Alcatel-Lucent 7210 SAS-T Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Alcatel-Lucent 7210 SAS-T Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
7210 SAS-T
I
NSTALLATION GUIDE
August 2013
Document Part Number: 93-0475-01-01
*93-0475-01-01*
Copyright 2013 Alcatel-Lucent All rights reserved.
No portion of this document may be reproduced in any form or means without prior written permission from Alcatel-Lucent.
Information in this document is proprietary and confidential to Alcatel. The information in this document is subject to change. All
trademarks and registered trademarks are the property of the respective owners.
USA Requirements Only
Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the interference at his own expense.
Canadian Requirements Only
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Réglement sur le matériel brouilleur du Canada.
Japan/Nippon Requirements Only
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to
take adequate measures.
Caution:
Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser
radiation exposure.
VCCI-A
7210 SAS-T Installation Guide Page 3
Preface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
7210 SAS-T Overview
7210 SAS-T Introduction and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Switch Architecture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Network Management Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Hardware Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Ethernet Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Management Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Alarm Interface Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Power Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
DC power source failure detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
USB Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Compact Flash Memory Card Slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
System LEDs and Buttons. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
System and Port LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Port LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
System Buttons and Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Installing the 7210 SAS-T
Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Selecting a Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Ethernet Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Equipment Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Installing Your Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
R
ack Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Desktop or Shelf Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Grounding the Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Connecting to a Power Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Connecting to AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Connecting to DC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Connecting to the Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Warnings and Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Installation Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Locking Mechanisms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Installing SFP/XFPs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Removing SFP/XFPs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Configuring the 7210 SAS-T
Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Post Installation Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
TABLE OF CONTENTS
Page 4 7210 SAS-T Installation Guide
Table of Contents
Initializing the System and Downloading Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Booting a 7210 SAS-T in the Lab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Booting a 7210 SAS-T from the USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Booting a 7210 SAS-T from the External Compact Flash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Booting a 7210 SAS-T using the image on Flash (with the image shipped by factory) . . . . . . . . . 57
Booting a 7210 SAS-T From the Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Using the Out-of-Band Ethernet Management port to boot 7210 from the nework: . . . . . . . . . . . . 65
Downloading the TiMOS Software to the Internal Flash. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Establishing Router Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Console Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Telnet Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Running Telnet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Troubleshooting
Diagnosing Switch Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Power and Cooling Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
In-Band Access. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Appendix A: Specifications
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Japan VCCI Class A Declaration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
RoHS and WEEE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Appendix B: Pin Assignments
Management Port Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Console Port Pin Assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Appendix C: Alarm Pin Assignments
Alarm Port Pin Assignments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
7210 SAS-T Installation Guide Page 5
LIST OF TABLES
Preface
Table 1: Information Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
7210 SAS-T Overview
Table 2: 7210 SAS-T (Non-ETR Variant) Front Panel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Table 3: 7210 SAS-T (ETR Variant) Front Panel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Table 4: Alarm Interface Port Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Table 5: Power Module LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Table 6: Power Source Failure Detection Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Table 7: 7210 SAS-T System LEDs and Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Table 8:
System and Port Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Table 9: Port LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Table 10: Port LED Key Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Table 11: Front Panel Buttons and Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Installing the 7210 SAS-T
Table 12: Serial Cable Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Configuring the 7210 SAS-T
Table 1: Console Configuration Parameter Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
Troubleshooting
Table 2: Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
Appendix A: Specifications
Table 3: 7210 SAS-T Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80
Appendix B: Pin Assignments
Table 4: 10/100BASE-TX MDI and MDI-X Port Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84
Table 5:
Serial Cable Wiri ng . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Appendix C: Alarm Pin Assignments
Table 6: Alarm Interface Port Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89
Page 6 7750 SR-12
List of Tables
7210 SAS-T Installation Guide Page 7
LIST OF FIGURES
7210 SAS-T Overview
Figure 1: 7210 SAS-T (Non-ETR Variant) Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Figure 2: 7210 SAS-T (ETR Variant) Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Figure 3:
7210 SAS-T (Non-ETR Variant) Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Figure 4:
7210 SAS-T (ETR Variant) Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Figure 5:
AC and DC Power Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Figure 6:
Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Figure 7: Loosening Captive Screws on the Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Figure 8: Removing the Fan Tray. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Figure 9: Replacing the Fan Tray. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Figure 10: Tightening Captive Screws on the Fan Tray. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Figure 11:
System LEDs and Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Figure 12:
SFP Port LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Installing the 7210 SAS-T
Figure 13: Attaching the Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Figure 14:
Installing the Switch in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Figure 15:
Attaching the Adhesive Feet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Figure 16: Connecting to a -48 VDC Power Source. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Figure 17: Connecting to a +24 VDC Power Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Configuring the 7210 SAS-T
Figure 1: 7210 SAS-T Boot Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
Troubleshooting
Appendix A: Specifications
Appendix B: Pin Assignments
Appendix C: Alarm Pin Assignments
Figure 2: DB-15 Alarm Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
Figure 3: Example for Alarm Inputs Using an External Power Source. . . . . . . . . . . . . . . . . . . . . . . . . . . .91
Figure 4: Example for Alarm Inputs Using an External Power Source. . . . . . . . . . . . . . . . . . . . . . . . . . . .92
Page 8 7210 SAS-T Installation Guide
List of Figures
7210 SAS-T Installation Guide Page 1
Preface
About This Manual
This guide provides site preparation recommendations, step-by-step procedures to rack mount the
Alcatel-Lucent 7210 SAS-T
®
and instructions to install and configure the TiMOS software.
Each 7210 SAS-T router is shipped with rack-mounting brackets, a console cable, power cord (AC
only), and rubber feet.
Warnings and Notes
Observe the warnings and notes to avoid injury or router damage during installation and
maintenance. Follow the safety procedures and guidelines when working with and near electrical
equipment. Warning statements and notes are provided in each chapter.
Audience
This guide is intended for network installers and system administrators who are responsible for
installing, configuring, or maintaining networks. This guide assumes you are familiar with
electronic and networking technologies.
Page 2 7210 SAS-T Installation Guide
Information Symbols
Table 1 describes symbols contained in this guide.
Technical Support
If you purchased a service agreement for your 7210 SAS-T and related products from a distributor
or authorized reseller, contact the technical support staff for that distributor or reseller for
assistance. If you purchased an Alcatel-Lucent service agreement, contact technical assistance at:
http://www.alcatel-lucent.com/wps/portal/support
Table 1: Information Symbols
Symbol Meaning Description
Danger This symbol warns that improper handling and installation could result in bodily
injury. An electric shock hazard could exist. Before you begin work on this
equipment, be aware of hazards involving electrical circuitry, networking
environments, and instigate accident prevention procedures.
Caution This symbol warns that improper handling and installation could result in
equipment damage or loss of data.
Warning This symbol warns that improper handling may reduce your component or
system performance.
Note This symbol provides additional operational information.
Class 1 laser products are listed in the MDA installation guides. Only approved
Class 1 replaceable laser transceivers should be used with this product.
Class 1 Laser Product
7210 SAS-T Installation Guide Page 3
7210 SAS-T Overview
This chapter describes the 7210 SAS-T features and includes the following sections:
7210 SAS-T Introduction and Features on page 4
Switch Architecture on page 6
Features on page 7
Hardware Description on page 9
7210 SAS-T Introduction and Features
Page 4 7210 SAS-T Installation Guide
7210 SAS-T Introduction and Features
The 7210 SAS-T is a Layer-2 service-aware Ethernet-capable switch. The switch is available as
two variants, as follows:
7210 SAS-T (Non-ETR variant) with support for up to 12 100/1000 fiber-optic SFP ports,
10 10/100/1000 Copper SFP ports and 4 XFP-based 10 Gig ports
7210 SAS-T (ETR) with support for up to 12 100/1000 fiber-optic SFP ports, 6 10/100/
1000 Copper SFP ports, 4 XFP based 10 Gig ports and 4 Power over Ethernet (PoE) ports
Figure 1: 7210 SAS-T (Non-ETR Variant) Front Panel
The 7210 SAS-T (Non-ETR variant) includes the following features:
12 100/1000 fiber-optic SFP ports
10 10/100/1000 Base-T fixed Copper ports
Four XFP-based 10 Gig ports
Option to use redundant power supplies
One single fan tray with 3 fans and a fan filter
One RJ-45 management port for firmware upgrade or system management
One RJ-45 console (RS-232 interface) connector for device management
One DB15 connector alarm port
Two BITS ports (reserved for future use)
Two timing output jacks (1 PPS, 10 MHz) (reserved for future use)
One USB port and One external removable CF memory card slot (cf2:\)
One OMC (Optical Management Console) port
One reset button
Embedded SR OS
Compact size: 1.5RU height, 19-inch rack-mountable metal enclosure, 10-inch depth (ETSI)
Crit
Maj
Fan
Status
PS1
PS2
USB
Alarm
+24V +12V
+24V
DC PEM
200W
+24V +12V
+24V
DC PEM
200W
CF2
OMC
23 24 25 26
Management
Fan
1PPS
BITS2/ToD2
BITS1/ToD1
10MHz
ACO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
–A
+A
–B
+B
SAS_T_005
Reset
7210 SAS-T Overview
7210 SAS-T Installation Guide Page 5
Figure 2: 7210 SAS-T (ETR Variant) Front Panel
The 7210 SAS-T (ETR variant) include the following features:
12 100/1000 fiber-optic SFP ports
10 10/100/1000 Base-T fixed Copper ports
Four PoE Copper ports (out of the total 10 copper port)
Four XFP-based 10 Gig ports
Option to use redundant power supplies
One single fan tray with 3 fans and a fan filter
One RJ-45 management port for firmware upgrade or system management
One RJ-45 console (RS-232 interface) connector for device management
One DB15 connector alarm port
Two BITS ports(reserved for future use)
Two timing output jacks (1 PPS, 10 MHz) (reserved for future use)
One USB port and One external removable CF memory card slot (cf2:\)
One OMC (Optical Management Console) port
One reset button
•Embedded SR OS
Compact size: 1.5RU height, 19-inch rack-mountable metal enclosure, 10-inch depth (ETSI)
Crit
Maj
Fan
Status
PS1
PS2
USB
Alarm
+24V +12V
+24V ETR
DC PEM
200W
+24V +12V
+24V ETR
DC PEM
200W
CF2
OMC
23 24 25 26
Management
POE
Fan
1PPS
BITS2/ToD2
BITS1/ToD1
10MHz
ACO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
–A
+A
–B
+B
SAS_T_002
Reset
Note: The OMC port, the BITS ports, the 1PPS interface and the 10MHz are reserved for
future use and is not currently supported.
Switch Architecture
Page 6 7210 SAS-T Installation Guide
Switch Architecture
The 7210 SAS-T employs a wire-speed, non-blocking switching fabric. This permits simultaneous
wire-speed transport of multiple packets at low latency on all ports.
Network Management Options
This switch contains a comprehensive array of LEDs for at-a-glance monitoring of network and
port status. It also includes a management agent that enables you to configure or monitor your
switch using its CLI, or by using SNMP applications.
To manage the switch, you can make a direct connection to the console port (out-of-band Ethernet
management port) or you can manage it by using a network connection (in-band SFP or XFP
ports) using Telnet/SSH or SNMP-based network management software (such as ALU 5620
SAM).
The management port provides a dedicated management channel that operates outside of the data
transport network. This makes it possible to reconfigure or troubleshoot the switch over either a
local or remote connection to the management port when access using the data channel is not
possible or deemed insecure.
7210 SAS-T Overview
7210 SAS-T Installation Guide Page 7
Features
The 7210 SAS-T includes the following features:
All connections front facing
Wire speed, non-blocking, service-aware layer-2 switch
12 100/1000 fiber-optic SFP ports
10 10/100/1000 Base-T fixed Copper ports
Four PoE Copper SFP ports (out of the 10 Copper ports)
Four XFP-based 10 Gig ports
•Powered by SR OS
Per-service quality of service (QoS) with up to eight levels of class-based queuing per port
Per-service OAM toolkit with IEEE 802.1ag, IEEE 802.3ah and local service mirroring
Supports NULL, Dot1Q access and QinQ SAPs.
Dual-homed connections uplinks to separate aggregation devices
Flexible deployment options with support for mesh and ring topologies
MEF 9 and MEF 14 compliant platform
Managed by the 5620 SAM
Provides four isolated alarm inputs and two dry contacts that relay outputs through a
DB-15 interface on the front panel. Option to supply power to the devices connected to
alarm inputs.
Hot-swappable, redundant, load sharing AC or DC power and fan modules
Front-removable fan tray with removable air filter
7210 SAS-T (non-ETR variant): power ~ 130W
7120 SAS-T (ETR variant): power ~ 200W (includes 60W for four optional PoE ports)
DC input connection screw terminal based
1.5U rack mountable or desktop, depth target 255 mm
Multi-core CPU with 1GB RAM
Compact Flash-based field replaceable flash memory
USB port for using USB storage sticks/devices.
OMC (Optical Management Console) port to connect up to 4 1830 VWM devices.
Front panel accessible reset button
DC Input power detection
Features
Page 8 7210 SAS-T Installation Guide
Temperature monitoring functions
Console and management ports
Sync E & 1588 support
7210 SAS-T has an operating range of 0 Celsius to 40 Celsius
7210 SAS-T ETR variant has an environmental rating of -40 to +65 degree C operation
Connectivity
The 7210 SAS-T includes the following connectivity features:
10/100/1000 Base-T fixed Copper ports
100/1000 fiber-optic SFP ports
10G XFP ports
IEEE 802.3-2005 Ethernet, Fast Ethernet, Gigabit Ethernet, and Ten-Gigabit compliance
ensures compatibility with standards-based network cards and switches from any vendor.
7210 SAS-T Overview
7210 SAS-T Installation Guide Page 9
Hardware Description
Figure 3: 7210 SAS-T (Non-ETR Variant) Front Panel
Crit
Maj
Fan
Status
PS1
PS2
USB
Alarm
–48V +12V
DC
PEM
200W
–48V +12V
DC
PEM
200W
CF2
OMC
23 24 25 26
Management
Fan
1PPS
BITS2/ToD2
BITS1/ToD1
10MHz
ACO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
–A
+A
–B
+B
SAS_T_012
135 8 14 11 1217
21 4
9 16
Reset
3
6
7
10
15
Table 2: 7210 SAS-T (Non-ETR Variant) Front Panel Features
Key Description
1 Ground and DC power connection
2 Power trays
3 LEDs
4 Alarm connector
5USB port
6 Alarm cut off button
7 Reset button
8 External Compact Flash memory card slot (cf2:\)
9 100/1000 fiber-optic SFP ports
10 Management port
11 Console port
12 Fan tray
Hardware Description
Page 10 7210 SAS-T Installation Guide
Figure 4: 7210 SAS-T (ETR Variant) Front Panel
13 BITS timing ports (reserved for future use)
14 OMC (Optical Management Console) port
(reserved for future use)
15 1PPS timing output and 10 Mhz timing output
(reserved for future use)
16 10/100/1000 Base-T fixed Copper ports
17 10Gig XFP ports
Table 2: 7210 SAS-T (Non-ETR Variant) Front Panel Features
Key Description
Crit
Maj
Fan
Status
PS1
PS2
USB
Alarm
–48V +12V
DC ETR
PEM
200W
–48V +12V
DC ETR
PEM
200W
CF2
OMC
23 24 25 26
Management
POE
Fan
1PPS
BITS2/ToD2
BITS1/ToD1
10MHz
ACO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
–A
+A
–B
+B
SAS_T_009
135 8 14 11 1217
21 4
9 16
Reset
3
6
7
10
15
18
Table 3: 7210 SAS-T (ETR Variant) Front Panel Features
Key Description
1 Ground and DC power connection
2 Power trays
3 LEDs
4 Alarm connector
7210 SAS-T Overview
7210 SAS-T Installation Guide Page 11
5USB port
6 Alarm cut off button
7 Reset button
8 External Compact Flash memory card slot (cf2:\)
9 100/1000 fiber-optic SFP ports
10 Management port
11 Console port
12 Fan tray
13 BITS timing ports (reserved for future use)
14 OMC (Optical Management Console) port
(reserved for future use)
15 1PPS timing output and 10 Mhz timing output
(reserved for future use)
16 10/100/1000 Base-T fixed Copper ports
17 10Gig XFP ports
18 PoE power ports
Table 3: 7210 SAS-T (ETR Variant) Front Panel Features
Key Description
Hardware Description
Page 12 7210 SAS-T Installation Guide
Ethernet Interfaces
The 7210 SAS-T provides 12 100/1000 fiber-optic SFP ports. Each port can be used for a direct
connection to a subscribers Customer Premises Equipment (CPE), or as an uplink to another
aggregation node. The 7210 SAS-T supports 10/100/1000 Base-T copper SFPs. The 7210 SAS-T
also provides ten 10/100/1000 Base-T fixed Copper ports. There are four XFP ports, which support
10G redundant network uplinks to another aggregation node or provide 10G redundant
connectivity to a subscriber's CPE. In addition, the 7210 SAS-T ETR variant supports four power-
over-Ethernet (PoE) ports.
Management Port
The management port provides a dedicated management interface that is segregated from data
traffic crossing the other ports.
/