Kutai DSP-30 Owner's manual

  • I have carefully reviewed the user manual for the KUTAI DSP-30 Power Meter Display Module. This document outlines the device's functionality in displaying real-time voltage, current, and power, along with instructions for programming and calibration. I am ready to answer your questions about the DSP-30.
  • How can I change the display mode?
    How do I enter program mode?
    How can I adjust Voltage and Current?
KUTAI ELECTRONICS INDUSTRY CO., LTD.
TEL : +886-7-8121771 FAX : +886-7-8121775 Website : www.kutai.com.tw
Headquarters : No.3, Ln. 201, Qianfu St., Qianzhen Dist., Kaohsiung City 80664, Taiwan
L
23
L
12
L
31
VL
23
L
12
L
31
V
L
23
L
12
L
31
VL
23
L
12
L
31
V
L23 Fix Mode
L31 Fix Mode
L12 Fix Mode
Cyclic Mode
DSP-30
Percent Power Meter Display Module
Front Panel Display
DSP-30 Display panel has three four Digits bright LED’s that
shows (RMS) Voltage, Amps and percentage of full Power. The
user can easily read the real time 3 phase Voltage, Amps and
the percent of power that load is using now.
Programming Mode
There are three push buttons on the front panel for 100% full
power range setting. User need to set the full power range in
KVA before used. The buttons function description show as
below.
Program keyPress it will into program mode.
V
Up keyPress it will increase the setting value.
A
Down keyPress it will decrease the setting value.
How to Program the DSP-30 (1KVA / Unit)
Step-1Press the program key for 2 seconds and then the
DSP-30 will into program mode and the screen show as
below.
Step-2Use Up or Down key for 100% power range setting.
Step-3Press program key again to exit the program mode.
Display Function
The operator can change the voltage and current display to be
fixed or cycling from phase to phase by simply using the button
next to each display.
To change the display mode, press the button next to it. See diagram.
Rear Panel Layout
Recommended Cut-Out 66 66 ± 0.5 mm
Voltage and Current Adjustment (If Necessary)
In the back of the DSP-30 module we have 4 push buttons for voltage
V & V and current A & A adjustment. The Module comes
factory tested and calibrated and normally no changes are necessary.
But if any modifications are required, follow the procedures below.
Voltage Adjustment
(Please use and accurate RMS Voltmeter as your reference)
1. Start the generator. Set your reference AC voltage using your
Voltmeter.
2. Select the desire phase you need to re-calibrate using the front
display V button on the display and hold.
3. Repeatedly press V) or V
on back of module to adjust
the displayed voltage equivalent to your voltmeter.
4. Release the front V button. The LED display will flash
continuously for 5 seconds.
5. After for 5 seconds then the system will automatically record
the new setting and return to normal.
6. If the display shows FAIL the setting is invalid, and step 3
must be repeated.
Current Adjustment Procedure
(Please use Standard RMS Current meter for readings)
1. Set the dip switches to the correct CT in use.
2. Start the generator. And wait for the generator to stabilize.
3. Slowly add load to the genset until maximum rated load
current is reached for the CT in use.
4. Select desire phase current to calibrate using the front A button.
5. Repeatedly press A
or A on the back panel to adjusts
the displayed current to its equivalent on the current meter.
6. Release the front A button. The LED on the display will
flash continuously for 5 seconds.
7. After 5 seconds the system will automatically record the new
setting and return to normal.
8. If the panel display shows FAIL then the previous setting is
invalid, please return to step 5.
Setting The CT Value
Set the 5 pin dip switch for the CT (Current Transformer) and the
system phase you are using.
Dip Switch Setting Reference Diagram
Specification
ITEM
DESCRIPTION
DC Supply
9.0 ~ 36 V
Alternator Input Range
10 ~ 500VAC(Ph-Ph)
Alternator Input Frequency
50/60 Hz
CT Burden
Above 2.5VA
CT Secondary
5A
Max. CT Rated
3000A / 5A
Operating Temperature
-20 C to 60 C
Relative Humidity
90% or Below
Power Consumption
Under 2W
Weight
200 gram
Three Phase System Standard Wiring Diagram
Single Phase System Standard Wiring Diagram
Please link to http://www.kutai.com.tw for detailed manual
Battery
F4
+
1A
L1
J1-2
L3 L2
J1-6 J1-4
G
0.5A
F3
0.5A0.5A
F1F2
L1
L2
L3
L1
CT-L1
J2-15
DSP-30 Meter
J2-8 J2-9
V-V+
J2-12 J2-13 J2-14
K
LK
K L
CT-L2
L
CT-L3 L3
L2 LOAD
50/5A
100/5A
150/5A
200/5A
250/5A
300/5A
400/5A
500/5A
600/5A
800/5A
1000/5A
1200/5A
1500/5A
1600/5A
2000/5A
3000/5A
Programmer Table =ON =OFF
System Phase select 5
= 3 Phase
5
= 1 Phase
1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
Current Transformer (CT)
J1-2J1-4
F4
1A
V+
J2-8 J2-9
V-
F2
0.5A 0.5A
F1
L2 L1
J2-12 J2-15
L1
K L
CT-L1 L1
L2
DSP-30 Meter
LOAD
GL2
Battery
+
/