Kichler Lighting 52282NI is a versatile lighting fixture that offers multiple mounting options for customized illumination in various spaces. Its rigid stem mount allows for adjustable height, while the loop/chain link mount provides a unique and decorative touch. The semi-flush mount option creates a sleek and modern look, making it suitable for both residential and commercial applications. With its durable construction and easy installation process, the Kichler Lighting 52282NI is an ideal choice for enhancing the ambiance of any room.

Kichler Lighting 52282NI is a versatile lighting fixture that offers multiple mounting options for customized illumination in various spaces. Its rigid stem mount allows for adjustable height, while the loop/chain link mount provides a unique and decorative touch. The semi-flush mount option creates a sleek and modern look, making it suitable for both residential and commercial applications. With its durable construction and easy installation process, the Kichler Lighting 52282NI is an ideal choice for enhancing the ambiance of any room.

IS-52282-US
Were here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
11) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth
(see illus.)
Neutral Wire
12) Raise xture to ceiling, carefully passing mounng screws
through holes in canopy[G]. NOTE: Be certain wires do
not get pinched between canopy and ceiling.
13) Use knobs[J] and lockwashers[I] to secure canopy.
Tighten to secure.
14) Raise the glass[S] up over the socket[P] unl seated.
15) Thread the socket ring[R] onto the socket up to the glass
to secure the glass in place.
16) Insert recommended bulbs. (Not supplied).
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fusebox before starng and during
the installaon.
WARNING:
This xture is intended for installaon in accordance with the Naonal Electrical Code (NEC) and all
local code specicaons. If you are not familiar with code requirements, installaon by a cered
electrician is recommended.
CLEANING:
• Always be certain that electric current is turned o before cleaning.
• Only a so damp cloth should be used. Harsh cleaning products may damage the nish.
Installaon Instrucons
[A] Stems
[B] Short Threaded Tubes
[C] Outlet Box
[D] Lockwasher
[E] Hexnut
[F] Mounting Strap
[G] Canopy
[H] Strap Mounting Screws
[I] Lockwashers
[J] Knobs
[K] Second Loop
[L] Chain Link
[M] Mounting Screws
[N] Main Body
[O] First Loop
[P] Socket
[Q] 3-inch Tube
[R] Socket Ring
[S] Glass
RIGID STEM MOUNT
1) Pass xture wires from main body[N] through 3-inch tube[Q] and screw tube onto threads
protruding at top of main body.
2) Pass xture wires through desired number of stems[A] and screw stems together using supplied
short threaded tubes[B].
NOTE: A minimum of one (1) 12-inch stem must be used when mounng xture. Pass xture
wire through remaining stems and screw stems together.
NOTE: Thread locking compound must be applied to all stem threads as noted with symbol (4)
to prevent accidental rotaon of xture during cleaning, relamping, etc.
3) Screw rst stem into top of the 3-inch tube[Q].
4) Pass xture wires from last stem through one short threaded tube[B].
5) Screw short threaded tube into top of last stem.
6) Pass xture wires through hole in canopy[G]. Lower canopy down towards stem. Pass hole in
canopy over end of short threaded tube on top of stem.
7) Pass xture wires through lockwasher[D] and then through hexnut[E]. Place lockwasher onto
end of short threaded tube protruding from inside canopy and thread hexnut onto tube.
NOTE: Fixture wires should not be cut shorter than 20 inches from above the canopy.
8) Find the appropriate threaded holes on mounng strap[F]. Assemble mounng screws[M] into
threaded holes.
9) Aach mounng strap to outlet box[C] using the strap mounng screws[H]. Mounng strap
can be adjusted to suit posion of xture.
10) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a hole and two raised dimples, wrap
ground wire from outlet box around green ground screw, and thread into hole.
b) On xtures where a cupped washer is provided,aach ground wire from outlet box under
cupped washer and green ground screw, then thread into mounng strap.
If xture is provided with ground wire, connect xture ground wire to outlet box ground wire
with wire connector aer following the above steps. Never connect ground wire to black or
white power supply wires.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Installaon Instrucons (connued)
LOOP / CHAIN LINK MOUNT
1) Follow steps 1 - 3 from “Rigid Stem Mount Instrucons.
2) Pass xture wires from last stem through short threaded
tube[B] and through rst loop[O]. Screw short threaded
tube into top of last stem and into rst loop.
3) Pass xture wires through second loop[K], short threaded
tube, and hole in canopy[G]. Screw short threaded tube into
end of second loop.
4) (If second loop is already aached to canopy, proceed to
next step). Insert short threaded tube at end of second loop
through hole in canopy. Thread lock washer[D] onto short
threaded tube protruding from inside canopy. Pass xture
wires through hexnut[E] and thread hexnut onto end of
short threaded tube.
NOTE: Fixture wires should not be cut shorter than 20
inches from above the canopy.
5) Aach open chain link[L] to loop at end of stem(s) and to
loop on canopy. Once aached, close the open chain link by
placing a piece of cloth over the open link and using a pair of
pliers to gently squeeze the link closed.
6) Follow steps 8 - 16 from “Rigid Stem Mount Instrucons.
SEMI-FLUSH MOUNT
1) Pass xture wires from main body[N] through 3-inch
tube[Q] and screw tube onto threads protruding at top of
main body.
2) Pass xture wires through one short threaded tube[B] and
through hole in center of canopy[G].
3) Screw short threaded tube into top of the 3-inch tube.
4) Slip canopy over exposed threads of short threaded tube
connected to 3-inch tube, making sure the tube passes
through hole in center of canopy.
5) Follow steps 7 - 16 from “Rigid Stem Mount Instrucons.
SEMI-FLUSH MOUNTRIGID STEM MOUNT LOOP / CHAIN LINK
MOUNT
K
L
B
A
B
A
J
I
Q
N
J
I
Q
N
S
R
S
R
B
B
A
A
G
J
I
C
F
M
H
D
E
Q
N
S
R
B
B
G
C
F
M
H
D
E
G
C
F
M
H
D
E
O
P
P P
  • Page 1 1
  • Page 2 2
  • Page 3 3

Kichler Lighting 52282NI User manual

Type
User manual

Kichler Lighting 52282NI is a versatile lighting fixture that offers multiple mounting options for customized illumination in various spaces. Its rigid stem mount allows for adjustable height, while the loop/chain link mount provides a unique and decorative touch. The semi-flush mount option creates a sleek and modern look, making it suitable for both residential and commercial applications. With its durable construction and easy installation process, the Kichler Lighting 52282NI is an ideal choice for enhancing the ambiance of any room.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI