be taken not to puncture the inter
walls or remove paint from the w
during this procedure.
Be sure to disconnect power from
cabinet prior to starting
operation. After the cabinet is co
defrosted, wash thoroughly,
defrost water (Hussmann dipping
are provided with an outside
located on the operator’s side of the
base to assist you in this operation), w
the interior dry, and turn the power
on.
Be sure to allow the cabinet to cool dow
to its operating temperature
reloading.
CONDENSING UNIT
–
The condensing unit is mounted on
slideout base, accessible by removing
rear serving side access panel.
condenser is of the baretube design.
condenser fan motor draws the
through the rear access panel, across
compressor and discharges back out
rear access panel unless the case has
Field converted to front air discharge
previously discussed in the
section of this manual.
For this reason, if
the case is installed in a counter, provisions
must be made for the release of the
discharge air.
CLEANING THE CONDENSER –
To clean condenser, a soft, nylon
should be used to loosen dirt and
Then vacuum up the dirt or
condenser out with a high-pressure
such as nitrogen. Never use a wire
to clean condenser tubes.
CLEANING EXTERIOR / INTERIOR –
When cleaning the exterior of the
use a soft cloth or sponge with water
mild detergent. Rinse and wipe dry.
For cleaning the interior of the
compartment, a built-in drain has
provided with a standard hose
located at the front of the cabinet in
base area. Disconnect the
power and allow cabinet to warm
above freezing temperature. Use a
cloth or sponge with a mild detergent
wash the interior. Wipe dry
restarting the cabinet. Allow the
to cool down to proper
before reloadin g produc t.
SERIAL PLA TE LOC A TION
–
One serial plate is located on the interio
left wall of the cabinet, and a second
in the condensing unit
Both contain all pertinent infor
such as model, serial number,
rating, refrigerant type and charge,
Specific charges are DCSG/DCCG-4
oz.,DCSG/DCCG-8 29 oz., DCSG/DCCG-
12 33 oz., and DCSG/DCCG-16 has
oz., all have R-404a. The “D”
have the same charge.
TEMPERATURE CONTROL
REPLACEMENT –
The Ranco temperature control is
in the compressor compartment.
replace, first disconnect power supply
remove two screws holding control
plate. Pull capillary tube from
well, noting length of tube removed.
new cap tube into well, being careful
to kink it, and making certain it
full depth of well.