MicroNet SP3501B Series Quick Installation Guide

Category
Routers
Type
Quick Installation Guide
5
P/N: 2300-0521
Quick Installation Guide
VDSL2 CO / CPE Modem Router
Model No.: SP3501BM/SP3501BS
6
7
Specifications
Model
SP3501BM SP3501BS
3. Power connection
Use the included power adaptor (DC 12V/1A) to connect the
modem power socket to an appropriate power source.
SP3501BM/SP3501BS is default configured for plug-n-play /
auto-sensing operation with SP3501BS/SP3501BM in "switch"
mode for point-to-point networking applications. If router
functionality is desired, please login the system and change the
default setting.
Login the System
1.SP3501BM/SP3501BS provides a built-in web browser. You
can use web browser to configure SP3501BM/SP3501BS.
Please input the IP address 192.168.16.249 (SP3501BM) or
192.168.16.250 (SP3501BS) in the web page.
1.
1.
1.
When prompted enter password "admin" then click [LOGIN]
2.Click Setup Wizard, and the Setup Wizard will lead you step-
by-step through the configuration process. For experienced
users, click Advanced Setup to configure network specific
parameters (IP addresses, etc) and router functionality for
different applications. For more details about configuration,
please refer to user's manual.
1.
1.
1.
1.
1.
Standards
Interface
VDSL
Features
Networking
Power Supply
Emission
IEEE802.3 10BASE-T, IEEE802.3u 100BASE-
TX
ITU-T G993.2 VDSL2
4 x RJ-45 10/100Mbps Ethernet ports
1 x RJ-11 connector for telephone connection
1 x RJ-11 connector for EoVDSL
SNR indicator for check phone wiring quality.
DMT modulation
8a, 8b, 8c, 8d, 12a, 12b, 17a, 17b, and 30a
band profiles
997, 998 band plan
Support 3 / 4 / 5 band
Support bandwidth up to 100Mbps (symmetric)
over 0.3 Km
Support LR-VDSL2 (US0 / DS0 band): range
up to 3 Km (theoretically)
Surge protection for VDSL2 port
PPPoE, Dynamic IP, Static IP
Router / Switch mode
NAT, DHCP, Virtual Server, DMZ, port mapping
Static route
Firewall
UPnP
DC 12V, 1A
CE class A, FCC
Web: www.micronet.com.tw
4
1 2
Introduction
Micronet introduces the next-generation broadband access
solution, with the newest VDSL2 technology, to carriers and
MxU (Multi-Dwelling/Multi-Tenant Units) environments that need
for new services such as IPTV, video conferencing, VoIP, peer-
to-peer file sharing, and interactive gaming. Micronet
SP3501BM / SP3501BS VDSL2 CO / CPE router are fully
compliant with ITU-T G.993.2 VDSL2 standard that is able to
provide the newest broadband solution with ADSL-like long-
reach performance and high-speed symmetrical bandwidth up
to 100Mbps.
Package Contents
Prior to the installation of the device, please verify the following
items are in the package:
VDSL2 CO/CPE Modem Router
SP3501BM VDSL2 CO Modem/Router
SP3501BS VDSL2 CPE Modem/Router
Quick Installation Guide
Manual CD
RJ-11 Cable
RJ-45 Cable
Power Adapter
3
Key Features
ITU-T G993.2 VDSL2 standards fully compliant
Support 8a, 8b, 8c, 8d, 12a, 12b, 17a, 17b, 30a band profiles
Support 997, 998 band plan
Support LR-VDSL2 (US0 / DS0 band)
High-speed symmetric bandwidth up to 100 Mbps over 0.3 Km
Supports auto speed for VDSL2 port
Built-in POTS / ISDN splitter port
Supports PPPoE, UPnP, NAT, DHCP, DMZ, firewall, router /
switch mode
Supports web-based / console management
LINE
(VDSL LED)
LED
Status
Operation
Steady Green
Steady Green
Flashing Green
Steady Green
Device is powering on or reset
ok
Lights up steadily to show good
linkage
Flashing to show data
transmission
Lights up steadily to show good
linkage
Installation
SP3501BM front view
SP3501BS front view
SP3501BM VDSL2 CO Modem / Router
POWER LINELAN1 LAN2 LAN3 LAN4
SP3501BS VDSL2 CPE Modem / Router
POWER LINELAN1 LAN2 LAN3 LAN4
LED definition
LAN1 ~ LAN4
(Ethernet LED)
POWER
SP3501BM/SP3501BS rear view
Modem Rear Connectors
Connecting to the VDSL2 Modem via a
RJ-11 cable
Connecting to the telephone, Fax or ISDN
modem
Connecting to an Ethernet network device
Connecting to PC with RS-232 serial port
over a D-SUB cable
LINE (RJ-11)
PHONE (RJ-11)
LAN1 ~ LAN4 (RJ-45)
CONSOLE (RS232)
Connectors Description
1. DSL and Phone connection
The RJ-11 "Line" port is used to connect to the wall RJ-11
modular socket (outlet), which is used to connect both master
and slave modem (Point to point solution)
The RJ-11 "Phone" port of the Modem can be connected
to a telephone for users sharing the single telephone wire for
making calls and accessing the internet simultaneously.
1 x Console port (monitoring, access to operating system via
shell for firmware downloads, starting drivers and web etc...)
2. LAN connection
The Modem provides 4 Ethernet port, which support
connection through Ethernet operation.
Network devices attached to the Ethernet port must support
auto-negotiation, 10Base-T or 100Base-TX. Otherwise, the
network device must always operate at half duplex.
LAN1LAN2LAN3LAN4 LINE PHONE CONSOLE POWER
DC 12V
Physical Description
Internet
PSTN
RJ-45
RJ-11
SP3501BM
VDSL2 CO Modem Router
SP3501BS
VDSL2 CPE Modem
Router
RJ-45
Ethernet over
VDSL2
2
1
1
2
  • Page 1 1
  • Page 2 2

MicroNet SP3501B Series Quick Installation Guide

Category
Routers
Type
Quick Installation Guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI