Knightsbridge HBN150 User manual

Type
User manual

Knightsbridge HBN150 is a versatile and durable lighting solution suitable for indoor industrial and commercial applications. With its IP65 rating, it can withstand dust and water, making it ideal for harsh environments. Installation is straightforward, with suspension or bracket mounting options available. The luminaire can be used with or without a dimmer, and it is compatible with 1-10V dimmers for precise light control. Additionally, a microwave sensor can be integrated for motion-activated lighting, enhancing energy efficiency and security.

Knightsbridge HBN150 is a versatile and durable lighting solution suitable for indoor industrial and commercial applications. With its IP65 rating, it can withstand dust and water, making it ideal for harsh environments. Installation is straightforward, with suspension or bracket mounting options available. The luminaire can be used with or without a dimmer, and it is compatible with 1-10V dimmers for precise light control. Additionally, a microwave sensor can be integrated for motion-activated lighting, enhancing energy efficiency and security.

INSTALLATION & MAINTENANCE MANUAL
HBN SERIES
GENERAL INSTRUCTIONS
These instructions should be read carefully and retained after installation by the end
user for future reference and maintenance.
These instructions should be used to aid installation of the following products:
HBN150 / HBN200
SAFETY
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
• Please isolate mains prior to installation or maintenance
Check the total load on the circuit (including when this luminaire is fitted) does not exceed the
rating of the circuit cable, fuse or circuit breaker
Please note the IP (Ingress Protection) rating of this luminaire when deciding the
location for installation
This product is for indoor use only
This product is Class I and must be earthed
This product is IP65 rated
INSTALLATION
Provide power to the required point of installation. Suitable IP rated junction boxes should be
used where required
Suspension mounting
To suspend the fitting, screw the mounting hoop into the top of the luminaire and secure with the
screw provided (see Fig. 1)
HBLseries
Theseinstructionsshouldbereadcarefullyandretainedafterinstallationbytheenduserforfuturereferenceand
maintenance.
Theseinstructionsshouldbeusedtoaidinstallationofthefollowingproducts:
HBL100/HBL150/HBL200/HBL240
SAFETY
Installationofthisluminaireshouldonlybecarriedoutbyaqualifiedelectricianorcompetentpersontothe
latestBuildingandcurrentIEEWiringRegulations(BS7671)
Pleaseisolatemainspriortoinstallation/maintenance
Checkthetotalloadonthecircuit(includingwhenthisluminaireisfitted)doesnotexceedtheratingofthe
circuitcable,fuseorcircuitbreaker
PleasenotetheIP(IngressofProtection)ratingofthisluminairewhendecidingthelocationforinstallation
ThisproductseriesisClassIandrequiresanearth
ThisproductseriesisIP65rated(recommendedindooruseonly)
Thisproductisdimmableviaa1-10Vdimmer
INSTALLATION
Providepowertotherequiredpointofinstallation.SuitableIPratedjunctionsboxesshouldbeusedwhere
required
Suspensionmounting
Tosuspendthefitting,screwthemountinghoopintothetopoftheluminaire(seeFig1)
Fig1
Bracketmounting
Usingthebracketasatemplate,markthelocationofthefixingholes,drill2x10mmholesensuringnotto
infringewithanyjoists,gasorwaterpipesorelectricalcables
Usingahammer,taptheexpansionboltsintothe10mmfixingholes(seeFig2)
Fig2
Screwdown
mountinghoop
Fig. 1
Secure with screw
Bracket mounting
Using the bracket as a template, mark the location of the fixing holes, drill 2 x 10mm holes
ensuring not to infringe with any joists, gas/water pipes or electrical cables
• Using a hammer, tap the expansion bolts into the 10mm fixing holes (see Fig. 2)
HBLseries
Theseinstructionsshouldbereadcarefullyandretainedafterinstallationbytheenduserforfuturereferenceand
maintenance.
Theseinstructionsshouldbeusedtoaidinstallationofthefollowingproducts:
HBL100/HBL150/HBL200/HBL240
SAFETY
Installationofthisluminaireshouldonlybecarriedoutbyaqualifiedelectricianorcompetentpersontothe
latestBuildingandcurrentIEEWiringRegulations(BS7671)
Pleaseisolatemainspriortoinstallation/maintenance
Checkthetotalloadonthecircuit(includingwhenthisluminaireisfitted)doesnotexceedtheratingofthe
circuitcable,fuseorcircuitbreaker
PleasenotetheIP(IngressofProtection)ratingofthisluminairewhendecidingthelocationforinstallation
ThisproductseriesisClassIandrequiresanearth
ThisproductseriesisIP65rated(recommendedindooruseonly)
Thisproductisdimmableviaa1-10Vdimmer
INSTALLATION
Providepowertotherequiredpointofinstallation.SuitableIPratedjunctionsboxesshouldbeusedwhere
required
Suspensionmounting
Tosuspendthefitting,screwthemountinghoopintothetopoftheluminaire(seeFig1)
Fig1
Bracketmounting
Usingthebracketasatemplate,markthelocationofthefixingholes,drill2x10mmholesensuringnotto
infringewithanyjoists,gasorwaterpipesorelectricalcables
Usingahammer,taptheexpansionboltsintothe10mmfixingholes(seeFig2)
Fig2
Screwdown
mountinghoop
Fig. 2
Tighten expansion bolt nuts but allow enough space for the bracket to mount
• Remove the driver housing via the 4 Allen screws (see Fig. 3)
Align the mounting bracket with 2 of the driver housing screw pillars (see Fig. 4)
Tightenexpansionboltnutsbutallowenoughspaceforthebrackettomount
Removethedriverhousingviathe4Allenscrews(seeFig3)
Fig3
Alignthemountingbracketwith2ofthedriverhousingscrewpillars(seeFig4)
Fig4
PositionthedriverhousingintothebracketensuringallAllenscrewholesarecorrectlyalignedandfastendown
the4Allenscrews(seeFig5)
Fig5
Removethe4Allenscrews
FastendownAllenscrews
Tightenexpansionboltnutsbutallowenoughspaceforthebrackettomount
Removethedriverhousingviathe4Allenscrews(seeFig3)
Fig3
Alignthemountingbracketwith2ofthedriverhousingscrewpillars(seeFig4)
Fig4
PositionthedriverhousingintothebracketensuringallAllenscrewholesarecorrectlyalignedandfastendown
the4Allenscrews(seeFig5)
Fig5
FastendownAllenscrews
Fig. 3
Fig. 4
Tightenexpansionboltnutsbutallowenoughspaceforthebrackettomount
Removethedriverhousingviathe4Allenscrews(seeFig3)
Fig3
Alignthemountingbracketwith2ofthedriverhousingscrewpillars(seeFig4)
Fig4
PositionthedriverhousingintothebracketensuringallAllenscrewholesarecorrectlyalignedandfastendown
the4Allenscrews(seeFig5)
Fig5
Removethe4Allenscrews
FastendownAllenscrews
Liftthefittinguptotheexpansionboltsandslideintothebracket(seeFig6)
Fig6
Tightenthe2expansionboltstosecuretheluminairetothesurface
Towiretheluminairewithoutadimmer(seefig7)
Fig7
Towiretheluminairewitha1-10Vdimmer(seeFig8)
Live-brown
Earth–green/yellow
Neutral-blue
Blue:Dim+
White:Dim-
Neutral-blue
Earth–green/yellow
Live-brown
Position the driver housing over the bracket ensuring all Allen screw holes are correctly aligned
and fasten down the 4 Allen screws (see Fig. 5)
• Lift the fitting up to the expansion bolts and slide into the bracket (see Fig. 6)
Fig. 5
Fig. 6
Liftthefittinguptotheexpansionboltsandslideintothebracket(seeFig6)
Fig6
Tightenthe2expansionboltstosecuretheluminairetothesurface
Towiretheluminairewithoutadimmer(seefig7)
Fig7
Towiretheluminairewitha1-10Vdimmer(seeFig8)
Live-brown
Earth–green/yellow
Neutral-blue
Blue:Dim+
White:Dim-
Neutral-blue
Earth–green/yellow
Live-brown
Tighten the two expansion bolts to secure the luminaire to the surface
Ensuring correct polarity is observed, carefully wire as shown in Figs. 7-9. Suitable IP rated
junction boxes should be used where required
Fig. 7
Wiring Schemes
Liftthefittinguptotheexpansionboltsandslideintothebracket(seeFig6)
Fig6
Tightenthe2expansionboltstosecuretheluminairetothesurface
Towiretheluminairewithoutadimmer(seefig7)
Fig7
Towiretheluminairewitha1-10Vdimmer(seeFig8)
Live-brown
Earth–green/yellow
Neutral-blue
Blue:Dim+
White:Dim-
Neutral-blue
Earth–green/yellow
Live-brown
To wire the luminaire with a 1-10V dimmer (not supplied) see Fig. 8
Fig. 8
Purple: dim+
Grey: dim-
To wire the luminaire with microwave sensor HBNS see Fig. 9
• Switch on and check for correct operation
Fig. 9
INSTRUCTIONS
These instructions should be read carefully and retained after installation by the end-user for future reference and
maintenance.
These instructions should be used to aid the installation of the following products:
HBNS1 / HBLS1
SAFETY
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
Please isolate mains prior to installation or maintenance
Check the total load on the circuit (including when this sensor is fitted) does not exceed the rating of
the circuit cable, fuse or circuit breaker
Please note the IP (Ingress Protection) rating of this product when deciding the location for
installation
This product is Class II double insulated
This product is IP65 rated (indoor use only)
INSTALLATION
This product is designed for use with the HBN / HBL range of luminaires
Line up the sensor bracket with the holes on the luminaire and secure using the 2 screws provided
Attach the sensor to the bracket using the 3 screws provided
Ensuring correct polarity is observed, carefully wire as shown in Fig. 1. Suitable IP rated junction
boxes should be used where required
Fig. 1
*HBN High Bay pictured
WARNING
This luminaire must be disconnected from the circuit if subjected to any high voltage
or insulation resistance testing. Irreparable damage will occur if this instruction is not followed.
Ensure correct fixtures are used for the surface to which the luminaire is fixed
DCAUG21_V3
GENERAL
The light source of this luminaire is not replaceable; when the light source reaches its end of life the
whole luminaire should be replaced.
Be aware that these products may require an MCB upgrade to a type C due to high inrush currents
Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which may
damage the product
Do not use any source of high pressure washers to maintain or clean this luminaire
This product is dimmable via a 1-10V dimmer
This product should be recycled in the correct manner when it reaches the end of its life. Check
local authorities for where facilities exist
WARRANTY
This product has a warranty of 5 years from date of purchase. Failure to install this product in
accordance with the current edition of the IEE Wiring Regulations (BS7671), improper use, or
removal of the batch codes will invalidate the warranty. If this product should fail within its warranty
period, it should be returned to the place of purchase for a free of charge replacement. ML
Accessories does not accept responsibility for any installation costs associated with the replacement
product. Your statutory rights are not affected. ML Accessories reserve the right to alter product
specification without prior notice.
ML Accessories Limited LU5 4LT
www.mlaccessories.co.uk
122
INTERNATIONAL
CONTACT DETAILS
INTERNATIONAL
CONTACT DETAILS
INTERNATIONAL
CONTACT DETAILS
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Knightsbridge HBN150 User manual

Type
User manual

Knightsbridge HBN150 is a versatile and durable lighting solution suitable for indoor industrial and commercial applications. With its IP65 rating, it can withstand dust and water, making it ideal for harsh environments. Installation is straightforward, with suspension or bracket mounting options available. The luminaire can be used with or without a dimmer, and it is compatible with 1-10V dimmers for precise light control. Additionally, a microwave sensor can be integrated for motion-activated lighting, enhancing energy efficiency and security.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI