SK-FML/SK-FSL Fiber Option Modules Installation Instructions
2 P/N LS10178-001SK-E Rev A
ECN: 17-0196
Section 3 Installation
Section 3.2 SK-FML/SK-FSL Installation
Section 3.1 Installation Requirements
CAUTION: STATIC SENSITIVE EQUIPMENT:
THIS EQUIPMENT IS SENSITIVE TO STATIC
ELECTRICITY. IT MAY BE DAMAGED IF NOT
PROPERLY HANDLED. TRANSPORT AND STORE
THIS UNIT IN A STATIC-SHIELDING BAG.
FAILURE TO OBSERVE THIS REQUIREMENT
COULD CAUSE LATENT DAMAGE TO THE
EQUIPMENT WHICH MIGHT NOT MANIFEST ITSELF
UNTIL AFTER THE EQUIPMENT IS PLACED IN
SERVICE.
DISCONNECT ALL POWER:
REMOVE ALL SOURCES OF POWER BEFORE YOU
SERVICE, REMOVE OR INSTALL ANY UNITS.
All components should be located per the following
requirements:
• Installations are to be indoors only, in dry loca-
tions, protected from rain, water, and rapid
changes in temperature that could cause con-
densation. Equipment must be securely
mounted on rigid, permanent walls.
• Operating temperature shall not exceed the
range of 32° to 120° F (0 to 49° C).
• Operating humidity not to exceed 93% non-con-
densing at 90° F (32° C).
• All sub-assemblies and components are to be
located in compliance with the local, the national
codes and the manufacturer’s recommenda-
tions.
• All installation field wiring shall be in compliance
with the local code, the national code and the
manufacturer’s recommendations.
• Use the Architects and Engineering Specifica-
tions for detailed information on your Facility’s
Configuration.
1. Remove the unit from its static-shield bag,
observing proper static protection measures.
2. Visually inspect the unit for damage.
If any components are damaged, notify the
shipping carrier immediately. Report missing
components to the Silent Knight Customer
Service.
3. Use the Hardware Kit provided with the unit.
4. Plug the Fiber Module #1 into P6 of the ECS-
NVCM or SK-NIC circuit as shown in Location 1
in Figure 3.2.1 and Figure 3.2.2.
5. To connect the Fiber Module # 1 to the ECS-
NVCM or SK-NIC, insert and secure three
screws (#4-40 x 1/4”) as shown in Location 2 in
Figure 3.2.1 and Figure 3.2.2.
Section 3.2 SK-FML/SK-FSL Installation
(continued)
6. Plug the Fiber Module #1 into P5 of the
ECS-NVCM or SK-NIC circuit as shown in
Location 3 in Figure 3.2.1 and Figure 3.2.2.
7. To connect the Fiber Module #1 to the ECS-
NVCM or SK-NIC, insert and secure three
screws (#4-40 x 1/4”) as shown in Location 4 in
Figure 3.2.1 and Figure 3.2.2.
Figure 3.2.1 illustrates the SK-FML/SK-FSL installed
to the SK-NIC.
Note: FIBER MODULES:SK-FSL AND SK-FML. INSTALL
A MAXIMUM OF TWO BOARDS PER
INSTALLATION.THE FIBER MODULES CAN BE
COMBINED.
Figure 3.2.1 SK-FML Installation
Figure 3.2.2 illustrates the SK-FML/SK-FSL installed
to the ECS-NVCM.
Figure 3.2.2 SK-FSL Installation
2
4
2
2
4
4
4
2
1
1
3
3
4
4
2
2
S
K
-
N
I
C
J6
J5
S
K
-
F
M
L
S
K
-
F
S
L
ABAB
S
K
-
F
M
L
S
K
-
F
S
L
1
FIBER MODULE #2
FIBER MODULE #1
SCREW
(#4-40 X ¼”)
(6.35 mm)
(3 PLACES)
SCREW
(#4-40 X ¼”)
(6.35 mm)
(3 PLACES)
1
2
2
2
4
1
4
3
4
4
4
4
2
1
J5
3
J6
2
2
—
O
U
T
+
V
B
U
S
2
—
I
N
+
—
O
U
T
+
V
B
U
S
1
—
I
N
+
P
O
R
T
1
A
B
P
O
R
T
2
A
B
C
M
D
2
C
O
M
M
O
N
C
M
D
1
A
U
X
A
U
D
I
O
G
N
D
I
N
S
K
-
F
M
L
S
K
-
F
S
L
E
C
S
-
N
V
C
M
FIBER MODULE #2
FIBER MODULE #1
SCREW
(#4-40 X ¼”) (6.35 mm)
(3 PLACES)
SCREW
(#4-40 X ¼”) (6.35 mm)
(3 PLACES)