Riva RE12K Installation guide

Type
Installation guide
www.rivatech.de
Specification subject to change without notice
RE12K
Installation Guide
03-2014-A www.rivatech.de 2
Precaution
Please read this manual carefully before installing the unit.
Place the product in a dry and ventilated environment.
Use a damp cloth for cleaning. Never use chemical agents or abrasives.
Use only the accessories and spare parts recommended by the product manufacturer.
03-2014-A www.rivatech.de 3
Table of Contents
Precaution ................................................................................................................ 2
1. FEATURES ............................................................................................................. 4
2. PACKAGE CONTENTS............................................................................................. 5
3. PART NAMES ........................................................................................................ 6
4. INSTALLATION ...................................................................................................... 8
Requirements for installation ................................................................................................... 8
Compatible Blades..................................................................................................................... 9
Mounting a video encoder blade ............................................................................................ 10
APPENDIX(A) : SUBRACK ......................................................................................... 11
Specifications .......................................................................................................................... 11
Power Consumption ................................................................................................................ 12
APPENDIX (B): DIMENSIONS ................................................................................... 13
REVISION HISTORY ................................................................................................. 14
RC/RE Series RE12K Installation Guide
03-2014-A www.rivatech.de 4
1. FEATURES
RE12K compresses video/audio data and transmits the compressed video/audio data through
the network in real time. RE12K provides a high quality video image with a limited bandwidth
and storage capacity. These products are ideally suited for a wide range of surveillance and
remote monitoring applications. Main features are highlighted below.
19” / 1U Aluminum Sub-Rack
Support up to 3units of 4CH RE Blade Card (total 12 channels @ D1)
Hot-swappable encoder blades
Identification of each sub-rack and each blade unit ( for easy and quick maintenance)
Temperature sensor included
Detect power supply unit operation (self-diagnosis)
Detect fan unit operation (self-diagnosis)
Applied device:
o RE4000A-R12 (It is the blade version of RE4000A)
o RE4000-R12 (RE12K version after manufacturing date Oct 1st, 2009)
o RE4000L-R12(RE12K version after manufacturing date Oct 1st, 2009)
o RE4100-R12 (RE12K version after manufacturing date Oct 1st, 2009)
RC/RE Series RE12K Installation Guide
03-2014-A www.rivatech.de 5
2. PACKAGE CONTENTS
Please unpack the package carefully, and handle the equipment with care.
The packaging contains:
Video Encoder Rack
(Cover platex3 pre-installed)
AC Power Cord x 1
(Only one type of power cord will be included
in the package)
The contents above are subject to change without prior notice.
Note
i
(UK)
(USA)
03-2014-A www.rivatech.de 6
3. PART NAMES
Figure 1. Front view of subrack
Fan Status LED
It indicates if a fan unit works properly.
Power Status LED
Green light will be turned on when the power is connected.
The color of LEDs is subject to change according to the firmware version
** System Status LEDs and reset buttons
Please refer to the installation guide for each blade model.
Figure 2. Rear view of subrack
LAN connector
10/100 Mbps networks and connection via the standard RJ-45 connector
USB port
Connection for USB flash drive for extra storage
*The USB port is not supported for RE4000L-R12 and RE4100-OV-R12.
Video Input connectors
Connectors for four channels of video input for each encoder blade
I/O terminal connector
It provides the physical interface for up to 18 I/Os including RS-485.
The pin assignment is described and explained with the image and the table below.
Pin assignments for the I/O connector of RE12K
Note
i
Vin1-1 Vin1-2 Vin1-3 Vin1-4
IO1
RACK ID
IO2
IO3RS-232
Vin2-1 Vin2-2
Vin2-3
Vin2-4
RS-232
Vin3-1 Vin3-2 Vin3-3 Vin3-4
RS-232
Ethernet 1
USB 1
Ethernet 2
USB 2
Ethernet 3
USB 3
Rx
Tx
RS-232
2 C 1 2 3
3 41 2
4
1
C
AoutDI
DO Ain
1
IO
RS-485
Reserved
2 3 41
RS-485
1 2 3 4
DI
[
NVE / NVC
]
[
NVN
]
IO
2-1
2-8
1-1
1-10
Vin1-1 Vin1-2 Vin1-3 Vin1-4
IO1
RACK ID
IO2
IO3RS-232
Vin2-1 Vin2-2
Vin2-3
Vin2-4
RS-232
Vin3-1 Vin3-2 Vin3-3 Vin3-4
RS-232
Ethernet 1
USB 1
Ethernet 2
USB 2
Ethernet 3
USB 3
Rx
Tx
RS-232
2 C 1 2 3
3 41 2
4
1
C
AoutDI
DO Ain
1
IO
RS-485
Reserved
2 3 41
RS-485
1 2 3 4
DI
[
NVE / NVC
]
[
NVN
]
IO
Vin1-1 Vin1-2 Vin1-3 Vin1-4
IO1
RACK ID
IO2
IO3RS-232
Vin2-1 Vin2-2
Vin2-3
Vin2-4
RS-232
Vin3-1 Vin3-2 Vin3-3 Vin3-4
RS-232
Ethernet 1
USB 1
Ethernet 2
USB 2
Ethernet 3
USB 3
Rx
Tx
RS-232
2 C 1 2 3
3 41 2
4
1
C
AoutDI
DO Ain
1
IO
RS-485
Reserved
2 3 41
RS-485
1 2 3 4
DI
[
NVE / NVC
]
[
NVN
]
IO
( RE4100-OV-R12 blade inserted)
RC/RE Series RE12K Installation Guide
03-2014-A www.rivatech.de 7
Pin
RE4000A-R12
RE4000-R12
RE4000L-R12
RE4100-OV-R12
1-1
Channel 1, Digital Input (Sensor)
Channel 1, RS-485 +
1-2
Channel 2, Digital Input (Sensor)
Channel 1, RS-485 -
1-3
Channel 3, Digital Input (Sensor)
Channel 2, RS-485 +
1-4
Channel 4, Digital Input (Sensor)
Channel 2, RS-485 -
1-5
Ground, Digital Input Channel 1-4
Ground,RS-485
Channel 1-2
1-6
Channel 1, RS-485 +
Channel 3, RS-485 +
1-7
Channel 1, RS-485 -
Channel 3, RS-485 -
1-8
Analogue Video Output
Channel 4, RS-485 +
1-9
Audio Output
Channel 4, RS-485 -
1-10
Ground, Audio Output
Ground,RS-485
Channel 3-4
2-1
Channel 1, Digital Output (Alarm)
Channel 1,
Digital Input (Alarm)
2-2
Channel 2, Digital Output (Alarm)
Channel 2,
Digital Input (Alarm)
2-3
Ground, Digital Output Channel 1-2
Channel 3,
Digital Input (Alarm)
2-4
Channel 1, Audio Input
Channel 4,
Digital Input (Alarm)
2-5
Channel 2, Audio Input
Ground
2-6
Channel 3, Audio Input
Ground
2-7
Channel 4, Audio Input
Ground
2-8
Ground, Audio Input Channel 1-4
Ground
RE4100-OV-R12 has pins for Audio Input / Output and Digital Output assigned
on the front panel of the encoder blade. Please refer to the installation guide
for the detail.
Dip Switch for rack ID
It sets a rack ID to distinguish a rack from multiple racks. When all DIP switches are turned off,
the RACK ID is 0, and when all switches are turned on, the RACK ID is 15.
When you use an H.264 blade, make sure to reboot the blade after changing
its rack ID. Otherwise, the change will not be applied.
Switches for power supply
Individual switch for the Power Supply.
Power connector
Connector for the main power cord included in the package.
Note
i
Note
i
RC/RE Series RE12K Installation Guide
03-2014-A www.rivatech.de 8
4. INSTALLATION
Requirements for installation
General placement requirements
- Ambient temperature: 0 ~ 60 (32 ~ 140 )
- Relative humidity: Up to 85% RH
- There must be a minimum of 5 cm free space on the top, bottom, front and rear of RE12K to
ensure adequate ventilation.
- No excessive dust
Placement requirements for installation in a 19 equipment rack
- Never stack other units directly on top when mounting RE12K in an equipment rack; the
mounting brackets are not designed to support more than 1 unit.
- RE12K must be grounded to the same ground as the equipment rack.
- The equipment rack must be braced and bolted to the floor.
Requirements for power connection
- The correct AC power for your country is used.
- RE12K is intended for indoor use only.
- To prevent the risk of electrical shock when in contact with the unit casing, only
earthed/grounded power cords should be used to power RE12K.
- Protection against over-currents, short circuits and earth faults should be provided in the
building installation.
- If a foreign object is accidently dropped into the video encoder rack, always disconnect
power before attempting to remove the object.
Requirements before inserting encoder blades
- Input termination should be disabled by setting the corresponding hardware switch off to
connect a video encoder in parallel with other equipment. Failure to do so may affect the
image quality negatively. Please refer to each blade models installation guide for the detail.
- Front cover plates should be used on all empty slots.
- Please refer to the installation guide of each encoder blade for detailed hardware
information.
03-2014-A www.rivatech.de 9
Compatible Blades
RE4100-OV-R124100 R12
RE4000 R12
RE4000L R12
RE4000A R12
4CH H.264 ENCODER
STATUS
DATA
OFF
PAL NTSC
03-2014-A www.rivatech.de 10
Mounting a video encoder blade
Follow these steps to mount a video encoder blade in RE12K.
1. If there is a front cover plate, remove it from the slot where the video encoder will be
mounted. This is done by unfastening the screws on both sides of the cover plate.
2. Slide the video encoder blade into the rack chassis. Make sure that a reset button is at
the bottom of the blade when it is inserted into RE12K.
3. Make sure to securely insert the blade into the slot, and fix it by fastening the screw
clockwise on both sides of the blade.
RC/RE Series RE12K Installation Guide
03-2014-A www.rivatech.de 11
APPENDIX(A) : SUBRACK
Specifications
Parameter
Value
Construction
Aluminum, 19 / 1U Sub-Rack
Applied Device
RE4000A-R12
RE4000-R12
RE4000L-R12
RE4100-OV-R12
Available Slots
3 ea (Hot Swappable Blades)
Power
Input
85 ~ 264 VAC, 47~63Hz, 2A
Type
Single Power Supply
Connector
(Each slot)
Video Input
4 ch (BNC Type)
Audio Input / Output
4 ch / 1 ch
(2.5 mm Pitch
Terminal Block,
Pluggable)
2 ch / 1 ch
4 ch / 1 ch
Digital Input / Output
4 ch / 2 ch
(2.5 mm Pitch
Terminal Block,
Pluggable)
2 ch / 2 ch
4 ch / 4 ch
RS-485
Supported
4 ch
Network
10/100 Base-T
USB
RE4000A-R12
: supported
RE4000-R12
: supported
(1
st
module only)
-
-
Fan Unit
6,500 rpm x 2ea
Temperature
0 ~ 60 (32 ~ 140 )
Humidity
Up to 85% RH
Dimension
482(W) x 44(H) x 286(D) mm
Weight
1.8kg (except blades and Power Cable included)
* RE4000-R12 Audio Output: 1 channel of Audio Output for 1
st
module only
Digital Input: 2 channels of Digital Input respectively for 1
st
module and 2
nd
Digital Output: 1 channel of Digital Output respectively for 1
st
module and
2
nd
module
RE4100-OV-R12 Audio Output: Audio mixed out as 1 channel
03-2014-A www.rivatech.de 12
Power Consumption
Rack case with 3 x RE4000-R12
Input Voltage
12 V
Current
2720 mA
Consumption
32.64 W
Rack case with 3 x RE4000L-R12
Input Voltage
12 V
Current
2000 mA
Consumption
24 W
Rack case with 3 x RE4100-OV-R12
Input Voltage
12 V
Current
2210 mA
Consumption
26.52 W
03-2014-A www.rivatech.de 13
APPENDIX (B): DIMENSIONS
(Unit: mm)
Vin1-1 Vin1-2 Vin1-3 Vin1-4
IO1
RACK ID
IO2
IO3RS-232
Vin2-1 Vin2-2
Vin2-3
Vin2-4
RS-232
Vin3-1 Vin3-2 Vin3-3 Vin3-4
RS-232
Ethernet 1
USB 1
Ethernet 2
USB 2
Ethernet 3
USB 3
Rx
Tx
RS-232
2 C 1 2 3
3 41 2
4
1
C
AoutDI
DO Ain
1
IO
RS-485
Reserved
2 3 41
RS-485
1 2 3 4
DI
[
NVE / NVC
]
[
NVN
]
IO
RC/RE Series RE12K Installation Guide
03-2014-A www.rivatech.de 14
REVISION HISTORY
MAN#
DATE(M/D/Y)
Comments
01A.00
08/24/2009
Created.
01A.01
11/04/2010
Explained about the dip witch for Rack ID and termination
03-2014-A
03/31/2014
Overall update
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Riva RE12K Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI