Altronix MAXIMAL33R Datasheet

Category
Power distribution units (PDUs)
Type
Datasheet
Altronix new Maximal33R rack mount access power controller distributes
and switches power to access control systems and accessories. It converts a 115VAC 50/60Hz input into sixteen
(16) independently controlled 12VDC and/or 24VDC fuse protected outputs. Outputs are activated by an normally
open (NO) or normally closed (NC) dry trigger input from an Access Control System,
Card Reader, Keypad, Push Button, PIR, etc. This unit will route
power to a variety of access control hardware devices including:
Mag Locks, Electric Strikes, Magnetic Door Holders, etc.
Outputs will operate in both Fail-Safe and/or Fail-Secure
modes. The FACP Interface enables Emergency Egress, Alarm
Monitoring, or may be used to trigger other auxiliary devices.
The fire alarm disconnect feature is individually selectable
for any or all of the outputs.
Input:
• 115VAC60Hz.,3.8amp.
• Normallyclosed[NC]ornormallyopen[NO]
dry contact inputs (switch selectable).
Outputs:
• 12VDCor24VDC@12amptotaloutputcurrent.
Powersupply1/(8)outputs:
12VDC@6ampor24VDC@6amp
Powersupply2/(8)outputs:
12VDC@6ampor24VDC@6amp
• Sixteen(16)fuseprotectedoutputs.
• MaximumcurrentperACM8R-Moutputis2.5amp.
• IndividuallyselectableMagLock/Strike(Fail-Safe,
Fail-Secure) solid state fuse protected outputs.
• Thermalandshortcircuitprotectionwithautoreset.
Fire Alarm Interface:
• LatchingorNon-Latchingfirealarmresetswitch
individually selectable for each output.
• RemoteresetcapabilityforlatchingFireAlarm
Interface mode.
• FireAlarmdisconnectinputoptions:
a) Normallyopen[NO]ornormallyclosed[NC]
dry contact input.
b) Polarity reversal input from FACP signaling
circuit.
Visual Indicators:
• IndividualOutputStatusLEDslocatedonthe
front panel.
Battery Backup:
• Built-inchargerforsealedleadacidorgeltype
batteries (if batteries are required install
separate enclosure).
• Maximumchargecurrent0.7amp.
• Automaticswitchovertostand-bybattery
when AC fails.
• Zerovoltagedropwhenunitswitchesovertobattery
backup (AC failure condition).
Supervision:
• ACfailsupervision(form“C”contact).
• Lowbatteryandbatterypresencesupervision
(form“C”contact).
Additional Features:
• Removableterminalblockswithlockingscrewflange.
• 3-wirelinecord.
• Illuminatedmasterpowerdisconnectcircuitbreaker
with manual reset.
Rack Dimensions:
3.25”Hx19.125”Wx8.5”D
Shipping Weight (approximate):
- Maximal33R: 14.3 lbs.
Maximal33R
Rack Mount Access Power Controller
Rev.DSMaximal33R-A19K
Overview
Specifications
Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.com
FRONT
3.125"
8.5"
.75"
19.125"
17.625"
- - - +
OUT1
- - - +
OUT2
- - - +
OUT3
- - - +
OUT4
- - - +
OUT5
- - - +
OUT6
- - - +
OUT7
- - - +
2 1
OUT8
- - - +
OUT9
- - - +
OUT10
- - - +
OUT11
- - - +
OUT12
- - - +
OUT13
- - - +
OUT14
- - - +
OUT15
- - - +
OUT16
IN1
IN2
IN3
IN5
IN6
IN7
IN8
IN4
GND
GND
GND
RESET
FACP
GND
2 1
IN14
IN15
IN16
GND
RESET
FACP
GND
GND
IN9
IN10
IN11
IN13
IN12
GND
GND
GND
TOP & BOTTOM
REAR
Maximal33R Rack Chassis Dimensions
3.25”Hx19.125”Wx8.5”D