V-ZUG 31022 Installation guide

Type
Installation guide

This manual is also suitable for

The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order
specified.
Validity
These installation instructions apply to the following models: 31013 (GK36TIS.1F), 31014 (GK46TIMS.1F), 31016 (GK46TIS.1F),
31017 (GK46TIABS.1F), 31019 (GK46TIAS.1F), 31021 (GK46ID.1F), 31022 (GK46IABD.1F), 90A (GK46TIAKSF), 31030
(GK46TIMASF)
General notes
If installing into a combustible material, the guidelines and standards for low voltage installations and fire protection must be
strictly observed.
Identification plate
The identification plate is located next to the connection
plate.
Affix the second identification plate (supplied) in an
accessible position behind the front of the fitted
cabinet beneath the appliance.
Connection plate
Identification plate
Installation accessories supplied
Designation Article no.
Cementing-in instructions J004.133
Sealing strip set H6.2142
Accessories
Designation Article no.
Steel angle set, installation dimension 60 H6.3772
Steel angle set, installation dimension 80 H6.3774
Ventilation protective plate set for niche width 550 mm H6.1082
Ventilation protective plate set for niche width 600 mm H6.1083
Ventilation protective plate set for niche width 825 mm H6.1084
Ventilation protective plate set for niche width 900 mm H6.1085
Instant adhesive for installation of steel angle
Permabond F246 (incl. activator), 50 ml tube. From Silitech AG, 3008 Berne.
B11.502
Cement set
Complete with cleaning agent, primer type 1105, cartridge with black silicon adhesive, with nozzle.
Suitable for all absorbent worktop materials (wood and natural stones such as marble or granite).
86.3928.85
Special primer, type 107
Suitable for non-absorbent worktop materials (not suitable for polyethylene, polypropylene or
Teflon).
45.2771.76
Installation instructions
J31013.123-2
17.04.14
Induction glass ceramic hob
Frameless, for flush installation
1
Electrical connection
Electrical connections must be carried out by trained electricians in accordance with the guidelines and standards for low-
voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug
and socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles
switching are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors
ensure safe and fault-free operation. After installation, live parts and cables with basic insulation must not be accessible.
Check old installations.
The appliance is designed for use up to a max. altitude of 2000 m above sea level.
See the identification plate for information on the necessary mains voltage, type of current and fuse protection.
The appliance is equipped with a mains cable that should be connected to a distribution box by the customer.
600/550
900/825
Installation pipe
Distribution box
Clamp
brown + black
blue
yellow/green
black
blue
yellow/green
brown
L2
L1
N
N
L1
PE/
PE/
400 V 2N~
230 V~
Error message U400
Incorrect connection:
Pole conductor connected to connection terminal for neutral conductor.
Quickly disconnect the appliance from the mains!
Ventilation
In order to guarantee good ventilation, a space of
at least 17.5 mm in height is necessary beneath
the appliance.
1. The back wall of the base unit in the area of
the worktop cut-out must be open to guar-
antee continuous air circulation over the
ventilation slits.
2. Alternatively, air circulation inside the cabinet
can be provided for by a concealed fresh air
intake.
In order that enough cold air can be drawn in,
there must be a continuous circulation of
fresh air that extends outside the cabinet.
≥ 15
21
Installation instructions
J31013.123-2
17.04.14
Induction glass ceramic hob
Frameless, for flush installation
2
Installation
Indications
The worktop must be flat.
In order to guarantee good ventilation, a space of at least 17.5 mm in height is necessary beneath the appliance.
Fitting
The layout of the cooking zones on the hob to be built in may differ from the illustrated hob!
501
571
761
501
767 ±1
Z
507 ±1
577 ±1
600
600/550
600
507 ±1
Z
(560/750)
(490)
R5
R0–5
600/550
825/900
0
-0.5
0
-1
(30)
≥ 41.5
≥ 41.5
(30)
≥ 41.5
≥ 41.5
GK36TIS.1F, GK46TIS.1F
GK46ID.1F, GK46TIMS.1F
GK46TIAS.1F, GK46TIABS.1F, GK46IABD.1F,
GK46TIAKSF, GK46TIMASF
8.5
8.5
50
50
8.5
0
+1
8.5
0
+1
For symmetrical fitting
it is not necessary to
cut out the side walls.
Detail Z
Steel angle bonded or srew mounted
(for adhesive see ‘Accessories’)
1. Create an accurate cut-out.
The mounting surface can be recessed by installing wood or stone bars or produced using the steel angle set (see ’Accesso-
ries’).
Access to the appliance from below must be guaranteed over the entire cut-out surface. For servicing, the induction gener-
ator with the mounting plate can be removed from below. Touch protection must be removable by unscrewing from under-
neath.
2. Prepare the cut-out and the appliance according to the information in the accompanying cementing-in instructions.
3. Carefully cement the appliance in place and allow the silicon cement joints to dry for at least 24 hours.
4. Where necessary establish the mains supply connection before inserting the appliance.
Installation instructions
J31013.123-2
17.04.14
Induction glass ceramic hob
Frameless, for flush installation
3
Cool air intake if installed over a drawer or cabinet
In order to guarantee good ventilation, a space of at least 17.5 mm in height is necessary beneath the appliance.
≥ 5
≥ 15
(30)
600/550
900/825
≥ 25 cm²
≥ 50
≥ 67.5
Drawer Centre of fan
Air gap over the entire cabinet element width
Necessary space for the ventilation
below the worktop required
Hobs with dial control require protective intermediate base.
Installing the protective plate with a 3 mm ventilation gap at the front (see ’Accessories’)
A protective plate is necessary for the adequate ventilation of the hob.
The distance between the underside of the appliance and the protective plate must be at least 17.5 mm.
A protective plate cannot be installed with induction hobs that have dial controls.
393
(30)
67.5
5..10
55.5
56
Ø4
15
(17.5)
50
3
0.5
2.5
Caution: mains cable
must not touch
protective plate!
Well-fitting seal over
width of cabinet element
Air gap over entire width of
cabinet element
17 cm²
According
to template
Drawer
Fan
Installation instructions
J31013.123-2
17.04.14
Induction glass ceramic hob
Frameless, for flush installation
4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

V-ZUG 31022 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document