MK K1522WHILV Installation guide

Type
Installation guide

This manual is also suitable for

FEATURES
N
OTE:
-
For correct operation, it is very important that the
t
otal load
M
UST NOT
b
e less than the minimum power/load
rating
AND MUST NOT be greater than the maximum
p
ower/load rating marked on the dimmer. This rating is shown
in Watts (W) & Volt/Amps (VA) on the back of each dimmer.
Soft Start When the dimmer is switched on, the brightness of
the lights will be gradually increased over a period of 1 to 3
seconds until a pre-selected level (set by the control knob, is
attained.
This feature alone will help to greatly extend the life
expectancy of filament lamps, by avoiding the initial power
surge.
Overload Protection If any of the dimmers are overloaded,
the output to the lamp(s) will be automatically reduced to
provide protection against damage to the dimmer and to the
installation. An Intelligent Power Monitoring System (IPMS) is
used to provide protection from overload by reducing power
levels to the load(s) in stages according to the severity of the
overload, as follows: - (Note; The first figures given are the
appr
oximate load on the dimmer as a percentage of its
maximum rating.)
4
8
3
7
2
6
Intelligent Dimmer Switch
These dimmers comply with both
BS EN 60669-2-1 & BS EN 55015
Please keep this leaflet for future reference
5
SAFETY INSTRUCTIONS
This product must be installed by a competent person in
accordance with the current editions of the IEE Wiring
Regulations (BS7671) and Buildings Regulations. If in any
doubt, consult a qualified electrician.
To prevent electrocution, do not work on any appliance
live. Turn off the mains supply before commencing work.
If this product has a metal front plate it must be earthed.
To prevent fire hazard do not exceed the rated load
specified for the product.
The minimum box depth required for white plastic dimmers
when using the supplied pattress is 16mm.
Single white plastic dimmers without a pattress, as well as
all other dimmers with front plates of at least 9mm deep,
the minimum box depth required is 25mm.
Double dimmer in a one-gang plate require a minimum box
depth of 35mm
44157 PL Ed. 2
All dimmers with a front plate less than 9mm deep require
a
minimum box depth of 35mm.
Dimmer switches must not be used in bathrooms,
washrooms or any location subject to splashes of water
condensation or dampness.
Product and packaging should be disposed of via standard
refuse facilities at the end of their life.
GENERAL INFORMATION
Dimmers are available with one or two modules mounted
on the same fr
ont plate. Dependent on power output, they
are also available in one or two gang front plates with
single or double dimmers.
The control knob(s) has a push on/push off action. Rotation
of the knob(s) will vary the light setting.
The terms one-way and two-way switching refer to the
mode of switching required in an installation.
One-way switching is used in installations where a circuit is
contr
olled by just one switch. e.g. controlling one light
fr
om a single switch which is either on or off.
See Figur
e 1
.
Two-way switching is applied to installations where a circuit
is often controlled by two switches, e.g. controlling a light
circuit from two switches located some distance apart, one
switch at one end of the room and another switch at the
other end.
MK intelligent dimmers have two-way switching, which
a
llows their use in either application.
In a two-way installation as shown in
f
igure 2
,
only one
dimmer must be used. A standard 2-way switch must be
u
sed in the other position.
As long as the rotary control knob is not turned, when
pressed, the dimmer will switch on at the previously set
light level. This is also true in the two-way set up described
above and shown in
Figure 2, even when operated by the
remote switch.
To avoid damage to the dimmer, do not operate outside its
maximum and minimum wattage, or Volt/Ampere limits.
These limits are given on the rear of the dimmer, on the
packaging and in the Specification section below.
The dimmers should not be installed where an ambient
temperature is outside the 0ºC & 40ºC limits.
NOTE: It is normal for the front of the dimmer to become
quite warm in use, the temperature reached being
dependent upon the lamp load and the ambient
temperature.
MK dimmers employ the latest technology, using micro-
controller based circuitry to provide the features described
in the following section.
Up to 125 Load will receive maximum power continuously.
>125 to 150 Output to the load will be reduced to 50% of
the maximum after a delay of appr
oximately 20
seconds after switch on.
>150 to 200
Output to the load will be reduced to the
minimum setting after a delay of approximately
20 seconds after switch on.
>200 Output will be disabled (dimmer will switch off)
almost instantaneously after switch on.
Nor
mal operation will r
esume after the dimmer is switched of
f
and turned back on, with the load adjusted to be within its
maximum and minimum ratings.
COMPATIBILITY WITH LOW VOLTAGE LIGHTING SYSTEMS
One for
m of Low V
oltage Lighting System comprises a good
quality wir
e wound step down transfor
mer for Low V
oltage
Lighting loaded with suitable Low Voltage Tungsten Halogen
lamps(s). Another for
m comprises a fully dimmable Electr
onic
Transformer, specifically designed for dimming using phase
delay, phase-cut-on or leading edge type of dimmer, loaded
with suitable Low Voltage Tungsten Halogen lamp(s).
The dimmers are designed to work with a large number of
fully
dimmable
, good quality, Wire Wound as well as Electronic Low
V
oltage Lighting T
ransformers, which are recommended for
use with phase delay, or leading edge type dimmers.
DO NOT
use transfor
mers that are only suitable for use with phase cut,
phase cut-off, or trailing edge type dimmers.
So as not to compr
omise system safety
, MK r
ecommend that
transformers have built in thermal protection and have over-
current protection on both primary and secondary circuits. The
L
V system must comply with the EMC dir
ective and car
r
y the
CE marking. The total
transformer load on the dimmer
(obtained by adding together the load rating of each
transformer) must be within the minimum and maximum load
rating W/V
A of the dimmer.
In addition, transformers MUST be loaded correctly and they
must provide correct loading to the dimmer, within its specified
minimum and maximum Power/Load ratings.
For optimum performance of the dimmer, load each
transformer with lamp(s) so that the total load on each
transfor
mer is between 75 - 100% of its rated load. (e.g. load a
transfor
mer rated at 25 to 105W/V
A with lamps, so that their
total wattage adds up to 80 to 105 watts.)
NOTE: Some transformers for low voltage lighting have
input circuits which, when used with phase delay type of
dimmers, r
esult in ver
y high peak power pulses in the
dimmer. To avoid overloading and possible malfunctioning
of the dimmer
, do not connect more than the maximum
number of transformers specified below, to any one
dimmer
.
Up to 300W/240VA dimmers - Max. 4 transformers.
Over 300W/240V
A dimmers - Max. 5 transformers.
The dimmer's micro-controller based circuitry monitors the
essentially a.c. supply conditions r
equir
ed for wir
e wound
transformers and if a d.c. supply condition is detected due to
some fault, which could overheat and damage the transformer,
the dimmer automatically turns off the supply to the
transformer after a short period.
COMPATIBILITY WITH MAINS VOLTAGE HALOGEN LAMPS
The soft start feature incorporated in this range of dimmers
makes them ideally suited to drive mains voltage halogen
lamps, which have inherently high inrush currents at switch on.
By using a soft star
t with this type of load(s), not only is the
dimmer protected against premature failure but the lamp(s)
load also benefits fr
om pr
olonged life due to limitation of the
life shortening high inrush currents at switch on.
Failur
e to comply with the pr
e-r
equisites given above could
compromise System Safety.
None of these MK dimmers are suitable for use with
fluorescent lighting, including energy saving lamps.
44157 PL Dimmer Switch Ed.2 2/2/2006 11:32 am Page 1
removing the old switch. This should make it far easier to
i
nstall the new dimmer.
7
. For better thermal management, the dimmer should
preferably be installed with its terminals at the bottom.
8
. A one-way installation is where simple on or off switching
and dimming of one light is required from a single switch.
9. Strip back the outer cable sheath and trim the inner cables
to the appropriate length.
10. Carefully strip the inner cable insulation to expose 8mm of
the conductor.
11. All live conductors should have red (brown) sleeving. This is
achieved by fitting a short length of sleeving over the end
of any lead that has black insulation.
12. Ensure each wire is connected to the appropriate terminal,
as shown in the typical diagram -
Figure 1.
13. When an earth lead is installed, ensure it is connected to
the terminal in the mounting box. A length of green/yellow
sleeve must be fitted over all earth conductors.
14. If the product has a metal front plate, an earth lead
MUST
be connected between the earth terminal on the dimmer
and the earth terminal in the back box. Again a length of
green/yellow sleeving must be used over the bare earth
conductor.
121110
14
9
13
INSTALLING THE DIMMER IN A ONE-WAY SITUATION
1
. Make sure the previous sections of these instructions are
f
ully understood and complied with prior to installing the
dimmer.
2
. Please note; the colour codes used in the UK prior to April
2004 are as follows: -
Live = RED Neutral = BLACK
In all other areas of the EU, as well as new build installations in
the UK after April 2004, the colour codes used are: -
Live = BROWN
Neutral = BLUE
The first colour indicated in the following text will be that used
prior to April 2004. The second colour, shown in brackets, is
the colour used after April 2004.
3. Some products have the fixing screws clipped to the rear of
the product. These should be unclipped before installing
the product.
4. Ensure the mounting box is firmly fixed to the wall.
5. If the mounting box has four fixing lugs, it may be
necessary to bend the top and bottom lugs back, so as to
clear the back of the dimmer moulding.
6. If replacing an existing dimmer or switch, always take
careful note of the cables and terminal descriptions before
Figure 2 - typical two-way switch circuit
(1 dimmer only must be used)
COM L2 L1
L1
L2 COM
Load ’L‘ fr
om mains
supply
N
Dimmer
Figure 1 - typical one-way switch circuit
Load
Dimmer
2-way
Switch
COM
L1 L2
’L‘ from mains
supply
N
M
in Max Min Max
Wattage Wattage W or VA W or VA
Single 40 300 40 240 4
Double 40 300 40 240 4
Single 60 500 60 400 5
Double 60 450 60 360 5
SPECIFICATION
N
ominal mains supply voltage . . . . . . . . . .230Volts a.c.
M
ax. acceptable mains fluctuation . . . . . . .216 to 253V a.c.
Mains frequency . . . . . . . . . . . . . . . . . . . . .50Hz ± 3Hz
A
mbient temperature range . . . . . . . . . . . .0°C to 40°C
These dimmers can be used with the following: -
Fused GLS Tungsten Filament lamps to BS EN60064 &
BS EN60432-1, rated at 230/240 volts only.
Mains rated Halogen lamps with GU10 bases, to BS
EN60064 & BS EN60432-2.
Wire wound Low Voltage transformer(s) of good quality,
either laminated or toroidal.
Fully dimmable Electronic Transformer(s) suitable for
mains input voltage range specified above, used in
conjunction with Low Voltage Halogen lamp(s).
NOTE: Transformers must be suitable for dimming; using
the leading edge phase delay, and not just the trailing edge
phase cut type of dimmers.
Under no cir
cumstances exceed the minimum / maximum
ratings given in the chart shown on page 10.
15. If an earth terminal is not present on the dimmer or
mounting box and earth protection is not required, then
any ear
th wir
e must be fully insulated by an appropriate
means.
16.
Carefully push the wired unit back into the back box,
ensuring cables are not trapped or pinched.
17.
Using the scr
ews pr
ovided, mount the dimmer onto the
back box, making sure the screws are not over tightened so
as to prevent damage or distortion to the front plate.
Adjust so the fr
ont plate is squar
e on the wall.
18.When carrying out insulation resistance testing, first
disconnect the dimmer. Failing to do this could damage the
dimmer and could also give spurious insulation readings.
INSTALLING THE DIMMER IN A TWO-WAY SITUATION
1. A two-way installation is when a dimmer is used in
conjunction with a two-way switch, to contr
ol one light
from more than one position.
2.
If replacing an old switch, carefully note the terminals to
which each wire is connected. (com., L1, L2 etc.) This will
help to ensur
e cor
r
ect connection to the new dimmer
.
3. Follow the instructions for installing the dimmer switch in a
one-way situation given above, except this time using the
cir
cuit shown in
Figur
e 2
for the ter
minal positions.
CLEANING FRONT PLATES
In order to protect the surface finish quality of the front plate,
periodic cleaning should only consist of polishing with a dry lint
fr
ee soft cloth. On no account should abrasive or domestic
cleaners be used.
1. On front plates mounting multiple dimmers, the minimum
/ maximum W and VA ratings given are for each dimmer.
2. The minimum load of the transformer should not be less than the
Min. Power/Load Ratin
g
g
of the
d
d
i
i
m
m
m
m
e
e
r
r
, even if the transformer
has a lower Min. power/Load rating (e.g. 20W or VA).
3. If the transformer is loaded with more than one lamp to
achieve the minimum load in accor
dance with the Min.
Power/Load Rating, then on failure of one or more of the
lamps, the total load may fall
below the Min. Power/Load
Rating of the dimmer
, which could result in the system not
functioning correctly.
Number
of
mounted
on plate
Power/Load rating
with mains Tungsten
G
LS lamps
P
ower/Load rating
with mains Tungsten
H
alogen Lamps and
LV Transformers
Max No.
T
ransfor-
mers per
dimmer
15
®
MK Electric
Novar ED&S Ltd
The Arnold Centre, Paycocke Road, Basildon,
Essex SS14 3EA. U.K.
Tel: +44 (0)1268 563000
Fax: 01268 563405
(UK Sales)
Fax: +44 (0) 1268 563360 (International)
email: technical@novar.com
web site: www.mkelectric.co.uk
Technical queries should be made to:
MK Electric, Technical Sales and Services Department
The Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA
Tel: +44 (0)1268 563720 Fax: +44 (0)1268 563064
All marks in this document identified with a R or TM symbol
adjacent to the mark are Trade Marks of Novar ED&S Limited.
44157 PL Dimmer Switch Ed.2 2/2/2006 11:32 am Page 5
  • Page 1 1
  • Page 2 2

MK K1522WHILV Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI