ADTRAN 1000 Installation and Maintenance

Type
Installation and Maintenance

ADTRAN 1000 is a versatile device designed to deliver reliable and efficient power solutions for various applications. Its key capabilities include:

  • Power Conversion: ADTRAN 1000 seamlessly converts incoming span power (-95V to -190V) into tightly regulated bus voltages (+5V, +3.3V, +2.5V, and +22V), ensuring stable operation of connected equipment.

  • Plug-and-Play Installation: The device features a simple and convenient plug-and-play installation process, allowing for quick and easy integration into compatible systems.

  • Front Panel LED Indicator: ADTRAN 1000 is equipped with a front panel LED indicator that provides real-time status information. A green LED indicates proper span power and system voltage presence, a blinking LED signifies low input voltage, and an OFF LED indicates the loss of system voltage.

ADTRAN 1000 is a versatile device designed to deliver reliable and efficient power solutions for various applications. Its key capabilities include:

  • Power Conversion: ADTRAN 1000 seamlessly converts incoming span power (-95V to -190V) into tightly regulated bus voltages (+5V, +3.3V, +2.5V, and +22V), ensuring stable operation of connected equipment.

  • Plug-and-Play Installation: The device features a simple and convenient plug-and-play installation process, allowing for quick and easy integration into compatible systems.

  • Front Panel LED Indicator: ADTRAN 1000 is equipped with a front panel LED indicator that provides real-time status information. A green LED indicates proper span power and system voltage presence, a blinking LED signifies low input voltage, and an OFF LED indicates the loss of system voltage.

Section 61179008L1-5, Issue 1
1
61179008L1-5A
1. GENERAL
This practice provides installation and maintenance
procedures for the ADTRAN Total Access 1000
DSLAM ATM Power Supply Unit. Figure 1 is an
illustration of the Total Access 1000 ATM PSU.
Revision History
This is the initial release of this document. Future
revisions to this document will be explained in this
subsection.
Features
The Total Access 1000 DSLAM ATM PSU, P/N
1179008L1, includes the following features:
Converts incoming -190 V span power to
regulated buss voltages.
Provision free plug and play
Front Panel status LED.
Meets FCC, NEBS Level 3, and UL 60950
requirements.
General Description
The Total Access 1000 DSLAM ATM PSU is a
common module plug-in unit designed for use in the
ADTRAN Total Access 1000 DSLAM channel bank.
The PSU accepts span power (-95 V minimun/ -190 V
maximum) from loops terminated on the Line
Interface Unit (P/N 1179109L1). Through
Section 61179008L1-5A
Issue 1, September 2002
CLEI Code: VAPUCJOC_ _
Total Access
®
1000 DSLAM ATM PSU
Installation and Maintenance
Figure 1. Total Access 1000 ATM PSU
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
switchmode operation, the PSU converts the span
voltage to four buss voltages: +5 V, +3.3 V, +2.5 V,
and +22 V. These voltages are distributed on the
Total Access 1000 backplane for use by other cards in
the system.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by
ADTRAN could void the users authority to operate
this equipment.
CONTENTS
1. GENERAL..........................................................1
2. INSTALLATION ...............................................2
3. MAINTENANCE...............................................2
4. SPECIFICATIONS ............................................3
5. WARRANTY AND CUSTOMER SERVICE...3
FIGURE
Figure 1. Total Access 1000 ATM PSU ...................1
TABLES
Table 1. Compliance Codes ...................................... 2
Table 2. Specifications ..............................................3
ATM PSU
1179008L1
POWER
2
61179008L1-5A
Section 61179008L1-5, Issue 1
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
2. INSTALLATION
After unpacking the unit, inspect it for damage. If
damage is noted, file a claim with the carrier, then
contact ADTRAN. Refer to Warranty and Customer
Service.
The Total Access 1000 DSLAM ATM PSU inserts
directly into the common card area in the position
labeled PSU.
To install the PSU, grasp the unit by the front panel
while supporting the bottom side. Align the card
edges to the guide grooves and insert the unit until the
edge connector seats firmly into the backplane. Lock
the card in place by pushing in on the lock levers.
Provisioning Options
The Total Access 1000 DSLAM ATM PSU has no
options or adjustments. It does not require
provisioning prior to insertion into the channel bank.
Front Panel LED
The front panel LED will indicate GREEN when
proper span power voltage is present and system
voltages are present. Low input voltage results in a
blinking LED; an OFF LED indicates the loss of a
system voltage.
Compliance Codes
Table 1 shows the Compliance Codes for the Total
Access 1000 DSLAM ATM PSU. This product is
intended to be installed in products providing a Type
B or E enclosure, and in Restricted Access
Locations.
3. MAINTENANCE
The Total Access 1000 DSLAM ATM PSU does not
require routine maintenance for normal operation.
Field Repairs
ADTRAN does not recommend that repairs be
attempted in the field. Repair services are obtained by
returning the defective unit to ADTRAN Customer
Service Department.
4. SPECIFICATIONS
Refer to Table 2 for a Total Access 1000 DSLAM
ATM PSU Specifications.
5. WARRANTY AND CUSTOMER SERVICE
ADTRAN will replace or repair this product within
ten (10) years from the date of shipment if it does not
meet its published specifications or fails while in
service. Refer to ADTRAN U.S. and Canada Carrier
Networks Equipment Warranty, Document
60000087-10.
Contact Customer And Product Service (CAPS) prior
to returning equipment to ADTRAN.
For service, CAPS requests, or further information,
contact one of the following numbers:
ADTRAN Sales
Pricing and availability
(800) 827-0807
ADTRAN Technical Support
Presales Applications / Post-sale Technical Assistance
(800) 726-8663
Standard support hours:
Monday-Friday, 7 a.m. - 7 p.m. CST
Emergency support:
7 days/week, 24 hours/day
ADTRAN Repair/CAPS
Return for repair / upgrade
(256) 963-8722
Repair and Return Address:
ADTRAN, Inc.
CAPS
901 Explorer Boulevard
Huntsville, Alabama 35806-2807
Code Input Output
Power Code (PC) C C
Telecommunication Code (TC) X
Installation Code (IC) A
Table 1. Compliance Codes
Section 61179008L1-5, Issue 1
3
61179008L1-5A
Table 2. Specifications
rewoP
:tupnI
:stuptuO
CDV091-otCDV59-
A02.0,%01±V22+
A57.1,%5±V0.5+
A00.1,%5±V3.3+
A57.2,%5±V5.2+
latnemnorivnE
:erutarepmeTgnitarepO
:erutarepmeTegarotS
:ytidimuHevitaleR
Cº07otCº04-
Cº58otCº04-
gnisnednocnon,Cº05@mumixam%59
lacisyhP
:snoisnemiDW.ni480.1xH.ni218.2xL.ni528.9
4
61179008L1-5A
Section 61179008L1-5, Issue 1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

ADTRAN 1000 Installation and Maintenance

Type
Installation and Maintenance

ADTRAN 1000 is a versatile device designed to deliver reliable and efficient power solutions for various applications. Its key capabilities include:

  • Power Conversion: ADTRAN 1000 seamlessly converts incoming span power (-95V to -190V) into tightly regulated bus voltages (+5V, +3.3V, +2.5V, and +22V), ensuring stable operation of connected equipment.

  • Plug-and-Play Installation: The device features a simple and convenient plug-and-play installation process, allowing for quick and easy integration into compatible systems.

  • Front Panel LED Indicator: ADTRAN 1000 is equipped with a front panel LED indicator that provides real-time status information. A green LED indicates proper span power and system voltage presence, a blinking LED signifies low input voltage, and an OFF LED indicates the loss of system voltage.

Ask a question and I''ll find the answer in the document