ALLEGION RC-04 ISONAS Reader Controll User guide

  • I've reviewed the wiring diagram for the ISONAS RC-04 access control system, which includes the EEB2 exit button. This document provides detailed instructions on how to wire these components, including the power supply, magnetic lock, and fire alarm relay. I'm ready to answer specific questions you may have about the installation process.
  • What type of cable is used for connection to the PoE Switch?
    What should be done with unused wires?
    What is the purpose of the in-rush suppressor?
    What jumper wire should be removed?
Black
Orange
Yellow
Red
White
Blue
Green
Brown
Cat5e/6 to PoE Switch
4750 Walnut Street Suite 110
Boulder, CO 80301
www.isonas.com
Date:
2-13-18
Drawn By:
David Tamarchenko
Version:
1.00.01
Dwg No: Sheet
1
of
1
RC.04.POE.PowSup.MAG.REXButton.
DSM.ReadInReadOut
Isolate and insulate
wires not used
NC Door
Contact
WHT
YLW
BLK
ORG
NO
NC
COM
GND
V+
WHT
YLW
BLK
ORG
NO
NC
COM
GND
V+
Remove factory jumper wire
from V+ to COM!
Black
Orange
Yellow
Red
White
Blue
Green
Brown
Isolate and insulate
wires not used
Cat5e/6 to PoE Switch
RC-04 on Exterior
or Unsecure Side:
Disable unlock on
Rex/Aux in Pure
Access for
increased security
RC-04 on Interior
or secure Side:
Disable unlock on
Rex/Aux in Pure
Access for
increased security
WHT
YLW
BLK
ORG
NO
NC
COM
GND
V+
WHT
YLW
BLK
ORG
NO
NC
COM
GND
V+
Remove factory jumper wire
from V+ to COM!
WHT
YLW
BLK
ORG
NO
NC
COM
GND
V+
Remove factory jumper wire
from V+ to COM!
In Rush Suppressor
installed close to lock
12/24 VDC
Magnetic Lock
IRSIRS
Com
NC
NO
Fire
Alarm
Relay Com
NC
NO
Fire
Alarm
Relay
Exit Button
such as
Securitron
EEB2
COM
NC
+12VDC
-12VDC
COM
NC
+12VDC
-12VDC
COM
NC
+12VDC
-12VDC
+12VDC
-12VDC
+12VDC
-12VDC
+12VDC
-12VDC
12/24VDC
Power Supply
WARNING:
You must check with your local AHJ
If this is going to control an
emergency egress door. Delayed
egress hardware may be required in