TFC-200

Goodway TFC-200 User guide

  • Hello! I am an AI chatbot trained to assist you with the Goodway TFC-200 User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What should be done before using the Goodway TFC-200?
    How do I start the pre-rinsing process?
    How do I apply the chemical?
    How do I rinse the tower after applying the chemical?
    What steps should be taken after use?
TFC-200 Quick Start Guide
PLEASE REVIEW
IMPORTANT SAFETY
INSTRUCTIONS
LOCATED IN
OPERATORS MANUAL
Proper Startup
Essentials
* Accessories sold separately
Raise dip tube for chemical
siphoning. Lock/ unlock collar
as needed.
1
Connect blue chemical hose to quick connect
output on the back of the unit, then connect the
spray gun to female quick connect.
3
Insert
chemical
container
& strap in
securely.
Lower the
dip tube.
2
Connect water hose to water inlet
on the spray gun. Turn on
water supply.
4
Pull trigger on the spray gun until water starts coming out of the
gun. Connect proper nozzle based on the nozzle chart.
5
Connect GCFI to
outlet, test and
reset to ensure
its functioning.
6
Attach pre-rinse nozzle to spray gun (refer
to nozzle chart). Rotate ball valve lever to
RINSE setting. Flip toggle switch to RINSE/
MIX to turn on unit. To turn off, toggle
switch up to center position.
• Thoroughlyrinsetowerll.
Attach chemical nozzle to spray gun (refer to
nozzle chart). Rotate ball valve lever to CHEMICAL
setting. Flip toggle switch to CHEMICAL to turn
on unit. To turn off, toggle switch down to
center position.
• Thoroughlyapplychemicaltotowerll.
IMPORTANT: ALLOW CHEMICAL TO DWELL
ON TOWER FILL FOR AT LEAST ONE HOUR.
PRE-RINSING
TOWER FILL
CHEMICAL APPLICATION
GOODWAY® TECHNOLOGIES CORPORATION
420 West Avenue, Stamford, CT 06902 USA
Tel: 203-359-4708 · Toll-Free Tel: 800-243-7932
Fax: 203-359-9601 · Toll-Free Fax: 800-359-9625
Email: goodway@goodway.com
Visit: www.goodway.com
HVAC & FACILITY MAINTENANCE SOLUTIONS
RINSE APPLICATION
SHUTDOWN
Attach large black rinse nozzle to spray gun (refer
to nozzle chart). Rotate ball valve lever to RINSE
setting. Flip toggle switch to RINSE/MIX to turn on
unit. To turn off, toggle switch up to
center position.
Aggressively rinse tower till until chemical is
thoroughly washed away.
Repeat Steps 1-3, if desired, for a better clean.
After use, raise dip tube and place cap on chemical container before
unstrapping and removing from rear compartment.
CAUTION: Do not travel with chemical container inside unit!
Run clean water through the unit from both the water intake and a clean
bucket of water through the dip tube to rinse internal components. Neutralize
cooling tower water by adding one 25 pound pail of Goodway Scalebreak
Neutralizer per each 5 gallon container of ScaleBreak-Gel™ to the water
in the basin to achieve a neutral pH. Refer to Operation Manual for more
detailed instructions.
/