SICK Host-Guest Plug Operating instructions

Type
Operating instructions
O P E R A T I N G I N S T R U C T I O N S
HostGuest Plug
for C4000
safety light curtains
GB
SICK AG • Industrial Safety Systems
Sebastian-Kneipp-Straße 1
D-79183 Waldkirch • www.sick.com
8011556/23-02-06 • RV/KE
Printed in Germany (03.06) • All rights
reserved • Product properties and technical
specifications given do not represent any form
of warranty or assurance of properties.
1 About this document
This device manual is only valid in conjunction
with the operating instructions for the
corresponding C4000 safety light curtain.
2 On safety
Safety notes
Use Host9Guest Plug only with C4000
safety light curtains approved for this
purpose.
After using Host9Guest Plug you must
perform all checks before initial
commissioning in conjunction with
C4000. Read the chapter on
“Commissioning” in the relevant
operating instructions.
This device manual must be given to
the user of the Host9Guest Plug
together with the relevant operating
instructions for the C4000.
3 Product description
Host9Guest Plug is used to reset a system
position saved in C4000.
If safety light curtains are used in a cascaded
system, the system position (Host, Guest1 or
Guest2) is stored permanently in the device
memory of the C4000. The device can no
longer be used as a standalone device or in a
different system position.
All other configured functions such as EDM,
PSDI, blanking, etc. are not reset by
Host9Guest Plug and remain unchanged.
4 Battery exchange
Host9Guest Plug indicates a low battery level
with a flashing yellow LED.
Notes
Remove the battery before disposing of the
Host9Guest Plug.
Dispose of removed batteries in accordance
with applicable legislation.
Fig. 1: Resetting a C4000
Fig. 2: Battery exchange
5 Error messages
In the event of an error, the left LED will flash
at 1 Hz.
Fig. 3: Error messages
Possible cause Solution
C4000 firmware
before version 3.xx
Configure the device
with CDS
C4000 in the lock-
out status
Disable lock-out as
described in the op-
erating instructions
C4000 79segment
display shows
Configure the device
with CDS
6 Data sheet
Enclosure rating IP 41
Dimensions
(L × W × H)
96 × 47 × 24 mm
Battery type Lithium button cell
CR 2032, 3.0 V
Operating
temperature
0 … +55 °C
Storage temperature –25 … +70 °C
7 Ordering information
7.1 Delivery
7.2 Host)Guest Plug
Part Part number
Host9Guest Plug 1029717
7.3 Accessories
Part Part number
Battery 6010378
Protective cap 5318293
Cable tie 5318367
Wall mount 5318443
Fig. 4: Accessories
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

SICK Host-Guest Plug Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI