 degrees.
Locked Unlocked
Out to load
Supply
In
N
OUT
Nin
L
IN
L
OUT
N
OUT
Nin
L
IN
L
OUT
Supply
In
1 Gang Fused Connection Unit - Unswitched
1 Gang Fused Connection Unit Switched & Flex Outlet
Live Neutral CPC
Lin
Nin
Nout
Lout
Out to load
Supply
In
F
U
S
E
D
Out to load
F
U
S
E
D
E
D
F
U
S
E
D
F
U
S
Replacing the BS 1362 Fuse
Replacing the BS 1362 Fuse
Using a flat bladed screwdriver, slot into the groove of the fuse carrier. Fig. 1.
Carefully leaver the screwdriver towards the wall. Fig. 2.
Fig. 1.
Fig. 2.
Fig. 3. Fig. 4.
Pull the fuse drawer towards you Fig. 3., Then push the fuse out, and
replace with new fuse. Fig. 2. Push carrier drawer until flush with the faceplate.
Live NeutralCPC
NOTE: If the carrier has a lockable function, please unlock the drawer first by turning
the screw clockwise 90 degrees.
Locked Unlocked
Out to load
Supply
In
N
OUT
Nin
L
IN
L
OUT
N
OUT
Nin
L
IN
L
OUT
Supply
In
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Scolmore DECO User manual

Type
User manual

Scolmore DECO is a range of electrical accessories, including a fused connection unit that allows for safe and easy installation of electrical circuits. It features a sleek and stylish design, making it a suitable choice for both residential and commercial applications. With a voltage rating of 230V and a current rating of 13A, the DECO range is ideal for various electrical needs. Additionally, it offers a variety of mounting options, including metal or plastic back boxes, providing flexibility in installation.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI