Hunter Fan 80204 is a versatile bath ventilator with light, designed to improve air quality and provide illumination in bathrooms and other humid areas. It features a powerful motor and blower that efficiently removes moisture, odors, and pollutants, helping to prevent mold and mildew growth. The integrated light fixture provides ample illumination, making it a practical choice for bathrooms and other spaces where both ventilation and lighting are needed.

Hunter Fan 80204 is a versatile bath ventilator with light, designed to improve air quality and provide illumination in bathrooms and other humid areas. It features a powerful motor and blower that efficiently removes moisture, odors, and pollutants, helping to prevent mold and mildew growth. The integrated light fixture provides ample illumination, making it a practical choice for bathrooms and other spaces where both ventilation and lighting are needed.

42942-01 02/07/2008
1
I n s t a l l a t i o n G u i d e
80204 Bath Ventilator with Light
READ and SAVE THESE INSTRUCTIONS
ENGLISH
See page 2
ESPOL
Vea la gina 41
FRANCAIS
Voir la page 21
42942-01_2.7.08_Arial.indd 1 2/7/08 11:40:06 AM
42942-01 02/07/2008
2
DISCONNECT ELECTRIC
POWER SUPPLY
AND LOCK OUT
SERVICE PANEL BEFORE
SERVICING UNIT
W A R N I N G
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor/blower bearing damage and noisy/unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
3. DO NOT install this product in a wall. This product is designed
for installation in ceilings up to a 12/12 pitch (45 degrees).
Ductwork must point upward.
4. Pleasereadspecicationlabelonproductforfurtherinformation
and requirements.
PREVENTATIVE MAINTENANCE
A clean fan provides better service. Disconnect the power supply
and clean the fan as listed below.
TO CLEAN GRILLE: Use a mild detergent, such as dishwashing
liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool
pads or scouring powders.
TO CLEAN FAN ASSEMBLY:
Unplug motor/blower cord from recep-
tacle. To remove motor/blower, find the single tab on the motor/blower
(located next to the receptacle). Push up rear motor/blower tab while
pushing out on the side of the housing or insert a screwdriver into the
slot in the housing (next to tab) and twist screwdriver. Gently vacuum
fan, motor/blower and interior of housing.
METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED
IN WATER.
MAINTENANCE
The motor/blower is permanently lubricated and never needs oiling.
If the motor/blower bearings are making excessive or unusual noises,
replace the motor/blower with the exact service motor/blower. You
should replace the impeller at the same time.
C A U T I O N
W A R N I N G
1. Use this unit only in a manner intended by the manufacturer.
If you have questions, contact the manufacturer.
2. Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualiedperson(s)inaccordancewithallapplicable
codesandstandards,includingre-ratedconstruction.
4. Sufcientairisneededforpropercombustionandexhausting
ofgassesthroughtheue(chimney)offuelburningequipment
to prevent backdrafting. Follow the heating equipment manufac-
turer’s guideline and safety standards,such as those published
by the National Fire Prevention Association (NFPA), and the
American Society for Heating, Refrigeration and Air-Conditioning
Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall(s) or ceiling, do not damage
electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) – protected branch circuit.
8. Never place a switch where it can be reached from a tub or
shower.
9. Installfanatleast5feet(1.52m)abovetheoor.
10. This unit must be grounded.
11. Unit must not be installed in a ceiling thermally insulated to a
value greater than R40.
Do Not Install Above
Or Inside This Area
Cooking
Equipment
Floor
45° 45°
COOKING AREA
42942-01_2.7.08_Arial.indd 2 2/7/08 11:40:06 AM
42942-01 02/07/2008
3
D
E
F
G
H
I
L
M
N
x4
*
*
*
NOTE:
Strain relief cable
connector must be
installed. Not Included.
A
B
C
95044-01-000
95029-01-000
75191-01-000
03242-07-133
95491-01-000
74508-03-133
95583-01/02/03/04-000
J
77521-01
K
65219
75184-01-133
94990-02-NL
Extra Screws
x2
I
3/8 in. Cable Connector
x2
Motor/Blower
Screws
Light Fixture
Strain Relief Bracket Screw
Strain Relief Bracket
Thumbscrews
Glass Dome
Housing
Wiring Cover
Wiring Cover Screw
Mounting Rails
1
Turn off the power source.
Tools Needed. (Not supplied)
Estimated assembly time: 30 to 60 minutes
Before Installation
Check all the parts.
If damaged, call
1-866-405-3814
for replacements.
Included.
2
E
I
Loosen screws.
NOTE: Remove all packing materials before installation.
42942-01_2.7.08_Arial.indd 3 2/7/08 11:40:08 AM
42942-01 02/07/2008
4
5
4
7
G
8
F
Remove the motor/blower from the housing.
H
E
3
Remove the pre-loaded screw tip covers.
Remove the wiring cover screw.
6
Back out the pre-loaded screw tips until flush
with the side of the housing.
Remove the wiring cover.
Remove packing material.
42942-01_2.7.08_Arial.indd 4 2/7/08 11:40:11 AM
42942-01 02/07/2008
5
9
E
Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and
secure with the washer.
Position the correct depth mark at the bottom edge of the
joist based on the thickness of your sheetrock.
New Construction - attaching to joist
10
B
C
Choose Installation Option
For New Construction - attaching to joist go to step A1, page 5
For New Construction - suspended between joists go to step B1, page 8
For Existing Construction - accessible from above go to step C1, page 11
For Existing Construction - accessible only from below go to step D1, page 15
A1
E
5/8
1/2
5/8
1/2
A2
Screw pre-loaded screws into joist or framing.
42942-01_2.7.08_Arial.indd 5 2/7/08 11:40:13 AM
42942-01 02/07/2008
6
A
3 Pin
2 Pin
Fan Motor
Light
Light
Green
Black
Black
White
Black
Black
White
White
Bare Copper
Ground
A4
Main Switch 1 (AC In)
Switch 2 (AC In)
*Option Fan & Main Light Together
*Option
A3
Pull wires through the strain relief.
Connect wires as shown.
0
A6
A5
E
G
Install the wiring cover plate. Make sure all
wiring connections are inside the box or under
the wiring cover plate.
Connect 4 in. duct and vent to the outside. Tape joints.
If ducting does not fit securely, an adapter may need
to be purchased.
42942-01_2.7.08_Arial.indd 6 2/7/08 11:40:15 AM
42942-01 02/07/2008
7
A9
I
Secure the motor/blower by tightening the 2 screws.
Connect wiring harness. DO NOT ALLOW THE
MOTOR/BLOWER TO HANG FROM THE WIRING HARNESS.
Reinstall the motor/blower by inserting the tabs and
pushing up into position. Make sure the wires are not
pinched between the motor/blower and the housing.
ON
OFF
A11
Test the motor/blower. If the motor/blower does not run,
check the plug connection.
0000
H
A8
0000
A7
A10
Turn on the power source.
A12
E1
Go to step
on page 17
to attach grille.
42942-01_2.7.08_Arial.indd 7 2/7/08 11:40:19 AM
42942-01 02/07/2008
8
B1
D
E
5/8
1/2
5/8
1/2
B2
1/8 in. Bit
B4
B6
E
B3
Slide the mounting rails into brackets.
Mark position of screws by using holes as a template.
Insert screws, leaving space between the screw
head and the joist. Screws are not provided.
New Construction suspended between joists
Position the correct depth mark at the bottom edge of
the joist based on the thickness of your sheetrock.
Drill a hole in the center of each outline.
Attach the rails onto the screws.
42942-01_2.7.08_Arial.indd 8 2/7/08 11:40:22 AM
42942-01 02/07/2008
9
Tighten screws. Pull wires through the strain relief.
Connect wires as shown.
B7
B8
A
3 Pin
2 Pin
Fan Motor
Light
Light
Green
Black
Black
White
Black
Black
White
White
Bare Copper
Ground
B9
Main Switch 1 (AC In)
Switch 2 (AC In)
*Option Fan & Main Light Together
*Option
B11
Install the wiring cover plate. Make sure all wiring
connections are inside the box or under the
wiring cover plate.
F
G
B10
Connect 4 in. duct and vent to the outside. Tape joints.
If ducting does not fit securely, an adapter may need
to be purchased.
42942-01_2.7.08_Arial.indd 9 2/7/08 11:40:25 AM
42942-01 02/07/2008
10
B17
E1
Go to step
on page 17
to attach grille.
B12
H
Connect wiring harness. DO NOT ALLOW THE
MOTOR/BLOWER TO HANG FROM THE WIRING HARNESS.
H
B13
Reinstall the motor/blower by inserting the tabs and
pushing up into position. Make sure the wires are not
pinched between the motor/blower and the housing.
B15
Turn on the power source.
ON
OFF
B16
B14
I
Secure the motor/blower by tightening the 2 screws.
Test the motor/blower. If the motor/blower does not run,
check the plug connection.
42942-01_2.7.08_Arial.indd 10 2/7/08 11:40:29 AM
42942-01 02/07/2008
11
C2
D
E
Existing Construction accessible from above
EXISTING FAN
C1
NO EXISTING FAN
8 in.
8.5 in
.
OR
Remove an existing fan and check to make sure the
opening is large enough to accommodate the new
motor/blower housing (8 in. x 8.5 in.).
Cut out an opening for the housing.
Use the motor/blower housing as a
template to mark position.
Slide the mounting rails into brackets.
Position the correct depth mark at the bottom edge of the
joist based on the thickness of your sheetrock.
5/8
1/2
5/8
1/2
C3
C4
Mark position of screws by using holes as a template.
42942-01_2.7.08_Arial.indd 11 2/7/08 11:40:31 AM
42942-01 02/07/2008
12
C7
C8
C9
C10
C5
1/8 in. Bit
C6
Drill a hole in the center of each outline. Insert screws, leaving space between the screw head
and the joist. Screws are not provided.
Attach the rails onto the screws. Tighten screws.
Connect 4 in. duct and vent to the outside. Tape joints.
If ducting does not fit securely, an adapter may
need to be purchased.
Pull wires through the strain relief.
42942-01_2.7.08_Arial.indd 12 2/7/08 11:40:35 AM
42942-01 02/07/2008
13
C11
A
3 Pin
2 Pin
Fan Motor
Light
Light
Green
Black
Black
White
Black
Black
White
White
Bare Copper
Ground
C12
Main Switch 1 (AC In)
Switch 2 (AC In)
*Option Fan & Main Light Together
*Option
Tighten the strain relief screws.
Connect wires as shown.
C14
H
G
F
C13
Install the wiring cover. Make sure all wiring connections are
inside the box or under the wiring cover.
Connect wiring harness. DO NOT ALLOW THE MOTOR/
BLOWER TO HANG FROM THE WIRING HARNESS.
42942-01_2.7.08_Arial.indd 13 2/7/08 11:40:37 AM
42942-01 02/07/2008
14
C15
H
C16
I
C17
ON
OFF
C18
Secure the motor/blower by tightening the 2 screws.
Turn on the power source. Test the motor/blower. If the motor/blower does not run,
check the plug connection.
C19
E1
Go to step
on page 17
to attach grille.
Reinstall the motor/blower by inserting the tabs and pushing
up into position. Make sure the wires are not pinched
between the motor/blower and the housing.
42942-01_2.7.08_Arial.indd 14 2/7/08 11:40:40 AM
42942-01 02/07/2008
15
EXISTING FAN
D1
E
D2
Existing Construction accessible only from below
D3
2
1
D4
Pull wires through strain relief.
Remove an existing fan and check to make sure the
opening is large enough to accommodate the new
motor/blower housing (8 in.x 8.5 in.).
Move the housing into position above the ceiling.
Attach existing ducting to duct connector. Tape joints.
If ducting does not fit securely,
an adapter may need to be purchased.
E
D5
Screw pre-loaded screws into joist or framing.
42942-01_2.7.08_Arial.indd 15 2/7/08 11:40:43 AM
42942-01 02/07/2008
16
A
3 Pin
2 Pin
Fan Motor
Light
Light
Green
Black
Black
White
Black
Black
White
White
Bare Copper
Ground
D6
Main Switch 1 (AC In)
Switch 2 (AC In)
*Option Fan & Main Light Together
*Option
H
D8
H
D9
D10
I
Connect wires as shown.
Reinstall the motor/blower by inserting the tabs and
pushing up into position. Make sure the wires are not
pinched between the motor/blower and the housing.
Connect wiring harness. DO NOT ALLOW THE MOTOR/
BLOWER TO HANG FROM THE WIRING HARNESS.
Secure the motor/blower by tightening the 2 screws.
F
D7
G
Install the wiring cover plate. Make sure all wiring
connections are inside the box or under
the wiring cover plate.
42942-01_2.7.08_Arial.indd 16 2/7/08 11:40:46 AM
42942-01 02/07/2008
17
ON
OFF
D12
D13
E1
Go to step
on page 17
to attach grille.
D11
Test the motor/blower. If the motor/blower does not run,
check the plug connection.
Turn on the power source.
Attaching the Grille
Remove the thumbscrews. Connect wiring harness.
M
E
E1
L
E2
42942-01_2.7.08_Arial.indd 17 2/7/08 11:40:49 AM
42942-01 02/07/2008
18
Insert the strain relief bracket’s dog-leg tab so that
it hooks over the lip of the motor. Reinstall the
strain relief bracket screw.
E5
Position the strain relief bracket under the motor as shown.
E4
J
Remove the strain relief bracket screw.
E3
K
Install 2 Max 60 watt A-15 bulbs (Not Included).
E8
Attach thumbscrews.
WARNING: To reduce the risk of electrical shock,
all 4 thumbscrews MUST be properly installed.
M
E7
Align posts A, B, C and D (stamped into motor housing) with
posts A, B, C and D (stamped into light fixture). Slide light
fixture over posts.
L
E6
42942-01_2.7.08_Arial.indd 18 2/7/08 11:40:52 AM
42942-01 02/07/2008
19
E10
Screw glass dome into position.
Troubleshooting
Problem: Fan does not come on.
Solution:
 •HarborBreezeFanBathVentilatorsareextremelyquiet.Toconrmthatthefanisrunning,placeyourhand
near the vents to feel the air movement.
• Turn power on, replace fuse, or reset breaker.
• Check all plug connections to be sure they are secure.
• Check the wiring to make sure it matches the wiring diagram.
Problem:
Light does not come on.
Solution:
Replace the light bulb with a new bulb.
Turn power on, replace fuse, or reset breaker.
Check all plug connections to be sure they are secure.
Check the wiring to make sure it matches the wiring diagram.
Problem: Fan is noisy.
Solution:
Check and tighten all fasteners.
Check the glass to make sure it is secure.
 •Checktheappertomakesureitmovesfreely.
If you need parts or service assistance, please call 866-405-3814.
Align glass dome and push up.
N
E9
42942-01_2.7.08_Arial.indd 19 2/7/08 11:40:53 AM
42942-01 02/07/2008
20
Warranty
Harbor Breeze
Bath Exhaust Fan
LIMITED WARRANTY
The manufacturer makes the following limited warranty to the original user or consumer purchaser of this Harbor Breeze bath
exhaust fan:
IfanypartofyourHarborBreezebathexhaustfan(exceptforglassxturesandlightbulbs)failsatanytimewithinoneyear
after the date of sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the defective part
free of charge. After this one-year period, you will be responsible for all parts and labor costs for repairs on the bath exhaust fan
except for motor repairs as provided below.
IfyourHarborBreezebathexhaustfanmotorfailsatanytimewithinveyearsafterthedateofsaletoyouduetoadefectin
material or workmanship, labor and materials to repair the defect will be provided free of charge. If no replacement part can be
provided, we will, at our option, either refund the actual purchase price of your bath exhaust fan or provide a replacement free of
charge.Afterthisve-yearperiod,youwillberesponsibleforallpartsandlaborcostsforrepairsonallpartsofthebathexhaust
fan.
IF THE ORIGINAL USER OR CONSUMER PURCHASER CEASES TO OWN THE FAN, THIS WARRANTY AND ANY IMPLIED
WARRANTY WHICH THEN REMAINS IN EFFECT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MER-
CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE VOIDED. NO WARRANTY, EXPRESS OR IMPLIED, IN-
CLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS MADE IN RESPECT
OF GLASS FIXTURES OR LIGHT BULBS OR THE FINISH ON ANY METAL PORTION OF THE BATH EXHAUST FAN.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY,
INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, IN RESPECT TO ANY HARBOR BREEZE BATH EXHAUST FAN MOTOR OR OTHER FAN PART, IS EXPRESSLY
LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH MOTORS OR OTHER PARTS.
This warranty is voided if your Harbor Breeze bath exhaust fan is not purchased and installed in the U.S.A. This warranty
excludes and does not cover defects, malfunctions or failures of any Harbor Breeze bath exhaust fan which were caused by
repairs by persons not authorized by us, use of parts or accessories not authorized by us, mishandling, improper installation,
modicationsordamagetotheHarborBreezebathexhaustfanwhileinyourpossession,orunreasonableuse,includingfailure
to provide reasonable and necessary maintenance.
To obtain servicing, contact the Harbor Breeze Service Department at 1-866-405-3814. Please contact us before shipping your
bath exhaust fan to us. If we authorize you to ship it to us, you will be responsible for all insurance and freight or other transpor-
tation charges to our factory or service center. We will return your Harbor Breeze bath exhaust fan freight prepaid. Your Harbor
Breeze bath exhaust fan should be properly packed to avoid damage in transit since we will not be responsible for any such
damage. Proof of purchase is required when requesting warranty service. The purchaser must present the sales receipt or other
document that establishes proof of purchase.
IN NO EVENT SHALL THE MANUFACTURER BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES.
SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR
LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSIONS MAY NOT
APPLY TO YOU.
THE WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM
STATE TO STATE.
Printed in China
© 2008 Hunter Fan Company
42942-01_2.7.08_Arial.indd 20 2/7/08 11:40:53 AM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Hunter Fan 80204 Owner's manual

Type
Owner's manual

Hunter Fan 80204 is a versatile bath ventilator with light, designed to improve air quality and provide illumination in bathrooms and other humid areas. It features a powerful motor and blower that efficiently removes moisture, odors, and pollutants, helping to prevent mold and mildew growth. The integrated light fixture provides ample illumination, making it a practical choice for bathrooms and other spaces where both ventilation and lighting are needed.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI