inserted into the steel tube and buried into the ground, with both ends of the steel
tube properly grounded.
6. The lightning protector shall be installed nearby the premises-outgoing segment of
network cable.
7. In plain areas, the protection angle of antenna lightning arrester shall be less than
45 degree. In mountainous and high-lightning areas, the protection angle of antenna
lightning arrester shall be less than 30 degree. Devices like lightning arrester shall
share the grounding body with the equipment room.
8. The grounding resistance shall be less than 5 ohm. For places with high soil
resistivity, the resistance-reducing agent shall be sprinkled around the soil of
grounding body to reduce soil resistivity.
9. When AC power is used, the power cable with PE pin shall be used instead of
changing into 2-core power cable with only L and N lines. The N line must not be
connected to the protective ground used by other communication devices, while L
and N lines must not be reversed.
2.3 Site Selection
AP620-H shall not be installed in heated, dusty, inflammable or explosive
environment, or at sites with noxious gases, electromagnetic interference (i.e.,
nearby large-sized radar station, transmitting station, transformer substation and etc),
unstable voltage, notable vibration, or high noise. The installation site shall be dry and
far from the seaside (greater than 500m from seaside), while the device must not be
exposed to the sea wind. Do not install the device at places being prone to water
accumulation, water penetration, water dripping and dewing. During engineering
design, the installation site complying with communication equipment engineering
design requirements shall be selected according to communication network planning
and technical requirements of the subject communication equipment, as well as such
factors of climate, hydrology, geology, earthquake, power supply and transportation.
2.4 Temperature & Humidity
The operating temperature and humidity of the device are shown below:
Standard operating ambient temperature: -40℃ - 55℃
Storage temperature: -40℃ - 85℃
Working humidity (non-condensing): 5% - 95%