PRODUCT SAFETY
This camera range is designed for use in general purpose CCTV applications and has no other purpose. Only operate your
camera between the temperatures of -10
O
C and +50
O
C. Do not operate your camera outside its specified power supply range.
Cameras must only be used in clean, dry, dust-free environments unless housed in suitable protective housings to IP65 or better.
In order to avoid damaging the camera note the following points.
1. Installation and servicing is only to be carried out by suitably qualified and experienced personnel.
2. Only power cameras from a class 2 isolated power supply.
3. Do not touch the image-surface of the sensor. If the sensor is accidentally touched, only clean it using isopropanol.
4. Do not expose the sensor to direct sunlight as this may impair the performance of the camera.
5. For outdoor use, an appropriate protective housing conforming to IP65 or UL50 or better must be used.
ELECTROMAGNETIC COMPATIBILITY (EMC)
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may
be required to take adequate measures.
This product is intended solely for use in general CCTV applications.
The product must be installed and maintained in accordance with good installation practice to enable the product to function as
intended and to prevent problems. Refer to Norbain SD Limited for installation guidance.
MANUFACTURERS DECLARATION OF CONFORMANCE
The manufacturer declares that the equipment supplied with this manual is compliant with the essential protection requirements
of the EMC directive 89/336 and the Low Voltage Directive LVD 73/23 EEC. Conforming to the requirements of standards EN 55022
for emissions, IEC801 parts 2, 3 and 4 for immunity and EN 60950 for Electrical Equipment safety.
CONTROLS AND SWITCHES
The diagram below shows the locations and functions of the controls and switches.
Mounting Bolt
Two 1/4 20 UNC mounting bolts are provided for mounting the camera, one on the the top of the case and one on the bottom of
the case.
Lens Level Adustment
If the camera is used with a direct drive (DD) lens this potentiometer varies the DC reference voltage used to control the lens. The
potentiometer has the effect of increasing or decreasing the lens aperture. This potentiometer should be adjusted to obtain a 1V
pk-pk video output and is therefore the factory setting.
Composite Video
To obtain a 1.0V [pk-pk] composite video signal, connect a video coaxial cable terminated with a 75 Ohm BNC connector to the BNC
socket marked VIDEO OUT.
Supply Terminals
These terminals accept a power supply of 12 VDC ±10%, ripple less than 200mV.
EI on/off
The Electronic Iris (EI) compensates for excessive light level by automatically adjusting the shutter speed. The electronic iris
should be ON when using fixed or manual iris lenses. When using Auto Iris DC lenses, the EI must be OFF. See also Lens Level
Adjustment. The default setting is ON.
ON
12
ON
12
BLC ON/OFF
EI ON/OFF
COMPOSITE VIDE
O
SUPPLY
12V DC
M
O
UNTIN
G
B
O
LT
LENS LEVEL
ADJUSTMENT
DIRECT DRIVE LEN
S
CO
NNE
C
T
O
R
MOUNTING BOLT
White denotes switch position
(default settings shown).
HB-VCLV-1 Issue 1 06/02
Norbain SDL Limited, Norbain House, Eskdale Road, Winnersh Triangle, Wokingham, Berkshire RG41 5TS
CONTROLS AND SWITCHES
BLC on/off
The BLC (Back Light Compensation) facility compensates for back-lit scenes by enhancing objects in the centre of the scene
which would previously have been in silhouette. Select ON or OFF using the BLC switch. Default is OFF. BLC will only function with
a manual iris lens when the Electronic Iris facility is switched on. For direct drive lenses, BLC will still function even though the
Electronic Iris facility is switched off.
DD/AI Lens Connector
This 4-pin connector supplies the power and DC control signal for use with Direct Drive Auto Iris lenses. If the lens does not have
a DD plug fitted then wire the lens to a suitable plug in accordance with the diagram below:
Damp (-)
Damp (+)
Drive (+)
Drive (-)
Direct Drive lens connector pin definitions (viewed looking at the connector itself)
LENSES
VC200 series cameras are suitable for CS mount lenses in fixed iris, manual iris or direct drive DC versions. The camera has a
mechanism for adjusting the distance from the back of the lens to the CCD sensor. To adjust, use a suitable tool to loosen the
focus locking screw, then rotate the focus adjustment ring either clockwise or anticlockwise as required. Tighten the focus locking
screw when adjustment is satisfactory.
SPECIFICATIONS
FOCUS LOCKING SCREW
FOCUS ADJUSTMENT RING
Option
Mono
Color
Resolution (TVL)
Sensitivity (lux @ f1.2)
CCD Sensor size
Scanning system PAL
Scanning system CCIR
Electronic Iris (EI) on/off
Digital Signal Processing (DSP)
Auto White Balance
Backlight Compensation (BLC) on/off
Direct (D.C.) Drive Auto Iris connector
Supply
12 VDC ±10%
VC202M
VC212M
VC202C
VC212C
380
1/3”
0.1 0.2 1.0
1.2
570
1/3”
330 470
1/3” 1/3”
Lens Size
1/3”
1/2”
2/3”
1”
VC202M
VC212M
VC202C
VC212C