Floodlight XLS
9
Installation Guide
Important: Connecting the conductors to the
wrong terminals will produce a short circuit in the
unit or your fuse box at a later stage when you
turn on the power. In this case, you must identify
the individual cables and re-connect them.
Dear Customer,
Thank you for purchasing AZ e-lite AZPOSE XL-S LED Sensor Floodlight. Please read the instructions
carefully before installing the AZPOSE Floodlight to ensure long-lasting, reliable and smooth operation.
Principle
The AZPOSE XL-S is a motion sensor controlled
LED oodlight for various indoor/outdoor
applications such as illumination of walkway, car
porch, garden and low usage areas. It can also be
programmed to operate during low light level.
Safety warnings
Disconnect the power supply before installing
the oodlight.
Installing the light involves working on the
mains power supply. Please engage professional
electrician for the installation to avoid any risk
of electrocution. Please familiarise yourself with
these instructions before attempting to install
the oodlight.
Suitable for outdoor and indoor use.
This oodlight is intended for wall mounting
only.
Motion sensor coverage range is determined
by the mounting height of the XL-10S/XL-25S
oodlight. To obtain the maximum reach of 12m,
the sensor should be installed at a height of 2.5m
- 3m. Install the unit on a rm surface to avoid
unintentional triggering.
The mains supply lead is a 3-core cable.
L = phase conductor (usually black or brown)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
Installation
Motion detectors will detect motion which
triggers the XL-10S/XL-25S to turn on. The XL-10S/
XL-25S can also turn on secondary devices such
as burglar alarms* or other lighting xtures when
triggered.
* Note that not all burglar alarms may be supported. To ensure
maximum motion detection, install the oodlight with the sensor
aimed across the direction in which a person would walk and
make sure the line of sensor vision is not obstructed.