Lenovo ThinkServer RD330 Installation Instructions Manual

Type
Installation Instructions Manual

This manual is also suitable for

RackInstallationInstructions
Guidelines
Thispublicationprovidesinformationabouthowtoinstallyourserverintoastandardrackcabinetusingthe
railkitshippedwithyourserver.
Ifyounolongerhaveacopyofthispublication,youcanobtainaPortableDocumentFormat(PDF)version
fromtheLenovo
®
SupportWebsiteat:
http://www.lenovo.com/ThinkServerUserGuides
CAUTION:
Besuretoreadandunderstandthedocumentationthatcomeswiththerackcabinetforsafetyand
cablinginformation.Alsomakesurethatyoureadandunderstandalltherelatedsafetyinformation
fortheserverandreviewtheguidelinesinthispublicationbeforeyouinstalltheserverintoarack
cabinet.Readingandunderstandingtheinformationreducestheriskofpersonalinjuryandor
damagetoyourproduct.
Therackcabinetmustmeetoneofthefollowingrequirements:
Standard4-post(square-hole),19-inchrackcongurationcompliantwithEIA-310-Easdenedbythe
ElectronicIndustriesAlliance
Standard4-post(unthreadedround-hole),19-inchrackcongurationcompliantwithEIA-310-Easdened
bytheElectronicIndustriesAlliance
1
Thedimensionsoftherackcabinetmustmeetthefollowingrequirements:
Figure1.Thedimensionrequirementsoftherackcabinet
1Rearmountingange
2Frontmountingange
3Frontdooroftherackcabinet
Thefollowingtableexplainsthedimensionrequirementsoftherackcabinet.
Table1.Thedimensionrequirementsoftherackcabinet
ItemDimensionsDescription
A
750mm900mm29.53
35.43inches
ItemAreferstothedistancebetweenthefrontmountingange2andthe
rearmountingange
1.Thedistanceshouldbe750mm(29.53inches)in
minimumand900mm(35.43inches)inmaximum.
B
>474mm(18.66inches)
ItemBreferstothewidthoftheserverincludingtherailkitwhentheserver
isinstalledintotherackcabinet.Thewidthshouldexceed474mm(18.66
inches).
D
>60mm(2.36inches)
ItemDreferstothedistancebetweenthefrontmountingange
2andthe
insideofthefrontdooroftherackcabinet3.Thedistanceshouldexceed
60mm(2.36inches).Thisclearanceisrequiredforthechassispullhandles
onthefrontoftheserveraswellasaircirculationthroughthecabinet.
L
>950mm(37.4inches)
ItemLreferstothedistancebetweenthefrontmountingange
2andthe
rearoftheserver.Thedistanceshouldexceed950mm(37.4inches).This
clearanceisusedtosaveadequatespaceforthecablemanagementarm.
Beforeyouinstalltheserverintoarackcabinet,reviewthefollowingguidelinestohelpyouinyourinstallation
andavoidtheriskofpersonalinjuryandordamagetoyourproduct:
Twoormorepeoplearerequiredtoliftaserver,moveaserver,orinstallaserverintoarackcabinet
iftheservermeetsoneofthefollowingcriteria:
2
Theserveris2Uorlarger.(“U”istheunitofmeasurementfordeningtheverticalspaceusedbyyour
serverand1Uisequivalentto4.445cmor1.75inches.)
Theweightoftheserverisratedabove18kg(39.7lbs).Refertothefollowingstatementforsafe
practiceswhenlifting.
18kg(39.7lb)32kg(70.5lb)55kg(121.2lb)
<32kg(70.5lb)<55kg(121.2lb)<100kg(220.5lb)
CAUTION:
Usesafepracticeswhenlifting.
Beforeinstallingaserverintoarackcabinet,removeallmediafromthedrivesandturnoffallattached
devicesandtheserver.Then,disconnectallpowercordsfromelectricaloutletsanddisconnectall
cablesthatareconnectedtotheserver.
Makesurethattheroomairtemperatureisbelow35°C(95°F).
Donotblockanyairvents;usually15cm(6inches)ofspaceprovidesproperairow.
Donotleaveopenspacesaboveorbelowaninstalledserverinyourrackcabinet.Tohelpprevent
damagetoservercomponents,alwaysinstallablankllerpaneltocovertheopenspaceandtohelp
ensureproperaircirculation.
Installtheserveronlyinarackcabinetwithperforateddoor(s)forbothsecurityandproperairow.
Startfromthebottomoftherackcabinetfortheserverordeviceinstallation.
Installtheheaviestserverordeviceinthebottomoftherackcabinet.
Donotextendmorethanoneserverordeviceoutoftherackcabinetatthesametime.
Ifpossible,removethedoorsandsidepanelsoftherackcabinettoprovideeasieraccessduring
installation.
Donotoverloadtheelectricaloutletwhenyouinstallmultipledevicesintherackcabinet.
Connectallpowercordstoproperelectricaloutletsandrefertothedocumentationthatcomeswiththe
rackcabinetforcablinginformationtohelpyouproperlymanageallthecablesintherackcabinet.
Observethefollowingguideline:
CAUTION:
Donotplaceanyobjectontopofrack-mounteddevices.
3
Railkitpackage
Beforeyoubegintherackinstallation,removeallthepartsfromtherailkitpackageshippedwithyour
serverandlayallthepartsonaworkingsurface.
Notes:
Anoptionalcablemanagementarmcanhelpyoutomanageyourcables.ContactyourlocalService
Providertopurchasethecablemanagementarmandrefertothelaterpartofthissectionformore
informationaboutthecablemanagementarm.
Allthepartsrelatedtothecablemanagementarminthefollowingguresaremadeingrey.Thisindicates
thattheyareoptional.
Therailkitpackagecontainsthefollowingparts.Contactyourplaceofpurchaseifanypartismissingor
damaged.
Figure2.Partsintherailkitpackage
1Sliderails(2)5M6x16screws(2)
2Bar-railjoint
6Cablemanagementarm
3Cablemanager
7Arm-railjoint
4#10-32x10screws(2)8Crossbar
4
Theleftsliderailandtherightsliderailarealmostthesame.Theillustrationbelowshowsthecomponentsof
theleftsliderail.
Figure3.Sliderailcomponents
1Frontendofthesliderail3Rearendofthesliderail
2Innerrail
4Outerrail
Note:TheinnersideoftheleftsliderailismarkedwithL.TheletterLstandsforleft.Theinnersideofthe
rightsliderailismarkedwithR.TheletterRstandsforright.
Theillustrationbelowshowsthecomponentsofthecablemanagementarm.
Figure4.Cablemanagementarmcomponents
1ArmmarkedwithA2ArmmarkedwithB
5
Installingyourserverintoarackcabinetusingtherailkit
Beforeyoubegin,removeallthepartsfromtherailkitpackageandlayallthepartsonaworkingsurface.
See“Railkitpackage”onpage4.Thelengthofeachsliderailrangesfrom65cm(25.6inches)when
collapsedto90cm(35.4inches)whenfullyextended.Measuretherackbeforetheinstallationtoensurethat
therackcanaccommodatethesliderail.
Attention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstandingthe“Guidelines”
onpage1.
Toinstalltheserverintoarackcabinetusingtherailkit,dothefollowing:
1.Installtherailkitbydoingthefollowing:
a.Onarearmountingangeoftherightsideoftherackcabinet,selectaproperrackmountingarea
fortherightsliderail.Positiontherearendoftherightsliderailtothemountingareasothatthe
tabsontherearendoftherightsliderailarealignedwiththecorrespondingholesinthemounting
area.Pushtherightsliderailinthedirectionasshowninthegureuntiltherearendoftheright
sliderailisrmlysecuredtothemountingange.
Note:Theholesinamountingangeareseparatedintogroupsbymeasuringmarks.Thethree
holesbetweentwoadjacentmeasuringmarksformagroup,whichindicates1Uspace.Notethe
measuringmarksonamountingangetohelpyoucorrectlyselectarackmountingareaforthe
server.Formoreinformationabouttheplacementoftheholesinamountingange,refertothe
documentationthatcomeswiththerackcabinet.
