Alpha Breaker Panels Owner's manual

Type
Owner's manual

Alpha Breaker Panels are a line of high-quality, feature-rich breaker panels that are perfect for a variety of residential and commercial applications. These panels are designed to provide reliable power distribution and protection, and they come with a variety of features that make them easy to install and use.

Some of the key features of Alpha Breaker Panels include:

  • Front access: All breakers are accessible from the front of the panel, making it easy to reset or replace breakers without having to remove the panel from the wall.
  • Plug-in breakers: The breakers are plug-in, which makes them easy to install and replace.

Alpha Breaker Panels are a line of high-quality, feature-rich breaker panels that are perfect for a variety of residential and commercial applications. These panels are designed to provide reliable power distribution and protection, and they come with a variety of features that make them easy to install and use.

Some of the key features of Alpha Breaker Panels include:

  • Front access: All breakers are accessible from the front of the panel, making it easy to reset or replace breakers without having to remove the panel from the wall.
  • Plug-in breakers: The breakers are plug-in, which makes them easy to install and replace.
Plug-in Breaker Panel, Front Access
16 Position, 19" and 23" Mounting
020-588-B2
Argus Technologies Ltd. Visit www.argus.ca
Burnaby, British Columbia. Telephone: 604 436 5900 Fax: 604 436 1233
Argus Technologies reserves the right to make changes to the products and information contained in this document without notice.
Copyright 2008 Argus Technologies Ltd. Argus
®
is a registered trademark of Argus Technologies Ltd. All Rights Reserved.
Printed in Canada.
This page intentionally left blank.
Argus Technologies Ltd. 020-588-B2 Rev D WC
Printed in Canada. © 2007 Argus Technologies Ltd. ARGUS is a registered trademark of Argus Technologies Ltd. All Rights Reserved.
Plug-in Breaker Panel, Front Access
16 Position, 19” and 23” Mounting
020-588-B2
The following documents and drawings are included in this manual to provide the necessary information required for
installation, operation and fault diagnosis of the unit:
• Specifications: 020-588-B1 Rev C
• Warranty Policy: 048-507-10
• Important Safety Instructions: 020-588-C0 Rev A
• Schematic: 020-588-05
• Outline Drawing: 020-588-06
• Customer Connections: 020-588-08
• Schematic, Breaker Alarm PCB: 707-104-05
• Factory Service Information: 048-527-10
SPECIFICATIONS FOR ARGUS’ FRONT ACCESS PLUG-IN BREAKER PANELS
Argus Technologies Ltd. 020-588-B1 Rev C WC
Printed in Canada. © 2007 Argus Technologies Ltd. ARGUS is a registered trademark of Argus Technologies Ltd. All Rights Reserved. Page 1 of 2
General
Alarm: Jumper selectable Form A (normally open) or Form B (normally closed) contacts
Default is Form A
Input Termination: 2 sets of 2x3/8”-16 tapped holes on 1” centers
Load Termination: 1 set of 2x1/4”-20 tapped holes on 5/8” centers ( 1 per breaker)
Ground Bar Option: Input term. 4 sets 2x3/8”-16 tapped holes on 1” centers
Load term. 1set 2x1/4”-20 tapped holes on 5/8” centers ( 1 per breaker)
Breaker Option: AM-type mid-trip plug-in breaker, 5/16” bullet-style terminals;
No alarm jumper wires are required
Load Disconnect Option: 24Vdc or 48Vdc; two required if using an A/B feed
020-588-20
Shelf Size: 221mm H x 483mm W x 188mm D
(8.7” H x 19” W x 7.4” D)
[all dimensions do not include mounting brackets]
Mounting: 19” and 23” rack
020-589-20
Shelf Size: 221mm H x 584mm W x 188mm D
(8.7” H x 23” W x 7.4” D)
[all dimensions do not include mounting brackets]
Mounting: 23” rack
Installation Notes
1. CAUTION: When no load is connected and the breaker is turned off, there will be –48 Volts on the
output due to the alarm circuitry. This circuitry can only source 2.2mA.
2. Input cables 4/0 maximum recommended.
3. It is recommended to leave 2 rack units (RU) above for cabling; 3 RU if ground bar option is used.
4. See drawings included with this manual for more information. Cross-reference list options on panel to
drawings to verify exact configuration.
SPECIFICATIONS FOR ARGUS’ FRONT ACCESS PLUG-IN BREAKER PANELS CONTINUED
Argus Technologies Ltd. 020-588-B1 Rev C WC
Printed in Canada. © 2007 Argus Technologies Ltd. ARGUS is a registered trademark of Argus Technologies Ltd. All Rights Reserved. Page 2 of 2
Part Numbers and List Options
This product is available to order under the following part numbers and list options:
Description Part Number/List Option
Breaker Panel, 16-Position, 19” and 23” Mounting, Front Access.............................................................020-588-20
Breaker Panel, 20-Position, 23” Mounting, Front Access..........................................................................020-589-20
Basic unit..............................................................................................................................................................List 0
24Vdc...................................................................................................................................................................List 1
48Vdc...................................................................................................................................................................List 2
Form B contacts.................................................................................................................................................List 11
Front access ground bar....................................................................................................................................List 17
19”/23” Rack mount, 1.75” racks, blue/gray, English.............................................................................List 19/23,50*
23” Rack mount, blue/gray, English...........................................................................................................List 23,50**
23” Flush mount, blue/gray, English ...........................................................................................................List 25,50*
23” Wall mount...........................................................................................................................................List 26,50**
24Vdc Load disconnect......................................................................................................................................List 71
48Vdc Load disconnect......................................................................................................................................List 72
Split (A/B) rear input (hot), requires List 86........................................................................................................List 80
Blank plate .........................................................................................................................................................List 81
Single shunt mounting (B-series), rear input......................................................................................................List 83
Dual shunt mounting (B-series) .........................................................................................................................List 84
Rear input (hot)..................................................................................................................................................List 86
Front input (hot)..................................................................................................................................................List 87
Hanger bracket, mounting...............................................................................................................................List 95**
Breakers:
5A....................................................................................................................................................... List 100
10A..................................................................................................................................................... List 101
20A..................................................................................................................................................... List 102
30A..................................................................................................................................................... List 103
40A..................................................................................................................................................... List 104
50A..................................................................................................................................................... List 105
60A..................................................................................................................................................... List 106
70A..................................................................................................................................................... List 107
80A..................................................................................................................................................... List 108
90A..................................................................................................................................................... List 109
100A................................................................................................................................................... List 110
15A..................................................................................................................................................... List 111
25A..................................................................................................................................................... List 112
* 020-588-20 only
** 020-589-20 only
The above information is valid at the time of publication. Consult factory for up-to-date ordering information. Specifications are subject to change without notice.
Warranty Policy
Argus Technologies Ltd. warrants all equipment manufactured by it to be free from defects in parts
and labor, excluding third party OEM materials (example: air conditioners, batteries), for a period of
two years from the date of shipment from the factory. For third party products the OEM’s warranty
shall apply. The liability of Argus applies solely to repairing, replacing or issuing credit (at Argus’ sole
discretion) for any equipment manufactured by it and returned by the customer during the warranty
period. The terms of the warranty are Ex Works (EXW) from Argus’ factory service location.
Argus reserves the right to void the warranty if:
(1) identification marks or serial numbers are removed or altered in any way,
(2) invoice is unpaid, or
(3) defect is the result of misuse, neglect, improper installation, environmental
conditions, non-authorized repair, alteration or accident.
Argus shall not be liable to the customer or other parties for any loss of profits, loss of use, costs for
removal or installation of defective equipment, damages or consequential damages based upon
equipment failure during or after the warranty period. There shall be no other obligations either
expressed or implied. Argus will not honor warranties for batteries and other third party products
without prior written Argus authorization.
Freight Policy
Customer is responsible for all shipping and handling charges (COD and freight collect will not be
accepted without prior approval from Argus Technologies).
Terms of Payment (North America)
Payment terms are net 30 days subject to prior credit approval. All other orders require payment
before shipping.
Terms of Payment (International)
Payment terms are subject to prior approval and are typically through Tele-Transfer.
Return Material Policy
Our RMA policy is designed to ensure prompt, efficient and high quality factory service. A Return
Material Authorization (RMA) number must be obtained before products can be accepted for
servicing by the Argus factory. For returns to an authorized service center (refer to “Authorized
Service Centers” for locations), please consult the individual service center for specific return policies
and instructions.
To obtain a RMA number for a factory return, customers must call the appropriate location with the
product serial and model number, as well as a brief description of the problem, shipment instructions
and billing details.
The original packing container should be used whenever possible. Both the shipping documents
and the outside of the box must have the RMA # clearly marked and the product shipped prepaid to
the Argus factory service center. Argus will endeavor to repair products within five working days of
receipt. Repairs to the returned product are warranted for a period of six months. A service charge
may be applied if no fault is found in the returned product. Argus will not accept products without an
RMA number.
Business Hours
Argus North American office hours are 7:30 am to 5:00 pm (Pacific Standard Time) Monday to Friday.
WARRANTY AND REPAIR INFORMATION
Canada and USA toll free 24 hour emergency technical support:
+
1 888 GO ARGUS (462 7487) Outside North America: +1 604 436 5547
Factory Service Centers
Canada and International
Argus Technologies Ltd.
ATTN: RMA Returns
7033 Antrim Avenue
Burnaby, BC, V5J 4M5 Canada
Tel: +1 604 436 5900
Fax:
+1 604 436 1233
Email: returns@argusdcpower.com
USA
Argus Technologies Inc.
ATTN: RMA Returns
3116 Mercer Avenue
Bellingham, WA, 98225 USA
Tel: +1-360 756 4904
Fax:
+1-360 647 0498
Email: returns-usa@argusdcpower.com
Asia-Pacific
PCM Electronics (Dong Guan) Co., Ltd.
Hongli Industrial Area, Miaobian, Liaobu Town,
Dongguan City, Guangdong Province,
523400 China
Tel: +86 755 8895 3310
Fax:
+86 755 8895 3307
Authorized Service Center
Argentina
Argus Technologies de Argentina
Belen 315, Capital Federal, Buenos Aires,
1407l Argentina
Tel: +54 (11) 4672 4821
Fax:
+54 (11) 4504 4698
Cell: +54 9 (11) 4993 9996
Asia
Argus Technologies Asia Pte Ltd
Blk 6 Tagore Lane #160
Singapore 787570
Tel: +65 6458 8900
Fax:
+65 6458 2122
Australia
CPS National
8/376 Newbridge Rd
Moorebank, NSW, 2170 Australia
Tel: +61 02 9822 8977
Fax:
+61 02 9822 8077
Australia/New Zealand
Alpha Power Systems Pty Ltd
Unit 3, 30 Heathcote Road
Moorebank, NSW, 2170 Australia
Tel: +61 02 9602 8331
Fax:
+61 02 9602 9180
Century Yuasa
37 - 65 Colbalt Street
Carole Park QLD 4300
Australian Sales & Service
Tel: +61 07 3361 6587
Fax:
+61 07 3361 6705
New Zealand Sales & Service
Tel: +64 9 978 6689
Fax:
+64 9 978 6677
Canada
Compower Systems Inc.
118 Tiffield Road
Toronto, ON, M1V 5N2 Canada
Tel: +1 416 293 3088
Fax:
+1 416 293 0671
Europe
Alpha Technologies Europe Ltd.
Cartel Business Estate
Edinburgh Way
Harlow, Essex, CM20 2DU UK
Tel: +44 1279 422110
Fax:
+44 1279 423355
Mexico & Central America
Technologies Argus First De Mexico SA de CV
Anatole France No. 17
Col. Polanco
Mexico City, 11560 Mexico
Tel: +52 55 5280 6990
Fax:
+52 55 5280 6585
South America
Argus Technologies Argentina
Santo Tome 2573, Capital Federal
Buenos Aires, 1416 Argentina
Tel: +54 11 4504 4698
Cell:
+54 9 11 4993 9996
Turkey
IPC Enerji Elk San ve TIC AS
Inonu cad. Kanarya sok. No:20
Yenisahra - Kadikoy
Istanbul, Turkey
Tel: +90 216 317 41 42
Fax:
+90 216 472 90 66
048-507-10-I1 Rev S (09/2007)
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This manual contains important safety and operating
instructions for the Argus Plug-in Breaker Panel.
1. Before using the breaker panel, read all instructions and cautionary markings on the panel and
any product using the panel.
2. Do not expose the panel to rain or snow.
3. CAUTION – Unless otherwise noted, use of an attachment not recommended or sold by the
breaker panel manufacturer may result in a risk of fire, electric shock, or injury to persons.
4. CAUTION – Do not operate the panel if it has received a sharp blow, been dropped, or
otherwise damaged in any way – return it to a qualified service center for repair.
5. CAUTION – Do not disassemble the panel – call our qualified service centers for servicing.
Incorrect reassembling may result in a risk of electrical shock or fire.
ARGUS
TECHNOLOGIES 020-588-C0 R
EV
A
C2
100nF
100nF
100V
C1
P2
3
2
1
+12V
U1:A
LM2903N
1
8
4
+
3
-
2
K1 RZ48
16
1
6
4
8
11
13
9
10K0
R7
18K2
R2
15K0
R4
2W
3K6
R1
12V
D17
1N5242B
MPSA06
Q1
20K0
R11
U1:B
LM2903N
7
+
5
-
6
1994 ARGUS TECHNOLOGIES LTD.C
47K5
R8
4K75
R5
10K0
R3
1
4
5
6
7
9
10
11
13
14
15
2
3
8
12
16
1M00
R6
+12V
+48V
4
5
3
2
1
D16
1N3070
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D3
D4
D2
D1
D18
1N3070
D19
1N3070
1
2
3
B
-48 VOLTS
SHEET 2 ADDEDB
10:00:16
Fri Jan 23 2004
LIST 0, 2
94/07WES
NC
NO
D20
R9, 10
RESERVED
ALARM
94/06WES
1
94/06WES
P1
+48V POWER
- POWER
LAST USED
TB1
K1
C2
U1
Q1
FROM BREAKER OUTPUTS ( LOAD SIDE )
SCHEMATIC, PCB ASSY,
400A UDC E/W SNAP-IN BREAKERS
BREAKER ALARM
707-104-05
R11
TB1
TB1
P3
C
C
95/03 WES
NC
C
NO
ALARM
P3
D19
5
ADDED P3, SHEETS 3-5
2003/11
A
B
C
D
E
34567
12
TYPE DWG NO.
APPROVED
N/A
SIZE REV
DATE
ISSUE
SHEET OF
TITLE
TOLERANCES
CHECKED
DESIGN
DRAWN
SCALE
FINISH
MATERIAL
FOR MANUFACTURING WITHOUT ITS WRITTEN CONSENT.
THESE DESIGNS AND SPECIFICATIONS ARE THE PROPERTY OF
ARGUS TECHNOLOGIES AND SHALL NOT BE COPIED OR USED
REVISIONS
APPDLTR DESCRIPTION DATE
S1
G
LOHCNO IESET
R
C2
100nF
100nF
100V
C1
12V
D17
1N5242B
4K02
R10
P2
3
2
1
+12V
U1:A
LM2903N
1
8
4
+
3
-
2
RZ24K1
16
1
6
4
8
11
13
9
10K0
R7
18K2
R2
15K0
R4
2W
1K0
R1
MPSA06
Q1
U1:B
LM2903N
7
+
5
-
6
1994 ARGUS TECHNOLOGIES LTD.C
47K5
R8
15K0
R5
24K3
R3
1M00
R6
+24V
+12V
10K0
R9
1
4
5
6
7
9
10
11
13
14
15
2
3
8
12
16
3
2
1
4
5
D20
1N3070
D19
1N3070
D18
1N3070
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D12
D13
D14
D15
D16
1N3070
1
2
3
R10
P3
C
B
5
+24 VOLTS
+24V POWER
LIST 0, 1
2
09:59:27
Fri Jan 23 2004
NC
NO
RESERVED
ALARM
- POWER
LAST USED
TB1
K1
D20
C2
U1
Q1
FROM BREAKER OUTPUTS ( LOAD SIDE )
SCHEMATIC, PCB ASSY,
400A UDC E/W SNAP-IN BREAKERS
BREAKER ALARM
707-104-05
R11
P1
P3
NC
C
NO
ALARM
TB1
TB1
A
B
C
D
E
34567
12
TYPE DWG NO.
APPROVED
N/A
SIZE REV
DATE
ISSUE
SHEET OF
TITLE
TOLERANCES
CHECKED
DESIGN
DRAWN
SCALE
FINISH
MATERIAL
FOR MANUFACTURING WITHOUT ITS WRITTEN CONSENT.
THESE DESIGNS AND SPECIFICATIONS ARE THE PROPERTY OF
ARGUS TECHNOLOGIES AND SHALL NOT BE COPIED OR USED
REVISIONS
APPDLTR DESCRIPTION DATE
S1
G
LOHCNO IESET
R
E?
1N3070
D19
D1
D2
D4
D3
D5
D6
D7
D8
D9
D10
D11
D12
D13
D14
D15
1N3070
D16
1
2
+48V
+12V
R6
1M00
16
12
8
3
2
15
14
13
11
10
9
7
6
5
4
1
R3
10K0
R5
4K75
R8
47K5
C 1994 ARGUS TECHNOLOGIES LTD.
LM2903N
U1:B
-
6
+
5
7
R11
20K0
Q1
MPSA06
1N5242B
D17
12V
R1
3K6
2W
R4
15K0
R2
18K2
R7
10K0
LM2903N
U1:A
-
2
+
3
4
8
1
+12V
C1
100V
100nF
100nF
C2
P2
3
2
1
K1 RZ48
16
1
6
4
8
11
13
9
4
5
3
D18
1N3070
DS1
1W
4K7
R12
5
B
DS1
R12
D19
EXPANDER PCB
- POWER
+48V POWER
OUTPUT
ALARM
3
LIST 0, 2, 80, 83
ALARM
C707-104-05
BREAKER ALARM
400A UDC E/W SNAP-IN BREAKERS
SCHEMATIC, PCB ASSY,
FROM BREAKER OUTPUTS ( LOAD SIDE )
Q1
U1
C2
K1
P2
TB1
LAST USED
P1
RESERVED
R9, 10
D20
Fri Jan 23 2004
10:01:08
-48 VOLTS
NC
NO
TB1
RED
TB1
LIST 80:
LIST 83
ALARM INPUT
A
B
C
D
E
34567
12
TYPE DWG NO.
APPROVED
N/A
SIZE REV
DATE
ISSUE
SHEET OF
TITLE
TOLERANCES
CHECKED
DESIGN
DRAWN
SCALE
FINISH
MATERIAL
FOR MANUFACTURING WITHOUT ITS WRITTEN CONSENT.
THESE DESIGNS AND SPECIFICATIONS ARE THE PROPERTY OF
ARGUS TECHNOLOGIES AND SHALL NOT BE COPIED OR USED
REVISIONS
APPDLTR DESCRIPTION DATE
S1
G
LOHCNO IESET
R
+24V
R12
4K7
1W
DS1
1N3070
D18
5
4
3
K1 RZ24
9
13
11
8
4
6
1
16
P2
1
2
3
C2
100nF
100nF
100V
C1
12V
D17
1N5242B
4K02
R10
+12V
U1:A
LM2903N
1
8
4
+
3
-
2
10K0
R7
18K2
R2
15K0
R4
2W
1K0
R1
MPSA06
Q1
U1:B
LM2903N
7
+
5
-
6
1994 ARGUS TECHNOLOGIES LTD.C
47K5
R8
15K0
R5
24K3
R3
1M00
R6
+12V
1
4
5
6
7
9
10
11
13
14
15
2
3
8
12
16
2
1
D19
1N3070
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D12
D13
D14
D15
D16
1N3070
B
5
D20
R9, 11
DS1
R12
D19
EXPANDER PCB
ALARM
NO
NC
+24 VOLTS
+24V POWER
10:01:57
Fri Jan 23 2004
RESERVED
- POWER
LAST USED
TB1
P2
K1
C2
U1
Q1
FROM BREAKER OUTPUTS ( LOAD SIDE )
SCHEMATIC, PCB ASSY,
400A UDC E/W SNAP-IN BREAKERS
BREAKER ALARM
707-104-05
P1
C
LIST 0, 1, 80, 83
RED
ALARM
TB1
TB1
4
LIST 80:
ALARM INPUT
LIST 83
A
B
C
D
E
34567
12
TYPE DWG NO.
APPROVED
N/A
SIZE REV
DATE
ISSUE
SHEET OF
TITLE
TOLERANCES
CHECKED
DESIGN
DRAWN
SCALE
FINISH
MATERIAL
FOR MANUFACTURING WITHOUT ITS WRITTEN CONSENT.
THESE DESIGNS AND SPECIFICATIONS ARE THE PROPERTY OF
ARGUS TECHNOLOGIES AND SHALL NOT BE COPIED OR USED
REVISIONS
APPDLTR DESCRIPTION DATE
S1
G
LOHCNO IESET
R
1N3070
D16
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
0R
R1
16
12
8
3
2
15
14
13
11
10
9
7
6
5
4
1
0R
R10
1
2
R2
0R
R3
0R
0R
R1
1N3070
D16
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
16
12
8
3
2
15
14
13
11
10
9
7
6
5
4
1
0R
R10
1
2
R2
0R
R3
0R
1994 ARGUS TECHNOLOGIES LTD.C
1
1N3070
D20
1N3070
D18
5
4
2
3
R9
0R
K1
9
13
11
8
4
6
1
16
P2
1
2
3
55
LIST 0, 82 (POS. GND)
LIST 0, 81 (NEG. GND)
ALARM
-
+
LIST 0, 84 AND LIST 0, 85
TB1
P1
FROM BREAKER OUTPUTS ( LOAD SIDE )
EXPANDER PCB
EXPANDER PCB
ALARM INPUT
ALARM OUTPUT
TB1
P1
FROM BREAKER OUTPUTS ( LOAD SIDE )
EXPANDER PCB
EXPANDER PCB
ALARM INPUT
ALARM OUTPUT
10:02:46
Fri Jan 23 2004
SCHEMATIC, PCB ASSY,
400A UDC E/W SNAP-IN BREAKERS
BREAKER ALARM
707-104-05 C
TB1
RZ24 OR RZ48
W1
NO
NC
B
A
B
C
D
E
34567
12
TYPE DWG NO.
APPROVED
N/A
SIZE REV
DATE
ISSUE
SHEET OF
TITLE
TOLERANCES
CHECKED
DESIGN
DRAWN
SCALE
FINISH
MATERIAL
FOR MANUFACTURING WITHOUT ITS WRITTEN CONSENT.
THESE DESIGNS AND SPECIFICATIONS ARE THE PROPERTY OF
ARGUS TECHNOLOGIES AND SHALL NOT BE COPIED OR USED
REVISIONS
APPDLTR DESCRIPTION DATE
S1
G
LOHCNO IESET
R
This page intentionally left blank.
Technical Support
Technical support staff are available for answering general questions related to installation, operation
and maintenance of Argus products. In Canada and the USA, call Argus toll free 7:30 am to 5:00 pm
Pacific Standard Time at:
+1-888 GO ARGUS
(+1-888-462-7487)
For emergencies, call +1-888-GO-ARGUS 24 hours a day, seven days a week.
Customers outside Canada and the USA, call +1-604-436-5547 for technical support.
Training
Argus offers various levels of product and technical training. These workshops provide a mix of
theory and hands on application for qualified customers. Please consult your sales representative for
course schedules, locations and costs, or visit our website at www.argusdcpower.com.
Factory Repair and Servicing
All service, beyond initial adjustments, should be carried out by qualified factory service personnel.
For these procedures, please contact Argus Technologies at the locations listed to the right.
Product Returns
Before returning any product for service, please obtain a Return Material Authorization (RMA) number
from an Argus factory service representative. The representative will require the model and serial
number, as well as a brief description of the problem prior to issuing the RMA number. All material
must be pre-authorized before being returned.
See document 048-507-10 “Warranty and Repair Information” for more details.
Moving and Storage
Units must be suitably packed in the original shipping container (or equivalent) prior to re-shipping.
The box should be completely enclosed and constructed of wood or double-wall, corrugated
cardboard. At least 3” of foam or shock absorbing packing material must surround the unit.
FACTORY SERVICE INFORMATION
048-527-10-I1 Rev L (09/2007)
Canada and USA toll free 24 hour emergency technical support:
+
1 888 GO ARGUS (462 7487) Outside North America: +1 604 436 5547
Factory Service Centers
Canada and International
Argus Technologies Ltd.
ATTN: RMA Returns
7033 Antrim Avenue
Burnaby, BC, V5J 4M5 Canada
Tel: +1 604 436 5900
Fax:
+1 604 436 1233
Email: returns@argusdcpower.com
USA
Argus Technologies Inc.
ATTN: RMA Returns
3116 Mercer Avenue
Bellingham, WA, 98225 USA
Tel: +1-360 756 4904
Fax:
+1-360 647 0498
Email: returns-usa@argusdcpower.com
Asia-Pacific
PCM Electronics (Dong Guan) Co., Ltd.
Hongli Industrial Area, Miaobian, Liaobu Town,
Dongguan City, Guangdong Province,
523400 China
Tel: +86 755 8895 3310
Fax:
+86 755 8895 3307
Authorized Service Center
Argentina
Argus Technologies de Argentina
Belen 315, Capital Federal, Buenos Aires,
1407l Argentina
Tel: +54 (11) 4672 4821
Fax:
+54 (11) 4504 4698
Cell: +54 9 (11) 4993 9996
Asia
Argus Technologies Asia Pte Ltd
Blk 6 Tagore Lane #160
Singapore 787570
Tel: +65 6458 8900
Fax:
+65 6458 2122
Australia
CPS National
8/376 Newbridge Rd
Moorebank, NSW, 2170 Australia
Tel: +61 02 9822 8977
Fax:
+61 02 9822 8077
Australia/New Zealand
Alpha Power Systems Pty Ltd
Unit 3, 30 Heathcote Road
Moorebank, NSW, 2170 Australia
Tel: +61 02 9602 8331
Fax:
+61 02 9602 9180
Century Yuasa
37 - 65 Colbalt Street
Carole Park QLD 4300
Australian Sales & Service
Tel: +61 07 3361 6587
Fax:
+61 07 3361 6705
New Zealand Sales & Service
Tel: +64 9 978 6689
Fax:
+64 9 978 6677
Canada
Compower Systems Inc.
118 Tiffield Road
Toronto, ON, M1V 5N2 Canada
Tel: +1 416 293 3088
Fax:
+1 416 293 0671
Europe
Alpha Technologies Europe Ltd.
Cartel Business Estate
Edinburgh Way
Harlow, Essex, CM20 2DU UK
Tel: +44 1279 422110
Fax:
+44 1279 423355
Mexico & Central America
Technologies Argus First De Mexico SA de CV
Anatole France No. 17
Col. Polanco
Mexico City, 11560 Mexico
Tel: +52 55 5280 6990
Fax:
+52 55 5280 6585
South America
Argus Technologies Argentina
Santo Tome 2573, Capital Federal
Buenos Aires, 1416 Argentina
Tel: +54 11 4504 4698
Cell:
+54 9 11 4993 9996
Turkey
IPC Enerji Elk San ve TIC AS
Inonu cad. Kanarya sok. No:20
Yenisahra - Kadikoy
Istanbul, Turkey
Tel: +90 216 317 41 42
Fax:
+90 216 472 90 66
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Alpha Breaker Panels Owner's manual

Type
Owner's manual

Alpha Breaker Panels are a line of high-quality, feature-rich breaker panels that are perfect for a variety of residential and commercial applications. These panels are designed to provide reliable power distribution and protection, and they come with a variety of features that make them easy to install and use.

Some of the key features of Alpha Breaker Panels include:

  • Front access: All breakers are accessible from the front of the panel, making it easy to reset or replace breakers without having to remove the panel from the wall.
  • Plug-in breakers: The breakers are plug-in, which makes them easy to install and replace.

Ask a question and I''ll find the answer in the document