Legrand LightSense™ Electronic, Non-Dim Switch, PSHS1 Installation guide

Type
Installation guide
CLEANING
Clean using a cloth dampened only with water and a little mild detergent.
Use of solvents or hydrocarbon-based cleaners may cause permanent damage.
TROUBLESHOOTING
The switch does not work and the status LED is flashing red
at 2Hz (10 times in 5 seconds):
The switch has detected an overload condition and has shut down.
To clear the fault condition, tap and wait for the LED to turn green.
Disconnect loads in excess of rated load and try again.
LIMITED FIVE YEAR WARRANTY
Pass & Seymour will remedy any defect in workmanship or material in Pass & Seymour
products which may develop under proper and normal use within five years from date of
purchase by a consumer: (1) by repair or replacement, or, at Pass & Seymour’s option,
(2) by return of an amount equal to consumer’s purchase price. Such remedy is IN LIEU OF
ANY AND ALL EXPRESSED OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. Such remedy by Pass & Seymour does not include or cover
cost of labor for removal or reinstallation of the product. ALL OTHER FURTHER ELEMENTS
OF DAMAGE (INCIDENTAL OR CONSEQUENTIAL DAMAGES) FOR BREACH OF ANY AND ALL
EXPRESSED OR IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE ARE EXCLUDED HEREBY. (Some states do
not allow disclaimers or exclusion or limitation of incidental or consequential damages,
so the above disclaimer and limitation or exclusion may not apply to you.) ANY IMPLIED
WARRANTIES INCLUDING WHERE REQUIRED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED TO THE FIVE YEAR PERIOD
SET FORTH ABOVE. (Some states do not allow limitations on how long an implied warranty
lasts, so the above limitation may not apply to you.) To ensure safety, all repairs to Pass
& Seymour products must be made by Pass & Seymour, or under its specific direction.
Procedure to obtain performance of any warranty obligation is as follows: (1) Contact
Pass & Seymour, Syracuse, New York 13221, for instructions concerning return or repair;
(2) return the product to Pass & Seymour, postage paid, with your name and address and
a written description of the installation or use of the Pass & Seymour product, and the
observed defects or failure to operate, or other claimed basis for dissatisfaction. This
warranty gives you specific legal rights and you may also have other rights which vary from
state to state.
P.O. Box 4822 • Syracuse, NY • 13221-4822
Technical Support: 800.223.4185
www.passandseymour.com
340812 Rev. B
PSHS1
LightSense
Electronic, Non-Dim Switch
Installation Instructions
Specifications
Voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120/277VAC, 60Hz
Load Rating . . . . . . . . . . . . . . . . . . . . . @120VAC: 0-1500W, 1/4 HP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . @277VAC: 0-3000W
Load Type Compatibility:
Non-dimmable fluorescent ballasts
Discharge lighting fixtures
Fixtures with integral dimmers
AC motors and pumps
U.S. Patent 5,804,991
Other patents pending
Syracuse, NY 13221-4822
800.223.4185
www.passandseymour.com
340812_PSHS1_InstSht_12288 4/4/07 8:52 AM Page 1
UNIT DESCRIPTION
The LightSense™ PSHS1 Electronic Switch incorporates an electro-mechanical
relay that switches the load safely using patented zero-crossing technology.
Load Types
Use the PSHS1 for the following load types:
Conventional (non-dimmable) fluorescent ballasts
Discharge lighting fixtures
Fixtures with integral dimmers
AC motors and pumps
Call 800.223.4185 for Technical Support
CAUTION
To reduce the risk of
overheating and possible
damage to other equipment, do not
install to control a receptacle.
CAUTION
Afin de réduire le risque de
surchauffe et la possibilité
d’endommager d’autres
matériels, ne pas installer
pour commander une prise.
Visit our website for FAQs: www.passandseymour.com
INSTALLATION
For ease of installation, Pass & Seymour/Legrand recommends use of a deep
wall box.
1. Disconnect power to circuit by turning circuit breaker OFF before installation.
2. Remove the existing wall plate and switch, if one is present.
3. Strip existing wires
1
/
2
"
. If two wires will be connected to the same terminal
on a LightSense™ device, both wires must be the same gauge (12AWG
or 14AWG).
4. Wire the LINE (black), LOAD, NEUT (white) and GND (green or bare) supply
and load wires to the correspondingly marked screw terminals, according to
the wiring diagram below.
5. Attach the wall plate.
6. Switch the circuit breaker back ON.
INSTALL IN COMPLIANCE WITH ALL
APPLICABLE CODES & STANDARDS.
Failure to follow these instructions may cause
personal injury or equipment damage.
CAUTION
TURN THE POWER OFF AT THE CIRCUIT BREAKER
BEFORE INSTALLING THE DEVICE.
Visit our website for FAQs: www.passandseymour.com
OPERATION
Replacing Lamps
When a lamp must be replaced, tap to turn off the circuit. If you are
conducting maintenance on the load, turn off the circuit at the circuit breaker.
Power Fail Memory
After a power failure, all LightSense™ devices automatically return to the state
that they were in immediately prior to loss of power.
When you see
in the
instructions,
touch the top
of the switch
as directed.
When you see
in the
instructions,
touch the
bottom of
the switch
as directed.
Tap once Turn circuit ON
Press and hold Turn circuit ON
Tap once Turn circuit OFF
Press and hold Turn circuit OFF
340812_PSHS1_InstSht_12288 4/4/07 8:52 AM Page 4
  • Page 1 1
  • Page 2 2

Legrand LightSense™ Electronic, Non-Dim Switch, PSHS1 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI