CAME Z24-Z230 Installation guide

Type
Installation guide

CAME Z24-Z230 is a control panel for auxiliary devices that allows for the connection of operators without an RS485 terminal to management and control devices via the RS485 Bus serial cable. It features 8 inputs and 8 outputs, enabling various functionalities such as controlling lights, sirens, or sensors, and monitoring their status. Additionally, it has a built-in GSM module connector, allowing for remote communication and control.

CAME Z24-Z230 is a control panel for auxiliary devices that allows for the connection of operators without an RS485 terminal to management and control devices via the RS485 Bus serial cable. It features 8 inputs and 8 outputs, enabling various functionalities such as controlling lights, sirens, or sensors, and monitoring their status. Additionally, it has a built-in GSM module connector, allowing for remote communication and control.

FA00131-EN
English
EN
Installation manual
IO-RS485
CONTROL PANEL FOR AUXILIARY DEVICES
A B GND A B GND
L N 24V 0
OUT1 OUT2 OUT3OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
OUT8
IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8COM COM
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
GSM
FUSE
200mA
IO-RS485
BUSY
POWER
12
9
11
3
13
4
5
6
7
2
1
8
10
14
CAME
115 87
225
🅱🅰
4675
180
180
75
🅲
p. 2 - Manual code: FA00131-EN v. 2 02/2016 © CAME S.p.A.
🅳
A B GND A B GND
L N 24V 0
OUT1 OUT2 OUT3OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
OUT8
IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8COM COM
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
GSM
FUSE
200mA
IO-RS485
BUSY
POWER
PC40
RS485 *
RS485 *
IO RS485
B A 2 10
p. 3 - Manual code: FA00131-EN v. 2 02/2016 © CAME S.p.A.
Contact max. 1 A 24 V DC
Mains power supply 230 V AC 50/60 Hz
Accessories' power supply 24 V AC - 3 W max
NO or NC contact
(*) Suggested type: CAT 5 - U/UTP - AWG 24.
OFF
ON
OFF
ON
OFF
ON
n° 1
n° 7
n° 13
n° 19
n° 25
n° 31
n° 2
n° 8
n° 14
n° 20
n° 26
n° 32
n° 5
n° 11
n° 17
n° 23
n° 29
n° 6
n° 12
n° 18
n° 24
n° 30
n° 3
n° 9
n° 15
n° 21
n° 27
n° 4
n° 10
n° 16
n° 22
n° 28
🅵
🅴 🅶
p. 4 - Manual code: FA00131-EN v. 2 02/2016 © CAME S.p.A.
p. 5 - Manual code: FA00131-EN v. 2 02/2016 © CAME S.p.A.
Warnings
Only skilled, qualified staff must install this product.
Only install this product in the prescribed manner.
LEGEND
Parts to read carefully.
Parts about safety.
The measuremenTs, unless oTherwise sTaTed, are in millimeTers.
DESCRIPTION
Interface card for connecting operators that are not fitted with
the RS485 terminal to management and control devices via
the RS485 Bus serial cable.
Dimensions 🅰
Technical data
Type
Protection rating (IP) 54
Power supply (V - 50/60 Hz) 230 AC
Power supply to accessories (V) 24 AC
Standby consumption (mA) 41
Maximum power (W) 11
Contact range (A) 1
Insulation class III
Casing material ABS
Operating temperature (°C) -20 ÷ +55
Description of parts 🅱
1. Terminals for RS485 serial Bus connections
2. Terminals for connecting operators (NO contact). Contact
rated for max. 1A 24 V DC
3. Terminals for connecting control devices
4. Power supply terminal
5. Accessories power supply terminal
6. Line fuse 200 mA
7. Accessories fuse 200 mA
8. DIP switch for selecting the I/O card ID
9. DIP SWITCHES for fitting the terminal resistance
10. GREEN LED power-supply on
11. GREEN LED communication underway over serial Bus
12. RED LED for signaling that output is active
13. GREEN LED for signaling that input is active
14. GSM module connector.
p. 6 - Manual code: FA00131-EN v. 2 02/2016 © CAME S.p.A.
GENERAL INSTALLATION GUIDELINES
Preliminary checks
Before beginning, do the following:
make sure the fastening points and the anchoring surface
are solid and protected from impacts. Only use suitable nuts,
bolts, dowels, and so on;
make sure you have set up a suitable dual pole cut o device
along the power supply that is compliant with the installation
rules. It should completely cut o the power supply according
to category III surcharge conditions (that is, with minimum
contact openings of 3 mm);
make sure that any connections inside the container (ones
that ensure continuity to the protection circuit) are fitted with
additional insulation with respect to those of other electrical
parts inside: set up suitable tubes and conduits for the electric
cables to pass through, making sure they are protected from
any mechanical damage.
Cable types and minimum thicknesses
Connection Cable type Cable length
1 < 10 m
Power supply to control
panel 230 V H05RN-F 2 x 1.5 mm2
Power supply to
accessories
FROR CEI
20-22
CEI EN
50267-2-1
2 x 0.5 mm2
Command and safety
device 2 x 0.5 mm2
Serial Bus with RS485
communication standard CAT5 1200 m
If cable lengths differ from those specified in the table,
establish the cable sections depending on the actual power
draw of the connected devices and according to the provisions
of regulation CEI EN 60204-1.
INSTALLATION 🅲
Fasten the container base to a protected area, using suitable
tools .
Do not damage the card inside the container.
Drill carefully on the pre-marked Ø 20 holes . Fit the cable glands
with the corrugated tubes for threading the electrical cables .
p. 7 - Manual code: FA00131-EN v. 2 02/2016 © CAME S.p.A.
ELECTRICAL CONNECTIONS AND PROGRAMMING 🅳
Before proceeding, cut off the main power supply.
DIP SWITCHES for fitting the terminator resistor 🅴
The terminator resistor is used to balance the Bus cable over long
distances. Normally the resistor is fitted to the last devices (the
farthest) connected along the bus line.
To plug the terminator resistor set DIP switch 2 to ON (2 OFF is
the default setting).
Setting the DIP switches on the interface card 🅵
The DIP switch is set for selecting the I/O card's ID and
assigning a univocal address to the device connected on the
serial Bus.
FINAL OPERATIONS 🅶
Once the electrical connections are done fasten the cover using
the screws.
DISMANTLING AND DISPOSAL
Always make sure you comply with local laws before
dismantling and disposing of the product.
DO NOT DISPOSE OF IN NATURE!
The contents of this manual may be changed at any time without
prior notice.
REGULATORY REFERENCES
The product in question complies with the regulations referred
to in the declaration of conformity.
www. came.com
Came S.p.A.
Via Martiri Della Libertà, 15 Via Cornia, 1/b - 1/c
31030 Dosson di Casier
Treviso - Italy
33079 Sesto al Reghena
Pordenone - Italy
(+39) 0422 4940
(+39) 0422 4941
(+39) 0434 698111
(+39) 0434 698434
s a f e t y & c omfort
English - Manual code: FA00131-EN v. 2 02/2016
© CAME S.p.A. - The manual's contents may be edited at any time without
notice.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

CAME Z24-Z230 Installation guide

Type
Installation guide

CAME Z24-Z230 is a control panel for auxiliary devices that allows for the connection of operators without an RS485 terminal to management and control devices via the RS485 Bus serial cable. It features 8 inputs and 8 outputs, enabling various functionalities such as controlling lights, sirens, or sensors, and monitoring their status. Additionally, it has a built-in GSM module connector, allowing for remote communication and control.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI