Baxtran M80 User manual

Type
User manual

This manual is also suitable for

ENENUSER'S MANUAL T-TOUCH SERIES
V.5_25/11/2019
EN
COMMERCIAL SCALES
TOUCH SERIES
USER MANUAL
marca propiedad de | est une marque de | trade mark property of:
Pol. Empordà Internacional Calle F. Parcela 15-16
17469 VILAMALLA - (Girona) SPAIN
T. (34) 972 527 212 - F. (34) 972 527 211
El fabricante se reserva el derecho de modificar sin previo aviso las características de sus productos para introducir mejoras técnicas o cumplir con nuevas regulaciones oficiales./Le
constructeur se réserve le droit de modifier les caractéristiques de ses produits en vue d’y apporter des améliorations techniques ou de respecter de nouvelles réglamentations./The
manufacturer reserves the right to modify the specifications of its products in order to make technical improvements or comply with new regulations.
ENENUSER'S MANUAL T-TOUCH SERIES
2
3
ENENUSER'S MANUAL T-TOUCH SERIES
EN
1. QUICK GUIDE 6
1.1 REQUIREMENTS 6
1.2 INTERFACES 6
1.3 TYPE OF POWER SOURCE 7
1.4 PAPER ROLL CHANGE - S70 / M80 8
1.5 SWITCHING ON AND OFF 9
2. GENERAL INFORMATION 10
2.1 SALES SCREEN 10
2.2 REAR SCREEN 12
2.3 ON-SCREEN KEYBOARD 13
3. OPERATION 14
3.1 FUNCTIONS 14
3.2 SALES OPERATION MODE 15
3.3 MANUAL ENTRY PRICE / QUANTITY 16
3.4 AUTO-ACCUMULATION MODE 17
3.5 REMOVE ACCUMULATED PRODUCTS 18
3.6 COLLECTION OPERATION 20
3.7 SALES RETURN 22
3.8 EDIT PLU 22
4. MAIN MENU SETTINGS 24
4.1 LOG IN/LOG OUT 25
4.2 SALES 26
4.3 ID SETTING 26
4.4 SETTINGS 30
4.4.1 BASIC INFORMATION 31
4.4.2 SYSTEM 34
4.4.3 WEIGHT 37
4.4.4 OPERATION 37
4.4.5 CALIBRATION 41
4.4.6 COMUNICATION 41
4.4.7 PREVIOUS SCREEN 42
4.5 USER INTERFACE 49
4.6 DATA 57
4.7 REPORTS 61
4.8 PRICE TYPE 62
4.9 PRINT FORMAT 62
ENENUSER'S MANUAL T-TOUCH SERIES
4
WARNING!
1. Check the voltage before connecting the scale. Use only the correct voltage
assigned to avoid damage.
2. Avoid using the scale in hazardous environments.
3. Avoid suddenly or strongly impacting the scale.
4. Avoid submerging the scale in water and in highly humid environments.
5. Do not turn on the scale when it has just undergone large temperature changes
to avoid possible damage.
5
ENENUSER'S MANUAL T-TOUCH SERIES
INTRODUCTION
The touch screen scales S70 and M80 are specially designed for shops, supermarkets, etc. They use a Linux-based operating system with touch
screens.
Characteristics
• Resistive touch screen system.
• 8" (S70), 10'' (M80) TFT LCD screen.
• 7'' (S70), 10'' (M80) customer HD screen.
• The customer's screen is able to play images and videos.
• Selectable weighing units.
• Built-in real time clock.
• 1 GB RAM and 1 GB FLASH memory.
• Unlimited data storage capacity*.
• 99999 PLU storage capacity.
• Multiple, customizable print formats.
• Connectivity with PC keyboard, mouse, barcode scanner and cash box.
• RS232x2: The serial communication port can be connected to a PC,
mini printer, ticket printer, label printer, etc.
• Report management.
Note: * Data storage depends on the availability of free memory
ENENUSER'S MANUAL T-TOUCH SERIES
6
1. QUICK GUIDE
1.1 REQUIREMENTS
Check that the power supply has the correct voltage required before use. The mounting location must be a stable surface free of heat, water and
moisture.
1.2 INTERFACES
M80 Series:
RJ-11 USB2 RJ-45 RS-232: COM1 MINI USB
S70 Series:
RS-232 X 2 RJ-11 RJ-45 MINI USB
USBPort x 2
JACK ADAPTER
RS-232 COM2
7
ENENUSER'S MANUAL T-TOUCH SERIES
INTERFACE QUANTITY DESCRIPTION
RJ11 1 Cash draw
USB 2For mouse, keyboard, barcode scanner
RJ45 1 Ethernet
RS232 2For printers or other supported equipment
1.3 TYPE OF POWER SOURCE
M80 Series
SWITCHING ON
LOADING
CONNECTOR
S70 Series
SWITCHING ON
LOADING
CONNECTOR
ENENUSER'S MANUAL T-TOUCH SERIES
8
1.4 PAPER ROLL CHANGE - S70 / M80
Push button to open Lift to open the lid Replace the paper roll
Peel off the paper Close Pull out the paper
9
ENENUSER'S MANUAL T-TOUCH SERIES
1.5 SWITCHING ON AND OFF
SWITCHING ON
Press and hold down the Power key until you hear a "beep", then
the scale will start the power up process.
SWITCH
SHUTTING DOWN
Press the key on the main menu, and press "confirm" on
the pop-up screen to turn off the equipment
SWITCH OFF KEY
Note: If you press and hold the "On" switch for a long period, the scale will turn off.
1- It is necessary to enter the user name and password to access the scale’s operations.
To access the scale’s operations, select the user name on the list and enter the password.
Default user name: admin
Default password: admin
2- It is necessary to press the "access" key to display the sales screen where, by pressing the "Menu" key, we access the main menu,
from which we can move through the scale’s different sections.
ENENUSER'S MANUAL T-TOUCH SERIES
10
2. GENERAL INFORMATION
2.1 SALES SCREEN
DISPLAY/
INDICATOR
DESCRIPTION
1 Zero
Tare
Stable
Displays the current weighing status
A
2 Range Displays the weighing range
4 Operator Displays who the active operator is
5 Capacity Displays the capacity, the minimum weight, and the division.
6 Version Displays the software version
7 Power supply Displays that it is connected to the electricity
8 Date and time Displays the date and time
9Tare Displays the tare value
10 Weight Displays the weight
11
ENENUSER'S MANUAL T-TOUCH SERIES
11 Unit price Displays the unit price
12 Total Displays the amount
13 Product Shows the product
14 Sales list Shows sales or vendor summary according to model
15 Category Displays the categories
16 PLU Keys To select the product
17 Active vendor Displays the active vendor and the total number of sales they have made
18 Vendor To select the vendor
19 Clear key To delete the current selection or product entry, price, or quantity
20 Quantity key To enter the quantity, in products sold in units.
21 Price key To enter the unit price manually
22 Delete key Delete selected sales item or the entire list if we do not have
any selected
23 PLU key To enter the PLUS stored search screen
24 Tare Key Weigh with container / without container
25 Zero key To zero the scale
26 Menu key To access the main menu
27 Feed key To advance the role
28 Check Key Print ticket quickly (short press)
Access the menu for account editing, discounts and payment methods (long
press).
Note: PLU keys and function keys are defined / designed according to custom settings
of the interface mode. For details, refer to the "Selecting Operation Keys" section (p. 53)
ENENUSER'S MANUAL T-TOUCH SERIES
12
2.2 REAR SCREEN
DISPLAY/
INDICATOR
DESCRIPTION
1 Product To display the selected product
2ATare To display the tare value
3 Total weight To display the total weight of the product
4 Unit price To display the unit price
5 Total price To display the Total price
6
Advertising To display the desired advertising (See page 43)
13
ENENUSER'S MANUAL T-TOUCH SERIES
2.3 ON-SCREEN KEYBOARD
The on-screen keyboard will open automatically to edit or enter new data.
Back
Tab: Use this key to change the field to be filled in.
Press to switch to the keyboard for special symbols and numeric keys.
Key to close the keyboard
o Change to Upper-case letter / lower-case letter
Press to switch to the main keyboard.
ENENUSER'S MANUAL T-TOUCH SERIES
14
3. OPERATION
3.1 FUNCTIONS
3.1.1 Switching On
During power-up, the scale will first run the operating system displaying T-Touch followed by the BAXTRAN logo. After the scale sets the current
weight as a new zero reference, the sales menu is automatically started after entering the user name and password. (Default admin / admin).
3.1.2 Display range
The scale will display the weight from -Max (tare function) to Max (gross weight)
3.1.3 Zero adjustment
Zero adjustment is performed by pressing the , key. This is only possible when the load receptor is not moving and the variation is within
the range set by metrology.
3.1.4 Tare
The tare weight of any container can be obtained by pressing the button and from that moment the net weight of the heavy object is shown.
How tare weight works:
Put the weight on the platter.
Press the key. Weight zero is displayed and the tare weight is subtracted. Remove the weight from the platter. The tare weight is displayed.
Only one tare weight value can be set. It will be shown as a negative value. This tare value can be erased by pressing the tare key when there
is no load on the platter. The tare operation cannot take place if the platter is moving.
3.1.5 Pre-Tare
POS scales have a preset tare function, press and hold the key until a pre-tare window appears to enter the tare value, clicking on the "OK"
key allows you to activate the entered value.
3.1.6 PLU (Price Look Up)
The scales can store up to 99999 unit price values, which can be accessed via the direct PLU keys or the PLU search key on the sales screen
keyboard.
3.1.7 Quantity
It allows you to calculate the total price of sales per unit (weighing results are not taken into account).
3.1.8 Gravity
The scales have a gravity compensation function that allows verification to be performed at a location with a different gravity constant from that
of the place of use. (Parameter blocked by calibration button).
3.1.9 Print
The scales have a built-in printer and printing is done automatically when the user presses the Check key to finish the collection.
3.1.10 Software version
The software is separated into weighing software, application software, keyboard software, display software, print software, etc.
15
ENENUSER'S MANUAL T-TOUCH SERIES
3.2 SALES OPERATION MODE
M80 S70
a. Select a salesperson.
Press the button to choose the desired salesperson
Select a vendor from the list.
It
displays the active salesperson for the accumulation
ENENUSER'S MANUAL T-TOUCH SERIES
16
SEARCH PLU (PRODUCT LOOK UP)
Search for direct PLU:
Click on the PLU of the desired category. Use the group/category key to select different product groups or categories.
Search for indirect PLU: Click on the button to enter the product search:
a) Product search via PLU number
b) Product search via alphabetical order.
17
ENENUSER'S MANUAL T-TOUCH SERIES
3.3 MANUAL ENTRY PRICE / QUANTITY
When product information is not preset on the scale, click to manually enter the unit price and click .
Users can also enter the quantity manually to obtain the amount of the un-
weighed products. Click the key to manually enter the quantity. (This
function can also be used with PLU configured as parts)
3.4 MANUAL / AUTO ACCUMULATION
MANUAL ACCUMULATION:
Use this application to manually add weight values to the sales list.
- Select a PLU and place the items to be weighed on the platter.
- Once the stability indicator is displayed, press the vendor key to add the line to the sales list, the scale will beep and the sales list will
add a new item to the sale.
- Remove the element from the platter and continue the next operation.
ENENUSER'S MANUAL T-TOUCH SERIES
18
AUTOMATIC ACCUMULATION:
Use this application to automatically add weight and quantity values.
The "operation settings" allow you to select automatic accumulation on loading or unloading.
Note: Automatic accumulation must be active,
consult Settings> Operation settings> Auto-accumulation > On loading / On unloading.
Auto-accumulation on loading:
- Select a PLU and place the item to be weighed on the platter.
- Once the stability indicator is shown on the display, the scale will
beep and the accumulation will be added to the sales list.
- Remove the article from the platter and proceed with the next op-
eration.
Auto-accumulation on unloading:
- Select a PLU and place the item to be weighed on the platter.
- Remove the item from the scale platter, the scale will beep and a
new item will be added to the sales list.
- Continue the next operation.
3.5 REMOVE ACCUMULATED PRODUCTS
Accumulation list:
Select the products from the sales list to remove them.
19
ENENUSER'S MANUAL T-TOUCH SERIES
Select the key to delete the selected
items.
If you have the sales list in the main window (M80), you can press
the key to delete the previously selected line.
Note: items deleted from the sales list may be retrieved. Select the deleted item and click or , as the case may be.
Note: If the main window of the user interface of your version does not have a sales list, you must select and delete
the item in the billing window.
If you click on the key in the sales window without having selected any item from the sales list, the entire sales list of the active
vendor will be deleted. Also on the sales list in the incoming billing window but by pressing .
1) Sales list
2) Selected element
3) Deleted element
ENENUSER'S MANUAL T-TOUCH SERIES
20
4) Deleted element selected
5) Deleted element retrieved
3.6 COLLECTION OPERATION
1. Select a vendor to make the collection, 2. press
the key to print the ticket, or press and hold
the key to access the billing menu.
1.
2. 3.
4.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Baxtran M80 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI