IS-43011-US
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
pipe must protrude out the back of mounng strap.
Screw third hexnut onto end of threaded pipe protruding
from back of mounng strap.
7) Connect mounng strap to outlet box using the strap
mounng screws[J].
8) Unscrew the threaded ring[F] from screw collar loop.
Take canopy[G] and pass over screw collar loop.
Approximately one half of the screw collar loop exterior
threads should be exposed. Adjust screw collar loop by
turning assembly up or down in mounng strap. Remove
canopy.
9) Aer desired posion is found, ghten both top and
boom hexnuts up against the boom and top of the
mounng strap.
10) Slip canopy over screw collar loop and thread on
threaded ring. Aach chain (with xture connected) to
boom of screw collar loop. Unscrew threaded ring,
let canopy and threaded ring slip down. Aach chain to
xture if required.
11) Aach open chain link[H] to small loop at end of each
stem and to each loop on canopy and close the open
chain link.
12) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, and thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector (Not provided) aer following the above steps.
Never connect ground wire to black or white power
supply wires.
13) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (see illus.)
Neutral Wire
14) Thread on the top loop onto the tubes from the main
body and connect the open chain link and close the chain
link with a towel and a pair of pliers.
15) Raise canopy to ceiling.
16) Secure canopy in place by ghtening threaded ring onto
screw collar loop.
17) Install the recommended bulb (not supplied).
18) Raise the glass[M] up over the installed bulb and place
the basket[N] over the glass and using the two (2) ball
knobs[O] secure into place.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
[A] Threaded
Pipe
[B] Screw Collar
Loop
[C] Hexnut
[D] Mounting
Strap
[E] Outlet Box
[F] Threaded
Ring
[G] Canopy
[H] Chain Link
[I] First Loop
[J] Strap
Mounting
Screws
[K] Threaded
Tubes
[L] Coupling
[M] Glass
[N] Basket
[O] Ball Knobs
1) Pass xture wire from the coupling[L] on top of xture
through a stem[J] and threaded tubes[K] and screw
stem into coupling. NOTE: Thread locking compound
must be applied to all stem threads as noted with symbol
(4) to prevent accidental rotaon of xture during
cleaning, relamping, etc.
2) Pass xture wire through desired amount of stems and
screw stems together using supplied short threaded
tubes.
3) Pass xture wire from last stem through rst loop[I].
Thread rst loop onto end of last stem.
4) Pass xture wire through second loop and through hole
in canopy[G].
5) Take threaded pipe[A] from parts bag and screw in
screw collar loop[B] a minimum of 6 mm (1/4”). Lock
into place with hexnut[C].
6) Run another hexnut down threaded pipe almost
touching rst hexnut. Screw threaded pipe into
mounng strap[D]. Mounng strap must be posioned
with extruded thread faced into outlet box[E]. Threaded
E
D
C
J
A
G
B
F
H
►
I
J
K
►
►
►
L
N
M
P
O