  • Hello! I've analyzed the provided document about the Hobart CL 44eN and CLPS 66eN dishmachine installation, focusing on corner setup. It includes crucial details like minimum space needs, table connections, and features such as the table limit switch. I'm ready to address any specific questions you might have about this installation guide.
  • What is the minimum space required for corner applications?
    What is the recommended minimum length for a clean table?
    What does a table limit switch do?
CLeN Installation Guidelines – Corner Installation
D STANDARD TABLE HEIGHT 34" AFF (per spec sheets)
E ROOM CONSIDERATIONS
Delivery Path (Doorways/Elevators) should have a minimum clearance
of 307
8" W x 6812" H
F DISH MACHINE TABLE TO TABLE CONNECTION DIMENSIONS
For CL44eN, inside tank dimension is 44"
For CLPS66eN, inside tank dimension is 66"
See back
for detail
F
A
D
E
C
B
A FOR CORNER APPLICATIONS, A MINIMUM OF 23" OR 30" is required
to accommodate a side loader (SL23 or SL30). SL30 must be ordered if washing
sheet pans. Short vent hood is required for load end when using a side loader.
B HOBART RECOMMENDS MINIMUM 60" for clean table
(not including rolled rim/end splash) to accommodate three racks.
C TABLE LIMIT SWITCH pauses operation when clean dish table is full,
prolonging the life of the conveyor drive mechanism.
Let’s Talk
We’re ready to help you optimize your dishroom operations.
Call 888-378-1338 and talk to one of our experts today.
F48800 (04-23) ©2023 Hobart
Dishmachine Table Connections
Hobart
701 S. Ridge Ave. Troy, Ohio 45373
www.hobartcorp.com
SCAN TO FIND OUT MORE
www.hobartcorp.com/clen
SUGGESTED TRACK AND TABLE LAYOUT
SECTIONAL VIEW SHOWING
TABLE CONNECTIONS VIEW SHOWING HOLE LOCATIONS IN
TURNED DOWN PORTION OF TABLE
WIDTH OF
TRACKS
24-7/8"
CHAMBER
WIDTH
20"
11"
26-1/2"
AVG INSIDE
TABLE WIDTH
12-5/16"
C
L
MACHINE2 HOLES FOR BOLT
ING
TABLE TO TANK
FRONT OF
MACHINE
C
L
3/8"
3/8"
3"
1-1/4"
10-1/2" AVG
22"
INSIDE TANK
3"
USE SILICONE SEALER
BETWEEN TABLE AND LIP OF
TANK TO PREVENT LEAKAGE
1-1/4"
7/8"
TR
ACK HEIGHT
ABO
VE TANK LIP
1/4" - 5/16"
3"
1"
10"
3"
3/8"
1/2" 28"
INSIDE
2-7/8"
1-1/4"
45°
14 GA. STL ST
TWO HOLES FOR
BOLTING TABLES
TOGETHER
1/2"
SIDE LOADER
TANK
CUSTOMER’S
TABLE
7/8"
1" ROLL
3"
1"
10"
3"
3/8"
1/2" 21"
INSIDE
2-7/8"
1-1/4"
45°
14 GA. STL ST
TWO HOLES FOR
BOLTING TABLES
TOGETHER
VIEW LOOKING TOWARD SIDE LOADER TANK THROUGH CUSTOMER’S TABLE
SL30
SECTIONAL VIEW SHOWING
TABLE CONNECTIONS
SL23
CLEAN DISH TABLE CONNECTION DETAIL
SIDE LOADER TABLE CONNECTION DETAIL