Legrand LightSense™ Fan Control, PSHCF Installation guide

Type
Installation guide
PSHCF
LightSense
Fan Control
Installation Instructions
Specifications
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120VAC, 60Hz
Operating Temperature . . . . . . . . .32°F to 104°F (0°C to 40°C)
Maximum Load Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5A
Load Type Compatibility . . . . . . . . .Up to two ceiling fan motors
U.S. Patent 6,175,220. Other utility,
design, and foreign patents pending.
Syracuse, NY 13221-4822
800.223.4185
www.passandseymour.com
UNIT DESCRIPTION
The LightSense PSHCF fan control conveniently offers silent, four-speed
control of one or two ceiling fans, with a combined current rating up to 1.5 amps.
Call 800.223.4185 for Technical Support
CAUTION
THIS UNIT IS EXCLUSIVELY DESIGNED FOR
USE WITH CEILING FANS.
Do not use to control lighting, receptacles or
transformer-operated devices.
Do not use for a fan and a light wired together
on the same load wire.
This device should not be wired in the same
circuit as a GFCI circuit breaker or receptacle.
Visit our website for FAQs: www.passandseymour.com
INSTALLATION
For ease of installation, Pass & Seymour/Legrand recommends use of a deep
wall box.
1. Disconnect power to circuit by turning circuit breaker OFF before installation.
2. Remove existing wall plate and switch.
3. Strip existing wires
1
/
2
"
.
4. Connect the supply and load ground wires to the GND terminal on the back
of the unit.
5. Connect the white (Neutral) fan control wire to the white supply and load
wires, using a wire nut.
6. Connect the black fan control wire to the black supply Line, using a wire nut.
7. Connect the red fan control wire to the black load wire, using a wire nut.
8. Attach the wall plate.
9. Switch the circuit breaker back ON.
CAUTION
TURN THE POWER OFF AT THE CIRCUIT BREAKER BEFORE
INSTALLING THE DIMMER.
Call 800.223.4185 for Technical Support
LOAD
LINE
GND
Supply
Wires
Load
Wires
NEUT
Wire Legend
Load (red)
Ground
Line (blk)
Neutral (wht)
Wiring
INSTALL IN COMPLIANCE WITH ALL
APPLICABLE CODES & STANDARDS.
Failure to follow these instructions may cause
personal injury or equipment damage.
Visit our website for FAQs: www.passandseymour.com
OPERATION
Before use, set the fan to run in the appropriate direction and at full speed:
1. Press the top speed button on the LightSense™ fan control, and wait to
allow the fan motor to run up to full speed.
2. Using the controls on the fan (typically pull-chains), adjust so that the fan is
running at full speed, and in the desired direction.
The pull chains may now be removed or shortened.
Button and Paddle Functions
The fan control has a rocker paddle and five speed
control buttons. Use the speed buttons to select an
appropriate fan speed or OFF
Rocker paddle functions are described below.
The fan control may feel warm to the touch during normal operation.
Fan Maintenance
When fan maintenance is required, use the Air Gap Isolation feature for safety.
To activate the feature:
Press FIRMLY, so that the paddle clicks and latches in. Make sure the
status LED is extinguished, indicating that the load is isolated.
To release and return to normal operation, press .
When you see
touch the
top of the
paddle as
directed.
When you see
touch the
bottom of the
paddle as
directed.
Tap once Turn fan ON and resume last used speed
Tap twice Full speed
Press and hold Increase the speed
Tap once Turn fan OFF
Press and hold Decrease the level
Power Fail Memory
After a power failure, all LightSense™ devices automatically return to the state
they were in immediately prior to loss of power.
CLEANING
Clean using a cloth dampened only with water and a little mild detergent. Use of
solvents or hydrocarbon-based cleaners may cause permanent damage.
TROUBLESHOOTING
Fan control does not work and the status LED is flashing red
at 2Hz (10 times in 5 seconds):
The fan control has detected an overload condition and has shut down. To
clear the fault condition, press the OFF button and wait for the LED to turn
green. Remove power from the circuit and disconnect fans in excess of
rated load. Restore power and try again.
at 3Hz (15 times in 5 seconds):
The fan control detected a short-circuit condition and has shut down.
To clear the fault condition, press the OFF button and wait for the LED to
turn green. Remove power then rectify the short-circuit. Restore power
and try again.
LIMITED FIVE YEAR WARRANTY
Pass & Seymour will remedy any defect in workmanship or material in Pass & Seymour
products which may develop under proper and normal use within five years from date of
purchase by a consumer: (1) by repair or replacement, or, at Pass & Seymour’s option,
(2) by return of an amount equal to consumer’s purchase price. Such remedy is IN LIEU
OF ANY AND ALL EXPRESSED OR IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. Such remedy by Pass & Seymour does
not include or cover cost of labor for removal or reinstallation of the product. ALL OTHER
FURTHER ELEMENTS OF DAMAGE (INCIDENTAL OR CONSEQUENTIAL DAMAGES)
FOR BREACH OF ANY AND ALL EXPRESSED OR IMPLIED WARRANTIES INCLUDING
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
ARE EXCLUDED HEREBY. (Some states do not allow disclaimers or exclusion or limitation
of incidental or consequential damages, so the above disclaimer and limitation or exclusion
may not apply to you.) ANY IMPLIED WARRANTIES INCLUDING WHERE REQUIRED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
SHALL BE LIMITED TO THE FIVE YEAR PERIOD SET FORTH ABOVE. (Some states do
not allow limitations on how long an implied warranty lasts, so the above limitation may not
apply to you.) To ensure safety, all repairs to Pass & Seymour products must be made by
Pass & Seymour, or under its specific direction. Procedure to obtain performance of any
warranty obligation is as follows: (1) Contact Pass & Seymour, Syracuse, New York 13221,
for instructions concerning return or repair; (2) return the product to Pass & Seymour,
postage paid, with your name and address and a written description of the installation or
use of the Pass & Seymour product, and the observed defects or failure to operate, or
other claimed basis for dissatisfaction. This warranty gives you specific legal rights and you
may also have other rights which vary from state to state.
P.O. Box 4822 Syracuse, NY 13221-4822
Technical Support: 800.223.4185
www.passandseymour.com