  • Hello! I am an AI chatbot trained to assist you with the Lenovo ThinkServer RD630 Installation Instructions Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
RackInstallationInstructions
Guidelines
Thispublicationprovidesinformationabouthowtoinstallyourserverintoastandardrackcabinetusingthe
railkitshippedwithyourserver.
Ifyounolongerhaveacopyofthispublication,youcanobtainaPortableDocumentFormat(PDF)version
fromtheLenovo
®
SupportWebsiteat:
http://www.lenovo.com/ThinkServerUserGuides
CAUTION:
Besuretoreadandunderstandthedocumentationthatcomeswiththerackcabinetforsafetyand
cablinginformation.Alsomakesurethatyoureadandunderstandalltherelatedsafetyinformation
fortheserverandreviewtheguidelinesinthispublicationbeforeyouinstalltheserverintoarack
cabinet.Readingandunderstandingtheinformationreducestheriskofpersonalinjuryandor
damagetoyourproduct.
Therackcabinetmustmeetoneofthefollowingrequirements:
Standard4-post(square-hole),19-inchrackcongurationcompliantwithEIA-310-Easdenedbythe
ElectronicIndustriesAlliance
Standard4-post(unthreadedround-hole),19-inchrackcongurationcompliantwithEIA-310-Easdened
bytheElectronicIndustriesAlliance
1
Thedimensionsoftherackcabinetmustmeetthefollowingrequirements:
Figure1.Thedimensionrequirementsoftherackcabinet
1Rearmountingange
2Frontmountingange
3Frontdooroftherackcabinet
Thefollowingtableexplainsthedimensionrequirementsoftherackcabinet.
Table1.Thedimensionrequirementsoftherackcabinet
ItemDimensionsDescription
A
750mm900mm29.53
35.43inches
ItemAreferstothedistancebetweenthefrontmountingange2andthe
rearmountingange
1.Thedistanceshouldbe750mm(29.53inches)in
minimumand900mm(35.43inches)inmaximum.
B
>474mm(18.66inches)
ItemBreferstothewidthoftheserverincludingtherailkitwhentheserver
isinstalledintotherackcabinet.Thewidthshouldexceed474mm(18.66
inches).
D
>60mm(2.36inches)
ItemDreferstothedistancebetweenthefrontmountingange
2andthe
insideofthefrontdooroftherackcabinet3.Thedistanceshouldexceed
60mm(2.36inches).Thisclearanceisrequiredforthechassispullhandles
onthefrontoftheserveraswellasaircirculationthroughthecabinet.
L
>950mm(37.4inches)
ItemLreferstothedistancebetweenthefrontmountingange
2andthe
rearoftheserver.Thedistanceshouldexceed950mm(37.4inches).This
clearanceisusedtosaveadequatespaceforthecablemanagementarm.
Beforeyouinstalltheserverintoarackcabinet,reviewthefollowingguidelinestohelpyouinyourinstallation
andavoidtheriskofpersonalinjuryandordamagetoyourproduct:
Twoormorepeoplearerequiredtoliftaserver,moveaserver,orinstallaserverintoarackcabinet
iftheservermeetsoneofthefollowingcriteria:
2
Theserveris2Uorlarger.(“U”istheunitofmeasurementfordeningtheverticalspaceusedbyyour
serverand1Uisequivalentto4.445cmor1.75inches.)
Theweightoftheserverisratedabove18kg(39.7lbs).Refertothefollowingstatementforsafe
practiceswhenlifting.
18kg(39.7lb)32kg(70.5lb)55kg(121.2lb)
<32kg(70.5lb)<55kg(121.2lb)<100kg(220.5lb)
CAUTION:
Usesafepracticeswhenlifting.
Beforeinstallingaserverintoarackcabinet,removeallmediafromthedrivesandturnoffallattached
devicesandtheserver.Then,disconnectallpowercordsfromelectricaloutletsanddisconnectall
cablesthatareconnectedtotheserver.
Makesurethattheroomairtemperatureisbelow35°C(95°F).
Donotblockanyairvents;usually15cm(6inches)ofspaceprovidesproperairow.
Donotleaveopenspacesaboveorbelowaninstalledserverinyourrackcabinet.Tohelpprevent
damagetoservercomponents,alwaysinstallablankllerpaneltocovertheopenspaceandtohelp
ensureproperaircirculation.
Installtheserveronlyinarackcabinetwithperforateddoor(s)forbothsecurityandproperairow.
Startfromthebottomoftherackcabinetfortheserverordeviceinstallation.
Installtheheaviestserverordeviceinthebottomoftherackcabinet.
Donotextendmorethanoneserverordeviceoutoftherackcabinetatthesametime.
Ifpossible,removethedoorsandsidepanelsoftherackcabinettoprovideeasieraccessduring
installation.
Donotoverloadtheelectricaloutletwhenyouinstallmultipledevicesintherackcabinet.
Connectallpowercordstoproperelectricaloutletsandrefertothedocumentationthatcomeswiththe
rackcabinetforcablinginformationtohelpyouproperlymanageallthecablesintherackcabinet.
Observethefollowingguideline:
CAUTION:
Donotplaceanyobjectontopofrack-mounteddevices.
3
Railkitpackage
Beforeyoubegintherackinstallation,removeallthepartsfromtherailkitpackageshippedwithyour
serverandlayallthepartsonaworkingsurface.
Notes:
Anoptionalcablemanagementarmcanhelpyoutomanageyourcables.ContactyourlocalService
Providertopurchasethecablemanagementarmandrefertothelaterpartofthissectionformore
informationaboutthecablemanagementarm.
Allthepartsrelatedtothecablemanagementarminthefollowingguresaremadeingrey.Thisindicates
thattheyareoptional.
Therailkitpackagecontainsthefollowingparts.Contactyourplaceofpurchaseifanypartismissingor
damaged.
Figure2.Partsintherailkitpackage
1Sliderails(2)5M6x16screws(2)
2Bar-railjoint
6Cablemanagementarm
3Cablemanager
7Arm-railjoint
4#10-32x10screws(2)8Crossbar
4
Theleftsliderailandtherightsliderailarealmostthesame.Theillustrationbelowshowsthecomponentsof
theleftsliderail.
Figure3.Sliderailcomponents
1Frontendofthesliderail3Rearendofthesliderail
2Innerrail
4Outerrail
Note:TheinnersideoftheleftsliderailismarkedwithL.TheletterLstandsforleft.Theinnersideofthe
rightsliderailismarkedwithR.TheletterRstandsforright.
Theillustrationbelowshowsthecomponentsofthecablemanagementarm.
Figure4.Cablemanagementarmcomponents
1ArmmarkedwithA2ArmmarkedwithB
5
Installingyourserverintoarackcabinetusingtherailkit
Beforeyoubegin,removeallthepartsfromtherailkitpackageandlayallthepartsonaworkingsurface.
See“Railkitpackage”onpage4.Thelengthofeachsliderailrangesfrom65cm(25.6inches)when
collapsedto90cm(35.4inches)whenfullyextended.Measuretherackbeforetheinstallationtoensurethat
therackcanaccommodatethesliderail.
Attention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstandingthe“Guidelines”
onpage1.
Toinstalltheserverintoarackcabinetusingtherailkit,dothefollowing:
1.Installtherailkitbydoingthefollowing:
a.Onarearmountingangeoftherightsideoftherackcabinet,selectaproperrackmountingarea
fortherightsliderail.Positiontherearendoftherightsliderailtothemountingareasothatthe
tabsontherearendoftherightsliderailarealignedwiththecorrespondingholesinthemounting
area.Pushtherightsliderailinthedirectionasshowninthegureuntiltherearendoftheright
sliderailisrmlysecuredtothemountingange.
Note:Theholesinamountingangeareseparatedintogroupsbymeasuringmarks.Thethree
holesbetweentwoadjacentmeasuringmarksformagroup,whichindicates1Uspace.Notethe
measuringmarksonamountingangetohelpyoucorrectlyselectarackmountingareaforthe
server.Formoreinformationabouttheplacementoftheholesinamountingange,refertothe
documentationthatcomeswiththerackcabinet.
Figure5.Securingtherearendoftherightsliderailtothemountingange
6
b.Pullupthereleaselatch1onthefrontendoftherightsliderail.Keepthereleaselatchinthe
raisedpositionandpullouttheslideraillock2.
Figure6.Unlockingtheslideraillock
c.Positionthefrontpartoftherightsliderailtothemountingange.Makesurethatthefrontendand
rearendoftherightsliderailareatthesamehorizontallevel.Pushtherightsliderail1untilthe
frontendoftherightsliderailisrmlysecuredtothemountingange.Pushtheslideraillock2
backhorizontallyuntilitislockedintoplace.
Figure7.Securingthefrontendoftherightsliderailtothemountingange
7
d.Repeatsteps1through3toinstalltheleftsliderailtotheoppositesideoftherackcabinet.
2.Installthecablemanagementarmbydoingthefollowing:
a.Turntotherearoftherackcabinet.
b.Alignthebumponthecrossbarwiththedentonthebar-railjoint1.Turnthecrossbarcounter
clockwiseuntilitissecured2.
Figure8.Connectingthecrossbarandthebar-railjoint
c.Alignthebumpontheotherendofthecrossbarwiththedentonthesliderail1.Turnthecrossbar
counterclockwise2untilitissecured.Pullouttheejectbutton3andinsertthebar-railjoint
intothesliderail4.
Figure9.Connectingthecrossbarandthesliderails
8
d.ConnectthearmmarkedwithAandthearm-railjointbypullingouttheejectbutton1andinserting
thearmintothearm-railjoint2.
Figure10.Connectingthecablemanagementarmandthearm-railjoint
e.ConnectthearmmarkedwithBandthesliderailbypullingouttheejectbutton1andinsertingthe
armintothearm-railjoint2.ThenconnectthearmmarkedwithAandthesliderailbypullingout
theejectbutton3andinsertingthearmintothearm-railjoint4.
Figure11.Connectingthecablemanagementarmandthesliderail
9
3.Installtheserverbydoingthefollowing:
a.Fullyextendtheinnerrailsonbothsidesuntiltheinnerrailscannotbepulledoutfurther.
Figure12.Fullyextendingtheinnerrails
10
b.Positiontheserverasshowninthefollowingillustration.Mountandsecurethepairofrailmount
pointsattherear1rst.Thenmountandsecurethepairofrailmountpoints2.Finally,holdand
pressthesliderailstowardstheserveruntiltherailmountpoints3arelockedintoplace.
Figure13.Securingtheserver
11
Thefollowingillustrationshowswhattherailmountpoints3looklikewhenlockedintoplace.
Figure14.Therailmountpointsarelockedintoplace
12
4.Liftthelatch1onbothsidestoreleasetheinnerrails.Gentlyslidetheinnerrailswiththeserver
intotherackcabinet2.
CAUTION:
Toavoidinjurytongers,keephandsfreefromthelatchareawhenthelatchapproachesthe
outerrail.
Figure15.Slidingtheinnerrailswiththeserverintotherackcabinet
13
5.SecuretheservertotherackcabinetwithanM6x16screwonbothsidesofthefrontoftheserver.
Figure16.Securingtheservertotherackcabinet
Trademarks
LenovoandtheLenovologoaretrademarksofLenovointheUnitedStates,othercountries,orboth.
Othercompany,product,orservicenamesmaybetrademarksorservicemarksofothers.
14
SecondEdition
©CopyrightLenovo2012.
LIMITEDANDRESTRICTEDRIGHTSNOTICE:IfdataorsoftwareisdeliveredpursuantaGeneralServicesAdministration
“GSAcontract,use,reproduction,ordisclosureissubjecttorestrictionssetforthinContractNo.GS-35F-05925.
PrintedinChina
(1P)P/N:0A91994
*1P0A91994*
(May2012)
/