Cooper Lighting 120/277 Ultrasonic Wall Switch Sensor Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Cooper Lighting 120/277 Ultrasonic Wall Switch Sensor Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation Instructions
Eaton’s Cooper Controls Business
203 Cooper Circle
Peachtree City, Georgia 30269
www.coopercontrol.com
SuperSwitch® Ultrasonic Wall Switch
120/277 VAC
• Readallinstructionsonbothsidesofthissheet
rst
• Planallcomponentlocationscarefully
• Installinaccordancewithalllocalcodes
• Onemodelforeither120VACor277VAC
• Notforusewheretemperaturesfallbelow32°For
exceed100°F
• Forindooruseonly
• NoleakagetoloadinOFFmode
Technology:Ultrasonic
Electrical Ratings:
120VAC:
• Incandescent/Tungsten–Max.load:6.7amps,
800W,60Hz
• Fluorescent/Ballast–Max.load:6.7amps,800W,
60Hz
MotorLoad:¼HP@125VAC
277VAC:
• Fluorescent/MagneticBallast–Max.load:4.3
amps,1200W,60Hz
Ballast Compatibility:Compatiblewithmagneticballasts
No Minimum Load Requirement
Time Delays:15secondsto15minutes
Coverage:Majormotion–500sq.ft.
Minormotion300sq.ft.
Operating Environment:
• Temperature:60°F–80°F(15°C–26°C)
• RelativeHumidity:Lessthan95%non-condensing
Forindooruseonly
Housing:Durable,injectionmoldedhousing.ABSresin
complieswithUL94V-O.
Size:
• MountingPlateDimensions:
4.15”Hx1.94”W(105.41mmx49.28mm)
• ProductHousingDimensions:
2.73”Hx1.8”Wx1.8”D
(69.34mmx45.72mmx45.72mm)
LED Indicators:RedLEDforUltrasonicdetection
OSW-U-0721-MVisaself-contained
motion-sensinglightingcontroldevicethatreplacesaconventionalwall
switchforenergysavingsandconvenience.Built-insensorsproducelowintensity,inaudiblesoundanddetect
changesinsoundwavescausedbymotion,suchaswalkingintotheroom,reachingforatelephone,turningina
chair.Thesensordoesnotrespondtoaudiblesound.LightsturnOFFautomaticallyafteraroomisvacated.
ThedeviceoffersachoiceofAutomaticONorManualONmodes.IntheAutomaticONmode,thelightsturn
ONautomaticallywhenapersonenterstheroom.IntheManualONmode,lightsareturnedONbypressingthe
touchplateONtheswitch.Modescanbechangedbyflippingtheconcealedswitchunderthetouchplate.
(SeeCheckoutandAdjustment).Ineithermode,lightswillremainONaslongasmotionisdetectedintheroom.
Whennomotionisdetected,thelightswillturnOFFautomaticallyafterthepre-settimedelay.Followingthis,a
“graceperiod”ofapproximatelytensecondsallowslightstobeturnedONagainbymotion.
Atanytime,lightsmaybeturnedOFFwhiletheroomisoccupiedbypressingthetouchplate.OSW-U-0721-MVis
fullyself-resetting;lightsturnedOFFmanuallyinAutomaticONmode
willstayOFFwhiletheroomremainsoccupied.
Aftertheroomisvacatedandthepre-settimedelayandgraceperiodhaveelapsed,thelightswillremainOFFuntil
turnedONautomaticallythenexttimesomeoneenterstheroom.
OSW-U-0721-MVcanbeusedwithastandardtoggleswitchtosplitthelightingloadforroomsthatarewiredfor
twoswitchesasshownintheWiringDiagram.
P/N 9850-000408-00
Description
Specifications
General Information
Model # OSW-U-0721-MV-A
Model # OSW-U-0721-MV-V
Model # OSW-U-0721-MV-W
CAUTION: Before installing or performing any service on a Greengate system, the power MUST be turned OFF at
the branch circuit breaker. According to NEC 240-83(d), if the branch circuit breaker is used as the main switch
for a fluorescent lighting circuit, the circuit breaker should be marked “SWD. All installations should be in
compliance with the National Electric Code and all state and local codes.
NOTE REGARDING COMPACT FLUORESCENT LAMPS: The life of some compact fluorescent lamps (CFLs) is
shortened by frequent automatic or manual switching. Check with CFL and ballast manufacturer to determine the
effects of cycling.
CAUTION: Model OSW-U-0721-MV is for use with either 120 VAC or 277 VAC only. For other voltages refer to
product spec sheet. Do not wire to control receptacle circuits.
VERIFYthattheconnectedloaddoesnotexceedtheOSW-U-0721-MVratings.Thereisnominimumload
requirement.Usetwist-onwireconnectorsforallconnections.ModelOSW-U-0721-MVcanbewiredtocontrol
bothanexhaustfanandlightingprovidedthetotalloaddoesnotexceedthemaximumloadrating(inAmps)forthe
automaticwallswitch.
1. Connectthewhiteleadtotheneutral.
2. ConnecttheredleadtotheswtichlegforLoad1andtooneterminalofthetoggleswitch.
3. ConnecttheothertoggleswitchterminaltotheswitchlegforLoad2.
4. Connecttheblackwiretothehotlead.
Note: Connectionsarepolaritysensitive.
CAUTION: If a room is wired for two circuits using two separate hot leads, it is very important to connect only one
circuit to the OSW-U-0721-MV. Split one circuit into two switch legs and cap the unused hot lead inside the box.
The OSW-U-0721-MV must always control Load 1, while its control of Load 2 is selected manually by opening and
closing the toggle switch.
Wiring
TheOSW-U-0721-MVisdesignedforofficesupto300squarefeet.Wallswitchesarenormallymountedoff-centerin
aroomwhichreducesthecoverageattainable.
WheninstallingtheOSW-U-0721-MVinanewjunctionbox,choosetheswitchlocationcarefullytoprovideoptimum
coverageoftheoccupiedarea.Whenreplacinganexistingwallswitch,bearinmindthattheremustbeaclearlineof
sightbetweentheOSW-U-0721-MVandtheareatobecovered.AvoidpointingtheOSW-U-0721-MVdirectlyintothe
hallwaywhereitmaydetectpassers-by.
Coverage
Location
24'
(7.31m)
20'
(6.09m)
30'
(9.14m)
25'
(7.62m)
TheOSW-U-0721-MVcanreplaceoneswitchinanystandardsingleor
doublegangbox.Itmaybeinstalledinthesamemannerasanordinarywall
switch.
Forsafetypurposesbeforeinstallingordoinganyserviceonthe
OSW-U-0721-MV,thepowermustbeturnedOFFatthecircuitbreakerpanel.
WiretheOSW-U-0721-MVasdescribedinthewiringsection.
MounttheOSW-U-0721-MVinthejunctionbox.
Installation
Wiring Diagram 1: Single Level Switching
Ultrasonic
Activated
Wiring Diagram 2: Dual Level Switching using additional toggle switch
Sensor
10
15
25’
7.62m
*HOT - 120/277VAC
*HOT - 120/277VAC
*HOT
*HOT
BLACK
BLACK
RED
RED
NEUTRAL
NEUTRAL
WHITE
WHITE
LIGHTING
LOAD
LIGHTING
LOAD
LIGHTING
LOAD
30’
9.14m
24’
7.31m
20’
6.09m
Eaton’s Cooper Controls Business
203 Cooper Circle
Peachtree City, Georgia 30269
www.coopercontrol.com
LED will not turn ON
Verifythatthelightingcircuithaspower.VerifythattheOSW-U-0721-MVisproperlyadjusted.Pressthe
touchplatetomanuallyturnONthelights.IfLEDdoesnotlight,replaceOSW-U-0721-MV.
Lights will not turn ON
IfthelightswillnotturnONautomaticallyaftersomeoneenterstheroom,pressthetouchplatetoseeiflights
willturnON.Ifso,theOSW-U-0721-MVcouldbesettotheManualONmode.Checkunderthetouchplatetoverify
thesetting.IfOSW-U-0721-MVissettoAutomaticONmode,itmayhavebeenoverriddenbysomeonepressing
thetouchplate;allowtheOSW-U-0721-MVtotimeouttoverifynormaloperation.IfthelightsdonotturnONafter
pressingthetouchplate,conrmthatnootherswitchesorequipmentareinterruptingorbypassingpowertothe
OSW-U-0721-MVortheload.IflightsstilldonotturnON,replacetheOSW-U-0721-MV.
Lights will not turn OFF
IfthelightswillnotturnOFFafterthetimedelayset,andtheLEDhasnotlitduringthetimeperiod,pressthe
touchplatetomanuallyturnOFFthelights.IflightsturnOFF,refertoitems5and6aboveunder“Checkoutand
Adjustment.”IflightsdonotturnOFF,verifythattheoverridejumperunderthetouchplate
hasnotbeenremoved.
ConrmthatnootherswitchesorequipmentareinterruptingorbypassingpowertotheOSW-U-0721-MVorthe
load.IflightsstilldonotturnOFF,replacetheOSW-U-0721-MV.
4. Leavetheroom.Thelightsshouldgooutinapproximately15seconds.Waitatleast12secondsafterthelights
goout.WalknormallybackintotheroomandverifythatthelightsturnONautomatically.Ifnot,the“EntryRange”
shouldbeincreasedslightly.Donotsethigherthannecessary.
5. IftheLEDblinksorstaysONwhenthereisnomovementintheroom,itispossiblethatthesensorisbeing
activatedbyairowfromtheHVACsystem.Reducethe“AreaRange”settinguntiltheLEDgoesOFFandstaysOFF
withnomotion.
6. Ifthesensorisactivatedbypassers-byinthehallway,reducethe“EntryRange”setting.
7. Set“TimeDelay”tothedesiredsettingfornormaluse.Iflightsgooutwhiletheroomisoccupied,increasesetting
slightlyuntilanoptimumintervalisobtained.Recommendedtimedelayisusually6-8minutes(approximately12
o’clockto1o’clock).Peoplewhoremainverystillforlongperiodsmayneedalongertimedelay.
8. Ifpreferred,ModelOSW-U-0721-MVcanbesettoManualONformaximumenergysavingsbymovingthe“Mode”
switchtothe“M”position.Inthissetting,occupantmustpush
thetouchplatetoturnONlightsuponenteringthe
room.
Override
AnoverridejumperislocatedunderneaththeOSW-U-0721-MVtouchplate.Thisjumpershouldremaininplaceatall
times,exceptintheeventofunitmalfunction.RemovethejumpertobypassthesensorandturnthelightsON.
Checkout and Adjustment
Pleaserefertowww.coopercontrol.comundertheLegalsectionforourtermsandconditions.
Troubleshooting
Warranties and Limitation of Liability
Wiring Diagram 3: For Three-Way Wiring
Onceinstallationiscomplete,restorepowertothelightingcircuit.ProperoperationoftheOSW-U-0721-MVmust
beveried.Controlscanthenbeadjustedfortheindividualuser.AdjustmentsshouldbemadewiththeHVACsystem
ON.
Note:Useonlyinsulatedtoolstomakeadjustments.
1. Adjustmentcontrolsareunderthetouchplate.“TimeDelay”ranges
from1/4minute(15seconds),forinstallertesting,to15minutes.
Usingasmallscrewdriver,set“TimeDelay”to1/4minutebyturning
thecontrolcompletelycounterclockwiseuntilitstopsatminimum
setting(approximately8o’clock).Turncontrolfor“AreaRange”until
atedgeofcontrolisat10o’clock.Turn“EntryRange”untilat
edgeofcontrolisat9o’clock.
2. Movethe“Mode”switchtothe“Auto”orA”position.
3. Theareaofcoveragecanbedeterminedbywatchingthe
LEDindicatoronthefrontofOSW-U-0721-MVwhilemoving
aroundtheroom.TheLEDlightsonlywhenthesensoris
detectingmotion.Adjustthe“AreaRange”controltothe
lowestsettingthatprovidesadequatemotiondetection
ofapersonworkingintheroom.Donotsethigherthannecessary.
Range
Area Entry
Time
Delay
MA
1/4 15
503
503
503
NEUTRAL
NEUTRAL
BLACK
BLACK
RED
RED
WHITE
WHITE
LOAD
TRAVELLERS
120 VAC or 277 VAC
/