Figure5.Securingtherearendoftherightsliderailtothemountingange
6
b.Pullupthereleaselatch1onthefrontendoftherightsliderail.Keepthereleaselatchinthe
raisedpositionandpullouttheslideraillock2.
Figure6.Unlockingtheslideraillock
c.Positionthefrontpartoftherightsliderailtothemountingange.Makesurethatthefrontendand
rearendoftherightsliderailareatthesamehorizontallevel.Pushtherightsliderail1untilthe
frontendoftherightsliderailisrmlysecuredtothemountingange.Pushtheslideraillock2
backhorizontallyuntilitislockedintoplace.
Figure7.Securingthefrontendoftherightsliderailtothemountingange
7
d.Repeatsteps1through3toinstalltheleftsliderailtotheoppositesideoftherackcabinet.
2.Installthecablemanagementarmbydoingthefollowing:
a.Turntotherearoftherackcabinet.
b.Alignthebumponthecrossbarwiththedentonthebar-railjoint1.Turnthecrossbarcounter
clockwiseuntilitissecured2.
Figure8.Connectingthecrossbarandthebar-railjoint
c.Alignthebumpontheotherendofthecrossbarwiththedentonthesliderail1.Turnthecrossbar
counterclockwise2untilitissecured.Pullouttheejectbutton3andinsertthebar-railjoint
intothesliderail4.
Figure9.Connectingthecrossbarandthesliderails
8
d.ConnectthearmmarkedwithAandthearm-railjointbypullingouttheejectbutton1andinserting
thearmintothearm-railjoint2.
Figure10.Connectingthecablemanagementarmandthearm-railjoint
e.ConnectthearmmarkedwithBandthesliderailbypullingouttheejectbutton1andinsertingthe
armintothearm-railjoint2.ThenconnectthearmmarkedwithAandthesliderailbypullingout
theejectbutton3andinsertingthearmintothearm-railjoint4.
Figure11.Connectingthecablemanagementarmandthesliderail
9
3.Installtheserverbydoingthefollowing:
a.Fullyextendtheinnerrailsonbothsidesuntiltheinnerrailscannotbepulledoutfurther.
Figure12.Fullyextendingtheinnerrails
10
b.Positiontheserverasshowninthefollowingillustration.Mountandsecurethepairofrailmount
pointsattherear1rst.Thenmountandsecurethepairofrailmountpoints2.Finally,holdand
pressthesliderailstowardstheserveruntiltherailmountpoints3arelockedintoplace.
Figure13.Securingtheserver
11
Thefollowingillustrationshowswhattherailmountpoints3looklikewhenlockedintoplace.
Figure14.Therailmountpointsarelockedintoplace
12
4.Liftthelatch1onbothsidestoreleasetheinnerrails.Gentlyslidetheinnerrailswiththeserver
intotherackcabinet2.
CAUTION:
Toavoidinjurytongers,keephandsfreefromthelatchareawhenthelatchapproachesthe
outerrail.
Figure15.Slidingtheinnerrailswiththeserverintotherackcabinet
13
5.SecuretheservertotherackcabinetwithanM6x16screwonbothsidesofthefrontoftheserver.
Figure16.Securingtheservertotherackcabinet
Trademarks
LenovoandtheLenovologoaretrademarksofLenovointheUnitedStates,othercountries,orboth.
Othercompany,product,orservicenamesmaybetrademarksorservicemarksofothers.
14
SecondEdition
©CopyrightLenovo2012.
LIMITEDANDRESTRICTEDRIGHTSNOTICE:IfdataorsoftwareisdeliveredpursuantaGeneralServicesAdministration
“GSAcontract,use,reproduction,ordisclosureissubjecttorestrictionssetforthinContractNo.GS-35F-05925.
PrintedinChina
(1P)P/N:0A91994
*1P0A91994*
(May2012)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Lenovo ThinkServer RD330 Installation Instructions Manual

Type
Installation Instructions Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI