Barco Presentation and Simulation
SERVICE INFORMATION BULLETIN INFOT
Serial number:552
Date: 12122003
Product: Galaxy Warp
TM
InfoT Priority Code
A
”Must” modification, Barco will provide the necessary components to perform this modification
at no charge.
B
Improves the reliability of the product.
C Improves the general working conditions of the product.
D
For information only.
SMPS ADAPTATION FOR STARTUP ERRORS + ER-
ROR 3003
Introduction
Due to the relative high consumption of the Warp
TM
board, the 3V3 supply stabilization is sometimes
subject to tr
ansients influencing the Power Good line.
Priority as
sessment
Priority
A B
C
D
Symptoms
Power Good failure
The Power Good lineisused to monitorseveralvoltagestoinsure properfunctioningofthe variousboards
(formatter,...). However, some spurious events may trigger a Power Good failure.
What can trigger the Power Good failure ?
1. Spikes on the 3V3 overvoltage circuit may lead to a spurious “overvoltage” status.
Errors during Startup
In some cases I9 can go in latch-up causing the projector to switch off again. this can be solved by con-
necting pin 18 to another ground.