  • I've reviewed the provided Installation Guidelines for the Hobart CL series dishwashers, specifically models CL 44eN and CLPS 66eN. This document details the necessary requirements for a straight installation, including table dimensions, clearances, and connection instructions. I am ready to address any questions you have about this document or the installation process.
  • What is the recommended minimum length for the clean table?
    What does the table limit switch do?
    What is the standard table height?
    What is the minimum clearance for the delivery path?
CLeN Installation GuidelinesStraight Installation
D ROOM CONSIDERATIONS
Delivery Path (Doorways/Elevators) should have a minimum clearance
of 307
8" W x 6812" H
E DISH MACHINE TABLE TO TABLE CONNECTION DIMENSIONS
For CL44eN, inside tank dimension is 44"
For CLPS66eN, inside tank dimension is 66"
See back for detail
A
B
C
E
D
A HOBART RECOMMENDS MINIMUM 60" for clean table
(not including rolled rim/end splash) to accommodate three racks.
B TABLE LIMIT SWITCH pauses operation when clean dish table is full,
prolonging the life of the conveyor drive mechanism.
C STANDARD TABLE HEIGHT 34" AFF (per spec sheets)
Let’s Talk
We’re ready to help you optimize your dishroom operations.
Call 888-378-1338 and talk to one of our experts today.
F48801 (04-23) ©2023 Hobart
Hobart
701 S. Ridge Ave. Troy, Ohio 45373
www.hobartcorp.com
Dishmachine Table Connections
SCAN TO FIND OUT MORE
www.hobartcorp.com/clen
SUGGESTED TRACK AND TABLE LAYOUT
SECTIONAL VIEW SHOWING
TABLE CONNECTIONS
VIEW SHOWING HOLE LOCATIONS IN
TURNED DOWN PORTION OF TABLE
WIDTH OF
TRACKS
24-7/8"
CHAMBER
WIDTH
20"
11"
26-1/2"
AVG INSIDE
TABLE WIDTH
12-5/16"
C
L
MACHINE 2 HOLES FOR BOLTING
TABLE TO TANK
FRONT OF
MACHINE
C
L
3/8"
3/8"
3"
1-1/4"
10-1/2" AVG
22"
INSIDE TANK
3" USE SILICONE SEALER
BETWEEN TABLE AND LIP OF
TANK TO PREVENT LEAKAGE
1-1/4"
7/8"
TRACK HEIGHT
ABOVE TANK LIP
1/4" - 5/16"
/