Ruijie RG-AP620 Series Installation guide

Category
Network switches
Type
Installation guide

Ruijie RG-AP620 Series is a wireless access point designed for demanding outdoor applications. It can serve as a Fit AP and network with wired/wireless integrated switch/wireless controller, or act as a FAT AP and provide wireless access service for WLAN users. The device has one 1 Gigabit combo port (1 10/100/1000M self-adaptive RJ45/SFP combo port), 1 console interface, and 6 antenna interfaces. It adopts POE input and complies with 802.3at protocol, with input voltage range of 36-57V and rated current of 0.57A.

Ruijie RG-AP620 Series is a wireless access point designed for demanding outdoor applications. It can serve as a Fit AP and network with wired/wireless integrated switch/wireless controller, or act as a FAT AP and provide wireless access service for WLAN users. The device has one 1 Gigabit combo port (1 10/100/1000M self-adaptive RJ45/SFP combo port), 1 console interface, and 6 antenna interfaces. It adopts POE input and complies with 802.3at protocol, with input voltage range of 36-57V and rated current of 0.57A.

·
Installation Guide
RG- AP620 Series
Wireless Access Device
Copyright statement
Ruijie Network2000-2011
Ruijie Networks reserves all copyrights of this document. Any reproduction, excerption, backup,
modification, transmission, translation or commercial use of this document or any portion of this
document, in any form or by any means, without the prior written consent of Ruijie Networks is
prohibited.
、 、
are registered trademarks of
Ruijie Networks. Counterfeit is strictly prohibited.
Exemption statement
This document is provided “as is”. The contents of this document are subject to change without any
notice. Please obtain the latest information through the Ruijie Networks website. Ruijie Networks
endeavors to ensure content accuracy and will not shoulder any responsibility for losses and damages
caused due to content omissions, inaccuracies or errors.
Preface
Thank you for using our switches. This manual will guide you through the
installation and use of switches.
Scope
This manual introduces functional and physical features of our switches and
provides installation procedures, troubleshooting, technical specifications, and
rules of using cables and connectors. It is intended for the users who have
some experience in installing and maintaining network hardware and want to
learn the above information.
This manual assumes that users are familiar with Ethernet terms and concepts.
Document Structure
Chapter 1 Product Overview describes main features, technical
specifications and related modules.
Chapter 2 Preparation Before Installation lists safety, power supply,
and site requirements that must be met before you install the switch.
Chapter 3 Installation” describes how to install the switch as a whole and
its various modules, and connect power supply and grounding cables.
Appendix A “Connectors and Connection Media”.
Appendix B Mini-GBIC Modules.
Related Documents
Software Manual for the Wirelless Access Point: Covers CLI commands,
configuration guide and version release notes.
Obtaining Documentation
You can obtain the documentation you need through the following channels:
Internet:
You can obtain the latest on-line documentation at:http://www.ruijie.com.cn
Documentation CD-ROM:
The documentation of Ruijie Networks switches is stored in the CD-ROM
package, which is provided to you together with the product you purchase. The
CD-ROM is updated frequently, and may be more current than the printed
documents.
Obtaining Technical Assistance
Ruijie Networks provides excellent technical support services for all our
products. You can obtain the technical assistance you need through any of the
following channels:
Ruijie Networks website, from which you can obtain the latest product
documentation, causes and problems analysis of product faults,
application solutions, and software upgrade. http://www.ruijie.com.cn/
Ruijie Networks advisory services: Enter the Ruijie official website, and
then click the “Advisory Services.
Customer service center of Ruijie Networks, which can provide all
customers with needed technical assistance for products, technologies and
solutions. The customer service center provides responsive technical
support for your product installation problems, software configuration
problems, and other network performance problems.
http://www.ruijie.com.cn/service.aspx
Customer services hotline: +86-4008-111-000
Customer services email: [email protected].cn
Documentation Conventions
The symbols used in this document are described as below:
Note
This symbol brings your attention. It includes some helpful suggestions and
references.
Warning
This symbol means that you must be extremely careful. It reminds you to
avoid behaviors that can bring data loss and cause damage to a device.
1 Product Overview
1.1 Introduction
Ruijie RG-AP620-H WLAN Access Point (hereafter referred to as AP620-H) is one of
the wireless AP products independently developed by Fujian Ruijie Networks Co., Ltd.
AP620-H is mainly designed for demanding outdoor applications. Besides serving as
Fit AP and networking with wired/wireless integrated switch/wireless controller, it can
also act a FAT AP and provide wireless access service for WLAN users.
1.2 Key Technical Indicators
of RG-AP620-H
Table 1-1 Technical indicators of AP620-H wireless AP
Model No.
RG-AP620-H
Application
Outdoor high-power wireless AP
Interface
1 Gigabit combo port (i.e., 1 10/100/1000M
self-adaptive RJ45/SFP combo port); 1 console
interface and 6 antenna interfaces
Power
system
Input
POE power supply, 802.3at protocol
Source power
25W
Power supply redundancy
Unsupported
Reliability
Fanless
Management
board
CPU
CN5010 500MHz
Memory
256M
Parallel flash
2MB
Serial flash
128MB
Radio
management
(wireless)
Automatic control of AP
power
See left
Automatic channel
switchover
AP load sharing
Environmental requirement
Normal operations can be achieved at ambient
temperature of -40 - 55 and without water
immersion.
1.3 Detailed Introduction to
AP620-H Wireless AP
1.3.1 AP620-H Wireless AP
1.3.1.1 Physical Appearance
The front panel of AP620-H provides one 10/100/1000M self-adaptive RJ45/SFP
combo interface, 1 Console interface, and 3 N-type antenna interfaces on both sides,
with appearance shown below:
Fig 1-1 Physical appearance of AP620-H
1.3.1.2 Front Panel
Fig 1-2 Front panel of RG-AP620-H
1. Console interface
2. 1000Base-X SFP port
3. 10/100/1000Base-T self-adaptive Ethernet port
1.3.1.3 Power System
AP620-H adopts POE input and complies with 802.3at protocol.
Input voltage range: 36-57V
Rated current: 0.57A
1.3.1.4 Cooling System
RG-AP620-H adopts fanless design.
2 Preparations Before Installation
2.1 Safety Precautions
To avoid the harms caused to human and device, please carefully read the safety
precautions given in this manual before installing RG-AP620-H.
The following safety precautions can't cover all possible hazardous
conditions.
2.2 Grounding and Lightning
Protection
1. Grounding body
The grounding body shall adopt hot-galvanized flat steel (or copper), with dimension
no less than 40mm*4mm. The vertical grounding body shall adopt
50mm*50mm*5mm (minimum) hot galvanized angle bar with length reaching 2.5m; in
case steel tube is used, the wall thickness must reach at least 3.5mm.
2. Ground lead
The ground lead shall adopt 40mm * 4mm or 50mm * 5mm hot-galvanized flat steel
with length no exceeding 30m.
3. Grounding bus bar
The grounding bus bar shall be generally copper bar with cross-sectional area no
less than 160mm2. The vertical grounding trunk for high-rise buildings shall adopt
copper bar with cross-sectional area no less than 300mm2.
4. If the distance between the grounding bus bar of respective floors and the
connecting wire of Local Expansion Bus (LEB) of equipment room is rather short,
multi-strand copper wire with cross-sectional area being 16mm2 can be used; if the
distance is long, multi-strand copper wire with cross-sectional area no less than
35mm2 must be used.
5. The network cable shall adopt shielded cables and devices at both ends shall be
reliably grounded, while the shielding jacket of network cables shall be grounded as
possible. If network cables cannot be shielded as required, the cables can be
inserted into the steel tube and buried into the ground, with both ends of the steel
tube properly grounded.
6. The lightning protector shall be installed nearby the premises-outgoing segment of
network cable.
7. In plain areas, the protection angle of antenna lightning arrester shall be less than
45 degree. In mountainous and high-lightning areas, the protection angle of antenna
lightning arrester shall be less than 30 degree. Devices like lightning arrester shall
share the grounding body with the equipment room.
8. The grounding resistance shall be less than 5 ohm. For places with high soil
resistivity, the resistance-reducing agent shall be sprinkled around the soil of
grounding body to reduce soil resistivity.
9. When AC power is used, the power cable with PE pin shall be used instead of
changing into 2-core power cable with only L and N lines. The N line must not be
connected to the protective ground used by other communication devices, while L
and N lines must not be reversed.
2.3 Site Selection
AP620-H shall not be installed in heated, dusty, inflammable or explosive
environment, or at sites with noxious gases, electromagnetic interference (i.e.,
nearby large-sized radar station, transmitting station, transformer substation and etc),
unstable voltage, notable vibration, or high noise. The installation site shall be dry and
far from the seaside (greater than 500m from seaside), while the device must not be
exposed to the sea wind. Do not install the device at places being prone to water
accumulation, water penetration, water dripping and dewing. During engineering
design, the installation site complying with communication equipment engineering
design requirements shall be selected according to communication network planning
and technical requirements of the subject communication equipment, as well as such
factors of climate, hydrology, geology, earthquake, power supply and transportation.
2.4 Temperature & Humidity
The operating temperature and humidity of the device are shown below:
Standard operating ambient temperature: -40 - 55
Storage temperature: -40 - 85
Working humidity (non-condensing): 5% - 95%
2.5 Outdoor Installation
RG-AP620-H WLAN AP is designed for direct outdoor installation and supports
wall-mount installation and pole-mount installation.
2.6 Waterproof Considerations
1. For unused interfaces, the corresponding waterproof plugs shall be processed (use
waterproof tape to rewind the screw thread of waterproof plug for three loops), and
then seal the unused interfaces with waterproof plugs.
2. After completing the installation of external cables, use waterproof tape to rewind the
cable to ensure the waterproof effect.
2.7 EMI Considerations
Various interference sources, no matter from inside or outside of the device or
application system, will have impacts on the device through capacitive coupling,
inductive coupling and electromagnetic wave radiation.
Electromagnetic interference can be divided into radiated interference and conducted
interference, which will be determined according to the type of transmission path.
Radiated interference is incurred when the energy (usually the RF energy)
transmitted by a component reaches the sensor through air. The interference source
can either be a part of the interfered system or be an electrically isolated unit. The
conducted interference is incurred when the interference source and the sensor are
connected via magnet wire or signal cable and the interfering signal is transmitted
from one unit to the other unit through the cable. Usually affecting the power supply of
device, the conducted interference can be controlled by the filter. The radiated
interference can have impact on any signal path of the device, and is difficult to
shield.
(1) Effective power grid interference control measures shall be taken against the
power supply system.
(2) The working earth of the wireless AP shall be kept far away from the earthing
installation and lightning earth of power equipment instead of sharing.
(3) The device shall be kept far away from high-power radio station, radar station and
high-frequency & heavy-current devices.
(4) Electrostatic shielding shall be applied.
2.8 Precautions for Optical
Fiber Connection
Before optical fiber connection, please make sure the optical connector matches with
the optical interface used. Meanwhile, please pay attention to the transmitting and
receiving directions of optical cable. The transmitting interface of this device shall be
connected to the receiving interface of counterpart device, while the receiving
interface of this device shall be connected to the transmitting interface of counterpart
device.
2.9 Installation Tools
Table 2-1 List of installation tools
Common tools
Cross screwdriver, straight screwdriver,
related cables and optical cables
Mounting bolts, diagonal pliers, strapping
tape
Special tools
Static-free tools
Instrument
Multimeter
RG-AP620-H is not accompanied with a tool kit. Tools must be
prepared by the user.
3 Product Installation
Make sure you have carefully read the contents of Chapter II.
Make sure the requirements described in Chapter II have been
satisfied.
3.1 Installation Flow
3.2 Verifications Before Installation
Verify the following points before the installation:
Whether the installation site satisfies the requirements on temperature and humidity;
Whether the installation site satisfies requirements on electric current and whether
the power supply is ready.
Whether the relevant network cables have been deployed at the installation site.
3.3 Install AP620-H Main Unit
First fix the mounting bracket to the rear of main unit and tighten the screws on the
mounting bracket, as shown below:
Figure: Fix the mounting bracket to the rear of AP620-H and tighten the screws on the
mounting bracket
Prepare to mount the main unit onto the hold pole (parallel or vertical), as shown
below:
Parallel installation
Vertical installation
There are two groups of mounting holes on the mounting bracket. Put the U-hoop in
respective holes according to the mode of installation and lock screws to mount
AP620-H onto the hold pole.
Mounting holes on the bracket
Parallel installation
Vertical installation
Tighten the screws to fix the hoop
3.4 Install Outdoor Antenna
The outdoor antenna can be divided into directional outdoor antenna and
all-directional outdoor antenna. The all-directional antenna can be directly installed
onto the main unit. Install the direction antenna through the following steps.
1. Make sure the directional antenna is protected by lightning arrester. If there is no
lightning arrester nearby, a lightning arrester shall be installed at the top of hold pole.
2. Install the pole at top of building by mounting to the wall or the concrete post. Make
sure the pole is vertical to the group.
3. Properly ground the hold pole by using 40m4mm flat steel to connect the pole to
the lightning protection ground mat, and make sure the joint between flat steel and
ground mat is rustless.
4. According to the installation guide for directional antenna, use the mounting
bracket to mount the directional outdoor antenna onto the hold pole, and then adjust
the angle, as shown below:
Install the directional outdoor antenna
2. Mount the all-directional outdoor antenna onto the hold pole.
Pay attention to the following precautions when installing the all-directional outdoor
antenna:
1. When installing the all-directional antenna, the lightning arrester must not be
directly welded onto the hold pole (there mustn't be any metallic object within 1m
horizontal reach of the all-directional antenna). Instead, a lightning arrester must be
separately erected between the hold poles of two all-directional antennae. The height
of lightning arrester must allow the top of all-directional antenna to be covered by the
protection angle.
2. After the installation, make sure the top of hold pole is flush with the lower anchor
ear of the antenna.
3. The height of antenna must meet the signal coverage requirements, and the top of
antenna must be covered by the 45-degree protection angle of the lightning arrester.
Install outdoor all-directional antenna
3. Directly install all-directional outdoor antenna on the main unit.
When small-gain mast-type all-directional antenna is used, the antenna can be
directly mounted onto the main unit through the following steps:
1. Attach the antenna feeder lightning arrester to the antenna feeder port of the
device.
2. Connect the mast-type antenna to the antenna feeder lightning arrestor via the
connector.
3. Ground the earth lead of antenna feeder lightning arrester.
4. Ground the earth wire of device.
3.5 External Cables
1. Thread the network cable without modular plug through PG9 waterproof plug.
2. After that, prepare the modular plug.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Ruijie RG-AP620 Series Installation guide

Category
Network switches
Type
Installation guide

Ruijie RG-AP620 Series is a wireless access point designed for demanding outdoor applications. It can serve as a Fit AP and network with wired/wireless integrated switch/wireless controller, or act as a FAT AP and provide wireless access service for WLAN users. The device has one 1 Gigabit combo port (1 10/100/1000M self-adaptive RJ45/SFP combo port), 1 console interface, and 6 antenna interfaces. It adopts POE input and complies with 802.3at protocol, with input voltage range of 36-57V and rated current of 0.57A.

Ask a question and I''ll find the answer in the document