Platinum 4000 H Installation and User Manual

Category
Power adapters & inverters
Type
Installation and User Manual

This manual is also suitable for

Installation and user guide
Inverter
2100 H, 3000 H, 4000 H, 4600 H
As at 09/2012, Material no. 753 840-AB
EN
2
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
3
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Contents
1 Introduction 5
1.1 PLATINUM H 5
1.2 About this manual 5
1.3 Symbols used 5
1.4 Symbols on product and packaging 6
2 Safety 7
2.1 Intended usage 7
2.2 Improper usage 7
2.3 Personnel requirements 7
2.4 General safety instructions 7
3 Installation 8
3.1 Scope of delivery 8
3.2 Unpacking 8
3.3 Assembly 9
3.4 Connection 12
4 Placing into operation 23
4.1 Switching on 23
4.2 Navigation in the Installation Menu 23
4.3 Installation Menu 25
4.4 Commissioning after replacement of a device 32
5 Operation of the inverter 33
5.1 Control elements and displays 33
5.2 Operation display 34
5.3 Isolation from the generator field 37
Contents
4
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
6 Menu on the inverter 38
6.1 Menu operation 38
6.2 Menu tree 39
6.3 Status menu 40
6.4 Setup menu 43
6.5 Commands menu 51
6.6 Alarm Setup menu 53
6.7 Event Log menu 56
6.8 Statistics menu 57
7 Web server 58
7.1 Connection between inverter and computer 58
7.2 Starting the web server 61
7.3 Menu tree 62
7.4 Home 63
7.5 Statistics 66
7.6 Setup 67
7.7 Event Log 75
7.8 Status 76
7.9 Help 78
7.10 Logout 78
8 Maintenance and cleaning 79
8.1 Maintenance 79
8.2 Cleaning 79
9 Faults and troubleshooting 80
9.1 Checklist in the event of faults 80
9.2 Event list 80
9.3 Faults and troubleshooting 85
10 Technical data 86
11 Taking out of operation 88
12 Disposal 89
Contents
5
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Introduction
1 Introduction
1.1 PLATINUM H
Inverters in the PLATINUM H series are single-phase feed-in inverters for different
power ranges; see “Technical data” on page 86.
Inverters in the PLATINUM H series are equipped with an integrated web server, which
allows data to be viewed and evaluated via a network or via the internet.
Up to 30 PLATINUM H inverters can be connected to form a single inverter system via
the CAN network.
1.2 About this manual
This installation and operating manual describes the installation and operation of the
PLATINUM inverters of the types 2100 H, 3000 H, 4000 H, 4600 H.
Additional documents
The following additional documents are available in the download area of our website
www.platinum-nes.com:
Detailed installation and user guide
Information on fault current protection devices
Detailed list of events for detecting/eliminating faults
Overview of country and grid codes
Declaration of conformity and certificates
Manufacturers warranty
1.3 Symbols used
1.3.1 Notes
Notes give tips on how to work easily and safely or contain further
information.
1.3.2 Structure of warnings
WARNING WORD
Type, source and consequence of the hazard!
f Measures to avoid the hazard.
6
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Introduction
1.3.3 Hazard levels in warnings
Symbol Warning
word
Probability of occurrence Consequences of
non-observance
DANGER
Imminent danger Death, serious injury
WARNING
Potential danger
Death, serious injury
CAUTION Potential danger Minor injury
CAUTION Potential danger Damage to property
1.4 Symbols on product and packaging
The following symbols are used on the type plate on the bottom right-hand side of the
inverter:
Symbol Meaning
High voltage
Risk of electric shock
Discharge time: 60 minutes
High voltages may still be present in the interior of the
inverter up to 1 hour after it is switched off.
Hot surface
The cooling element on the rear of the inverter can get very
hot and reach temperatures of up to 90°C.
Read the manual
Read this manual before carrying out any work on the in-
verter.
Disposal
Do not dispose of PLATINUM inverters in household
waste.
Packaging and replaced parts are to be disposed of in
accordance with the regulations of the country in which the
inverter was installed.
7
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Safety
2 Safety
2.1 Intended usage
Inverters are to be used solely for the purpose of feeding photovoltaically generated
solar energy into the public grid.
All other usage does not comply with the regulations.
2.2 Improper usage
The inverters are not to be used in island grids.
The inverters are not to be used in vehicles.
The inverters are not to be used in areas at risk of explosion (flour dust, sawdust,
etc.).
The inverters are not to be exposed to direct sunlight.
The inverters are not to be used in areas in which the ammonia content of the air
exceeds 20 ppm.
All warranty claims will be rendered null and void in the event of failure to comply
with the warranty terms or the information provided in this operating and installation
manual.
2.3 Personnel requirements
The inverter may only be installed and put into operation in accordance with this
installation and user guide by trained specialist personnel, for example:
Service partners who are authorised by PLATINUM
Authorised specialist personnel with knowledge of the applicable guidelines and
standards
2.4 General safety instructions
The inverters are to be used in their original state without independent modifications
and in a technically perfect condition.
Steps must be taken to ensure that the following are adhered to when assembling
and connecting the inverter and the PV system:
Guidelines and regulations valid in the respective country
Provisions of the trade associations, TÜV, VDE (Association for Electrical, Electronic
& Information Technologies)
Technical connection conditions of the energy supplier responsible
National and international regulations and provisions
Ensure that all protection devices are working correctly.
Observe the operating conditions - refer to “Technical data” on page 86.
8
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Installation
3 Installation
3.1 Scope of delivery
Inverter
Wall bracket
Brief guide
Installation materials
Grounding kit
3.2 Unpacking
CAUTION
Risk of injury!
f Wear safety shoes when unpacking the inverter and during
installation.
f Ensure that the inverter is positioned securely.
1
1. Place the box the correct way up on
the floor (note the lettering).
2. Cut through the seal and open the box
on the top side.
3. Take out the wall bracket from the
packaging.
4. Take off the upper padding elements.
5. Raise the inverter by its underside and
lift it by the handles (1) out of the box.
6. Remove the lower padding element.
7. Take out the installation materials and
the grounding kit.
8. Take out the brief guide.
Enclosed installation materials
Seals for the AC connection
Jumpers for grounding and network termination
Fastening and locking clamp for anti-theft protection
9
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Installation
3.3 Assembly
3.3.1 Safety instructions
WARNING
Injury may result if the inverter falls!
f Use fixing materials suited to the assembly wall and the weight of the
inverter.
f Wear safety shoes during assembly and disassembly.
f Ensure that the inverter is positioned securely.
CAUTION
Damage to the inverter due to excessive buildup of dust.
f Avoid excessive build-up of dust.
f Avoid build-up of dust with electrically conductive dust particles.
In order to comply with the requirements of standard IEC-62109, a
possibility must be provided for tool-free isolation of the solar generator.
If the design does not feature an integrated DC isolator, an external
isolation device is mandatory; this must be easily accessible.
PLATINUM recommends that the inverter should not be installed in living
quarters.
10
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Installation
3.3.2 Mounting the inverter
2
4
150 150
400300
Dimensions in mm
1. Choose a suitable location for mount-
ing. When doing so, note the follow-
ing:
Mount the inverter in a suspended,
vibration-free position.
The wall chosen for mounting must
be suitable for the weight and
temperature (90°C).
Make sure the correct dimensions
and distances are maintained.
The display should be at eye level
(approx. 1.60 m off the floor).
The inverter must be easily ac-
cessible without additional tools or
equipment.
2. Fix the wall bracket to the assembly
wall with suitable fixing materials.
2 3
54
3. Lift the inverter and insert the upper
mountings (2) in the upper slots (3) on
the wall bracket.
4. Align the lower mountings (4) on the
lower slots (5).
11
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Installation
5. Slide the inverter onto the bracket.
Anti-theft protection
6
Two clamps are included in the scope of
delivery, with the aid of which the inverter
can be protected against theft.
A padlock is not included in the scope of
delivery.
1. Mount the fastening clamp (6) with
two screws on the underside of the
inverter.
7
2. Guide the locking clamp (7) through
the fastening clamp.
3. Insert the padlock through the eyelet
on the locking clamp and lock.
12
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Installation
3.4 Connection
3.4.1 Preparatory work
1. If present, disconnect the DC voltage
side with the external disconnect
device from the solar generator.
2. If present, move the switch knob of
the DC isolator on the underside of
the device to the 0 position.
8
Take off the lower cover
t Remove the four screws (8) from the
lower cover and take off the cover.
For safety reasons, it is ESSENTIAL that the following sequence is AL-
WAYS followed when the connections are established:
1. Connect the network.
2. Connect the AC voltage.
3. Configure the grounding of the PV modules.
4. Mount the lower cover.
5. Connect the DC voltage.
13
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Installation
3.4.2 Network connection
The inverter is equipped with two different network connections:
CAN
Ethernet
CAN: for communication between
multiple inverters
Ethernet: for communication between
the integrated web server of the
master and a computer or the internet
Up to 30 PLATINUM H inverters can be connected into a network with
an overall length of up to 100 m.
Network cable
CAN: cross-section 0.21 mm
2
, max. 100 m
Ethernet: CAT 5 shielded twisted-pair cable with pre-assembled RJ45 plugs
Connect
+POS
10
1. Unscrew the network screw
connection (10) from the left-hand
underside of the inverter.
2. Take out the three-way screwed cable
connection insert.
14
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Installation
11
3. If required, cut open the cable insert
(11) to a width of around 1 mm for the
Ethernet cable.
12
4. Insert the Ethernet cable (12) in the
cable insert.
13
5. Route the CAN cable (13) through the
bore(s) in the cable grommet.
6. Feed all network cables into the hous-
ing from below.
15
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Installation
7. Tighten the network screw connec-
tions.
14
CAN
H
L
COMGND
H
L
COMGND
15
8. Connect the CAN cable to the
terminal block (14). When doing this,
make sure that the lines L and H are
not accidentally swapped over during
connection.
Incoming line: left-hand terminals L
and H
Outgoing line: right-hand terminals
L and H
9. At the master inverter, connect the
plug of the Ethernet cable with the lug
facing towards the rear into the socket
(15).
Termination
Termination via an internal terminating resistor ensures correct operation of the
network. This is done by means of a jumper, which lies across the CAN terminal block
and short-circuits two pins.
No jumper is fitted at the factory, so the terminating resistance is not activated.
The terminating jumper is included with the supplied installation materials.
Inverters in the network Jumper position Meaning
Individual (standalone)
inverter
Jumper inserted Terminating resistance activated
First/last inverter in the
network
Jumper inserted Terminating resistance activated
All other inverters in the
network
No jumper
Terminating resistance de-
activated
16
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Installation
16
1. At each inverter, check that the jumper
(16) is in the correct position (in ac-
cordance with the table above).
2. If not, correct the jumper position
accordingly.
3.4.3 Connect the AC voltage
DANGER
Risk of death due to high AC voltage!
f Switch off the mains voltage supply (AC side) before connecting the
inverter (safety device).
f Make sure that the central isolation device can be accessed freely.
f Only connect the inverter to TN or TT networks (see IEC 60364-1)
with 230 V.
f Observe max. fuse protection permitted on the AC voltage side; see
“Technical data” on page 86.
f Establish the AC voltage connection with a circuit breaker.
PLATINUM recommends a type C miniature circuit breaker.
f If an external residual current protective device is required, PLATINUM
recommends using a residual current protective device (RCD) of
type A.
CAUTION
Destruction of the inverter!
f Never connect inverters between two phases.
f Never mix up the phases with PE or N.
f If several inverters are connected, distribute them across the three phases so
that the differences in feed-in power between the phases do not exceed the
maximum permitted unbalanced load of the grid operator.
17
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Installation
Prepare the connection cable for the AC voltage
Dimensioning the wire cross-section is the responsibility of the
electrician and depends on the cable length and installation situation.
Min. cross-section 6 mm
2
Max. cross-section 16 mm
2
1. Protect the AC voltage connection lines with appropriate fuses; see “Technical data”
on page 86.
2. Strip 18 mm of insulation from the AC voltage connection lines and add wire-end
sleeves.
Connect
The AC connection screw fitting does not have a seal. One of the sup-
plied seals must be used to ensure that the requirements for safety class
IP65 are met.
9
1. Unscrew the AC screw connection (9)
from the right-hand underside of the
inverter.
2. Route the prepared AC voltage
connection line through the AC screw
connection. Use a seal if required.
3. Feed the AC voltage connection line
into the housing from below.
4. Tighten the AC screw connection.
18
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Installation
5. Connect the AC voltage connection
cable to the inverter:
Terminal Assignment
GND Protective ground conductor
N Neutral conductor
L Feed-in phase
6. Tighten the terminals with a tightening
torque of 1.5 Nm.
3.4.4 Configuration of the grounding of the PV modules
The inverter meets all requirements in terms of technical safety.
Depending on the grounding of the connected PV modules, the following work may
need to be carried out on the inverter:
Grounding of the
PV modules
Inverter setup
Not grounded Factory setup
No further grounding measures required
Negative grounding Install grounding strap
Connect grounding jumper
Positive grounding Install grounding strap
Connect grounding jumper
Swap internal cables
Install grounding strap
WARNING
Risk of electric shock and damage to the inverter.
f Only install the grounding strap on grounded PV modules.
The grounding strap is included in the enclosed grounding kit.
19
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Installation
2 -NEG
GND/PE
Ungrounded
Terminal
Grounded
Terminal
12
17
N5
t Connect the grounding strap between
the DC grounding terminal (17) and
N5.
Connect grounding jumper
WARNING
Risk of electric shock and damage to the inverter.
f Only install the grounding jumper on grounded PV modules.
The grounding jumper is included in the enclosed grounding kit.
2 -NEG
GND/PE
Ungrounded
Terminal
Grounded
Terminal
12
18
t Plug in the grounding jumper at the
connector (18) (according to the
grounding of the PV modules):
Not grounded No jumper
Positive grounding Pin 1 and pin 2
Negative grounding Pin 2 and pin 3
20
Installation and user guide for PLATINUM inverters 2100 H, 3000 H, 4000 H, 4600 H
Installation
Swap over the internal cables if the PV modules are positively grounded
WARNING
Risk of electric shock and damage to the inverter.
f Only swap over the internal cables if the PV modules are positively
grounded.
At the factory, black cables are assigned to the connections N1 to N4 and red cables to
the connections P1 to P4. In the case of negatively earthed PV modules, this assign-
ment needs to be swapped over.
N4
N3
N2
N1
P4
P3
P2
P1
Ungrounded
Terminal
Grounded
Terminal
12
t Swap over the cables at the following
connections (swap red and black):
N1 and P1
N2 and P2
N3 and P3
N4 and P4
This concludes the work inside the inverter. The lower cover can be closed again.
8
t Attach the lower cover with the four
screws (8).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90

Platinum 4000 H Installation and User Manual

Category
Power adapters & inverters
Type
Installation and User Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI