Lucent Technologies PacketStar PSAX 1000 User manual

  • Hello! I am an AI chatbot trained to assist you with the Lucent Technologies PacketStar PSAX 1000 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Doc. No.: 255-700-240
PacketStar
®
PSAX 1000 Multiservice Media Gateway
User Guide
Issue 2, September 2002
System Software Release 8.0.0
Copyright © 2002 by Lucent Technologies. All rights reserved.
For trademark, regulatory compliance, and related legal information, see
the "Legal Notices, Safety, and Regulatory Information" section.
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
255-700-240 iii
Legal Notices, Safety, and Regulatory
Information
Copyright
Copyright © 2002 by Lucent Technologies. All rights reserved.
This material is protected by the copyright laws of the United States and
other countries. It may not be reproduced, distributed, or altered in any fash-
ion by any entity (either internal or external to Lucent Technologies), except
in accordance with applicable agreements, contracts or licensing, without the
express written consent of the originating organization and the business
management owner of the material.
This document was prepared by the Information Design and Development
Team of Lucent Technologies, PacketStar PSAX products. Offices are located in
Landover, Maryland, USA.
Trademarks
PacketStar, AQueView, Lucent, Lucent Technologies, and the Lucent Technolo-
gies logo are registered trademarks of Lucent Technologies in the USA. Other
product and brand names mentioned in this guide are trademarks or regis-
tered trademarks of their respective owners.
Notices
The information in this document is for informational use only, is subject to
change without notice, and should not be construed as a commitment by
Lucent Technologies, Inc. This document is without warranty of any kind,
either expressed or implied. Lucent Technologies, Inc. assumes no responsi-
bility for any errors, inaccuracies, or omissions. Neither is any liability
assumed for damages resulting from the use of the information or instruc-
tions contained herein. Lucent Technologies, Inc. is not responsible for any
damage or loss to your data or equipment resulting either directly or indi-
rectly from use of this document.
Warranty Information
Software and Hardware Limited Warranties
Lucent Technologies provides a 90-day limited software warranty, and a one-
year limited hardware warranty on this product. Refer to the Software License
and Limited Warranty Agreement and the Lucent Technologies InterNetworking Sys-
tems Global Warranty that accompanied your package for more information.
Legal Notices, Safety, and Regulatory Information
Warranty Information
iv 255-700-240
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
Warranty Warnings
WARNING:
!
Modifying or tampering with PSAX chassis components will void your
warranty. Any modification to this equipment not expressly authorized
by Lucent Technologies will void your granted authority to operate such
equipment.
WARNING:
!
Air filters in the PSAX chassis should be inspected for accumulated dust
and replaced as needed. At a minimum, quarterly inspection of the air fil-
ter is recommended. However, depending on the environmental quality
of the facility more or less frequent inspections may be warranted.
Equipment failure due to inadequate maintenance will void your equip-
ment warranty.
WARNING:
!
Use only air filters supplied by Lucent Technologies in your PSAX chassis.
Use of other air filters will void your equipment warranty.
WARNING:
!
Damage to the module and/or chassis, that is caused by excessive force,
when installing the modules will void your equipment warranty.
WARNING:
!
Shipping the chassis with I/O, server, or CPU modules installed may cause
damage to the chassis and the modules. Damage to any of the compo-
nents in the system resulting from improper shipping methods will void
your warranty.
WARNING:
!
Proper ventilation around the chassis must be maintained to prevent
overheating. Air vents in the PSAX chassis must be regularly inspected
and cleared of dust and blockage. Equipment failure associated with
improper maintenance or suspected failure to adhere to proper ventila-
tion procedures will void your warranty.
WARNING:
!
A minimum of 5.1 cm (2 in.) clearance on each side (left and right) and
the rear of the chassis must be maintained for adequate airflow to pre-
vent equipment failure due to overheating. Failure to provide this clear-
ance between the chassis and any other device/structure will void your
warranty.
255-700-240 v
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
Legal Notices, Safety, and Regulatory Information
Regulatory Standards Compliance
Regulatory Standards Compliance
The PacketStar PSAX 1000 Multiservice Media Gateway, model 10S00, is
compliant with the listed safety, electromagnetic compatibility (EMC) and
telecommunications standards. Applicable statements are provided in the
next subsection.
Safety
UL 1950, Third Edition (USA)
CSA 22.2 No. 950, Third Edition (Canada)
EN 60950:1992+A1:1993+A2:1993+A3:1995+A4:1997 +A11:1997
(Europe)
NOM (Mexico)
AS/NZS 3260:1993+S1:1996 (Australia/New Zealand)
ACA TS 001:1997 (Australia)
CB-Scheme – IEC 60950:1991+A1:1992+A2:1993+A3:1995+A4:1996
(International)
Electromagnetic Compatibility
FCC Part 15 Class A (USA)
ICES-003, Issue 3:1998 Class A/NMB-003 Version 3:1998 classe A
(Canada)
EN 55022:1998 Class A (Europe)
EN 300 386 V.1.3.1 Class A (Europe)
EN 61000-3-2:2000 (Europe)
EN 61000-3-3:1995 (Europe)
AS/NZS 3548:1995+A1:1997+A2:1997 (Australia/New Zealand)
VCCI Class A (Japan)
CISPR 22:1997 Class A (International)
Telecommunications
FCC Part 68 (USA)
CS-03 Issue 8/SH-03 Version 8 (Canada)
ETSI TBR 12:1993+A1:1996 (Europe)
ETSI TBR 13:1996 (Europe)
ETSI TBR 24:1997 (Europe)
TS 016:1997 (Australia)
TS 026:1997 (Australia)
JATE (Japan)
Legal Notices, Safety, and Regulatory Information
Regulatory Statements
vi 255-700-240
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
Regulatory Statements
USA Regulatory Statements
FCC Part 15 This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy, and, if not installed
and used in accordance with this guide, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference; in this case, you would be required to
correct the interference at your own expense.
All cables used to connect to peripherals must be shielded and grounded.
Operation with cables, connected to peripherals, that are not shielded and
grounded may result in interference to radio and television reception.
The user is cautioned that any changes or modifications not expressly
approved by the party responsible for compliance could void the users
authority to operate the equipment.
FCC Part 68 This equipment complies with Part 68 of the FCC rules. On the back of the
PSAX chassis is a label that contains the FCC registration number, in addition
to other information. You must provide this information to the telephone
company, if they request it. The FCC requires Lucent Technologies to provide
you with the following information:
1. This equipment has digital service interface capabilities using RJ-48C and
RJ-48H connectors. The facility interface codes with which this equip-
ment complies for digital services are as follows: 04DU9-BN, 04DU9-DN,
04DU9-1KN, and 04DU9-1SN. This equipment has loop start interface
capabilities using an RJ-11C connector. The facility interface code with
which this equipment complies for service is 02LS2. The service order
codes for this equipment are 6.0F for the T1 interface and 9.0Y for the
loop start interface.
2. An FCC-compliant telephone network interface jack is built into this
equipment and is compatible with interconnections that are Part 68 com-
pliant.
3. The REN for the Voice 2-Wire Office module when used in this equip-
ment is 0.7B.
4. If this equipment causes harm to the telephone network, the telephone
company will notify you in advance that temporary discontinuance of
service might be required. But if advance notice is not practical, the tele-
phone company will notify you as soon as possible. Also, you will be
advised of your right to file a complaint with the FCC if you believe this
is necessary.
5. The telephone company might make changes in its facilities, equipment,
operations, or procedures that could affect the operation of this equip-
ment. If this happens, the telephone company will provide advance
notice for you to make necessary modifications to maintain uninter-
rupted service.
255-700-240 vii
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
Legal Notices, Safety, and Regulatory Information
Regulatory Statements
6. If you experience trouble with this equipment, or need repairs or war-
ranty information, please refer to the Lucent Technologies InterNetworking
Systems Global Warranty that accompanied your PSAX product shipment
for instructions on obtaining technical support in your area.
If this equipment is causing harm to the telephone network, the tele-
phone company might request that you disconnect the equipment until
the problem is resolved.
7. This equipment has no user-serviceable parts.
This equipment cannot be used on public coin telephone service provided by
the telephone company. Connection to party line service is subject to state
tariffs. Contact your state public utility commission, public service commis-
sion, or corporation commission for information.
Underwriters
Laboratories, UL 1950
This product is UL Listed only when supplied with the following assemblies:
Up to four I/O, server, or blank faceplate modules consisting of the following:
Model No. Name
10N04 PSAX 1000 Stratum 34/110/220 V ac Power Supply (up to
two)
10N05 PSAX 1000 Stratum 34/Power Supply module blank faceplate
(one required for nonredundant configuration)
10N10 PSAX 1000 Stratum 34/24 V dc Power Supply (up to two)
10N11 PSAX 1000 Stratum 34/-48 V dc Power Supply (up to two)
10N14 PSAX 1000 Fan/Alarm
10N20 PSAX 1000 CPU3L (up to two)
10N88 PSAX 1000 LIM blank faceplate (two required)
10S00 PSAX 1000 Chassis Assembly
Model No. Name
10N81 PSAX 1000/2300/4500 Blank Single-Slot I/O/CPU Faceplate
10N82 PSAX 1000/2300/4500 Blank Double-Slot I/O/CPU Faceplate
20N02 2-Port DS3 ATM
20N03 1-Port Unchannelized DS3 Frame Relay
20N07 6-Port Multiserial
20N12 1-Port OC-3c Multimode with AQueMan
20N13 1-Port OC-3c Single-Mode with AQueMan
20N14 1-Port OC-3c Multimode with Traffic Shaping
20N15 1-Port OC-3c Single-Mode with Traffic Shaping
20N16 2-Port High Speed
20N28 DSP2B Voice Server
Legal Notices, Safety, and Regulatory Information
Regulatory Statements
viii 255-700-240
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
20N29 DSP2A Voice Server
20N30 8-Port Voice 2-Wire Station
20N32 4-Port Voice 2-Wire Office
20N33 6-Port DS1 IMA
20N36 6-Port Enhanced DS1/T1 Multiservice
20N40 Ethernet
20N41 Route Server
20N72 1-Port OC-3c 1+1 APS Multimode
20N73 1-Port OC-3c 1+1 APS Single-Mode
23N02 3-Port Unstructured DS3/E3 CES
23N03 3-Port Channelized DS3/STS-1e CES
23N07 Quadserial
23N12 1-Port Channelized OC-3/STM-1 CES Multimode
23N13 1-Port Channelized OC-3/STM-1 CES Single-mode
23N25 DSP2F Voice Server
23N26 DSP2E Voice Server
23N27 DSP2C Voice Server
23N28 Tones and Announcements Server
23N29 DSP2D Voice Server
23N33 12-Port Medium-Density DS1 IMA
23N40 4-Port Ethernet
23N60 1-Port Channelized DS3 Multiservice
23N61 1-Port Channelized DS3 CES
23N62 1-Port Channelized STS-1e, T1 Format
23N64 12-Port Medium-Density DS1 Multiservice
23N68 1-Port DS3 IMA
23N72 1-Port OC-12c/STM-4c Multimode
23N73 1-Port OC-12c/STM-4c Single-Mode
23N74 3-Port DS3/E3 ATM
24N64 12-Port Medium-Density DS1/E1/DS0A CES
Model No. Name
255-700-240 ix
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
Legal Notices, Safety, and Regulatory Information
Regulatory Statements
Canadian Regulatory Statements
ICES-003 This Class A digital apparatus complies with Canadian ICES-003.
NMB-003 Cet appareil numérique de la classe A est conforme à la norme NMB-003 du
Canada.
CS-03 Issue 8 NOTICE: This equipment meets applicable Industry Canada Termi-
nal Equipment Technical Specifications. This is confirmed by the reg-
istration number. The abbreviation, IC, before the registration num-
ber signifies that registration was performed based on a Declaration
of Conformity indicating that Industry Canada technical specifica-
tions were met. It does not imply that Industry Canada approved the
equipment.
The Ringer Equivalence Number (REN) assigned to the Voice 2-Wire Office
module denotes the percentage of the total load to be connected to a tele-
phone loop, which is used by the device, to prevent overloading. The termi-
nation on a loop may consist of any combination of devices subject only to
the requirement that the total of the REN of all devices does not exceed 5.
The REN for the Voice 2-Wire Office module when used in the PSAX system
is 0.7B.
SH-03 Version 8 AVIS: Le présent matériel est conforme aux spécifications techniques
d’Industrie Canada applicables au matériel terminal. Cette confor-
mité est confirmée par le numéro d’enregistrement. Le sigle, IC,
placé devant le numéro d’enregistrement, signifie que l’enregistre-
ment s’est effectué conformément à une déclaration de conformité
et indique que les spécifications techniques d’Industrie Canada ont
été respectées. Il n’implique pas qu’Industrie Canada a approuvé le
matériel.
Le nombre équivalent de sonnerie (REN) attribué au module central bifilaire
(Voice 2-Wire Office) correspond au pourcentage de la charge totale à con-
necter à un circuit téléphonique bifilaire; il est utilisé par lappareil pour
prévenir la surcharge. Le circuit peut être terminé par nimporte quelle com-
binaison dappareils, à la seule condition que le total des REN de ces derniers
ne dépasse pas cinq.
Lorsquil est utilisé dans le système PSAX, le module central bifilaire possède
un REN de 0,7 B.
European Union Regulatory Statement
CE-Marking Hereby, Lucent Technologies declares that the PacketStar PSAX 1000
(-48 V dc and 220 V ac), PSAX 1250 (-48 V dc and 220 V ac), PSAX 2300,
and PSAX 4500 Multiservice Media Gateways are in compliance with the
essential requirements and other relevant provisions of the following Council
Directives:
Low Voltage 72/23/EEC
Electromagnetic Compatibility (EMC) 89/336/EEC
Radio Equipment and Telecommunications Terminal Equipment
1999/5/EC
Legal Notices, Safety, and Regulatory Information
Regulatory Statements
x 255-700-240
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
The Lucent PacketStar PSAX Multiservice Media Gateways deployed in the
European Economic Area (EEA) are intended for connection to E1, E3,
STM-1, and STM-4c networks. The EC Declarations of Conformity may be
viewed or printed at the following public-access Internet site:
http://www.lucent.com/ins/doclibrary
EU-regulativer
CE-mærkning Lucent Technologies erklærer hermed at PacketStar PSAX 1000 (-48 V dc og
220 v vekselstrøm), PSAX 1250 (-48 V dc og 220 v vekselstrøm), PSAX 2300,
and PSAX 4500 Multiservice Media Gateways overholder kravene i følgende
EU-direktiver:
Lavspændingsdirektivet 72/23/EEC
EMC-direktivet 89/336/EEC
Direktivet om radio og teleterminaludstyr 1999/5/EC
Lucent PacketStar PSAX Multiservice Media Gateways, anvendt i EØS
(Europæiske Økonomiske Samarbejde) skal forbindes med E1, E3 STM-1 og
STM-4c netværk. EU-overensstemmelseserklæringen er at finde på følgende
internetside hvorfra den også kan udskrives:
http://www.lucent.com/ins/doclibrary
Behördliche Standard-CE-Kennzeichnung für die Europäische Gemeinschaft
CE-Markierung Hiermit erklärt Lucent Technologies, dass die PacketStar PSAX 1000
(-48 V DC und 220 V~), PSAX 1250 (-48 V DC und 220 V~), PSAX 2300,
und PSAX 4500 Multiservice Media Gateways die notwendigen Anforderun-
gen und anderen relevanten Vorschriften der folgenden Council-Direktiven
einhalten:
Niederspannungsdirektive 72/23/EEC
Elektromagnetische Verträglichkeit (EMC) 89/336/EEC
Funkgeräte und Funkverkehr-Endeinrichtungen 1999/5/EC
Die Lucent PacketStar PSAX Multiservice Media Gateways, die in der
Europäischen Gemeinschaft im Einsatz stehen, dienen zum Anschluss an fol-
gende Netztypen: E1, E3, STM-1 und STM-4c. Die Konformitätserklärung für
die Europäische Gemeinschaft kann auf folgendem, öffentlich zugänglichem
Internet-Site eingesehen oder ausgedruckt werden:
http://www.lucent.com/ins/doclibrary
¥²³²·¸¯¢q¶¢¸½´³¸¬»}½¶º´¥¿¯»²º·¬»
tÄ¥²·¬&( ©¸³´¥¶¢²¬/XFHQW7HFKQRORJLHV¨¬°µ²©¢¸¸¥PacketStarPSAX1000
(
-48Vdc¯¥9DF), PSAX1250 (-48Vdc¯¥9DF), PSAX2300, ¯¥
PSAX0XOWLVHUYLFH0HGLD*DWHZD\V©²¥¶±³²¡¾³²¸¥±©¸»¦¥·¯»
¥´¥¸·©»¯¥°³´»·¼©¸¯»¨¥¸®©»¸º²¨¬«µ²¸³½t½±¦³½°¡³½
¥±¬°¸·¬(2.
+°©¯¸¶³±¥«²¬¸¯·½±¦¥¸¢¸¬¸¥(0&(2.)
¥¨³ªº²¯¢»©®³´°·±¢»¯¥}®³´°·±¢»¸©¶±¥¸¯³¤¸¬°©´¯³²º²µ²
(.
255-700-240 xi
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
Legal Notices, Safety, and Regulatory Information
Regulatory Statements
¥/XFHQW3DFNHW6WDU36$;0XOWLVHUYLFH0HGLD*DWHZD\V´³½¼³½²
¸³´³¹©¸¬¹©¡·¸³²}½¶º´¥¿¯¢¯³²³±¯¢µ¶³}}y´¶³³¶¡¾³²¸¥«¥
·¤²¨©·¬±©¸¥¨¡¯¸½¥((670¯¥670F m¬°µ·©»}²¥¶±¢²·¬»
¸¬»}±´³¶³¤²²¥´¶³¦°¬¹³¤²²¥¸½´º¹³¤²¥´¢¸¬²´¥¶¥¯¸º´¶³·¸
·¸³¯³²¢¸³´³¹©·¡¥¸³½²¸©¶²©¸
KWWSZZZOXFHQWFRPLQVGRFOLEUDU\
Euroopan unionin sääntelystandardi
CE-merkki Lucent Technologies vakuuttaa täten, että PacketStar PSAX 1000 (-48 V dc ja
220 V vaihtovirtaa), PSAX 1250 (-48 V dc ja 220 V vaihtovirtaa), PSAX 2300,
ja PSAX 4500 Multiservice Media Gatewayt täyttävät seuraavien neuvoston
direktiivien keskeiset vaatimukset ja asiaankuuluvat määräykset:
Pienjännite 72/23/EY
Sähkömagneettinen yhteensopivuus (EMC) 89/336/EY
Radiolaitteet ja telepäätelaitteet 1999/5/EY
Lucent PacketStar PSAX Multiservice Media Gatewayt, joita käytetään
Euroopan talousalueella, on tarkoitettu liitettäväksi E1-, E3-, STM-1- ja
STM-4c-verkkoihin. EU:n vaatimustenmukaisuusvakuutus voidaan nähdä
tai tulostaa seuraavalta julkiselta Internet-sivulta:
http://www.lucent.com/ins/doclibrary
Norme réglementaire de lUnion européenne
Label CE Lucent Technologies déclare en ceci que les passerelles de média multiser-
vices PacketStar PSAX 1000 (-48 V c.c. et 220 V ca), PSAX 1250 (-48 V c.c. et
220 V ca), PSAX 2300, et PSAX 4500 sont conformes aux exigences essen-
tielles et autres dispositions pertinentes des directives suivantes du Conseil:
Basse tension 72/23/CEE
Compatibilité électromagnétique (CEM) 89/336/CEE
Matériel radio et terminaux de télécommunications 1999/5/CE
Les passerelles de média multiservices PacketStar PSAX de Lucent, commer-
cialisées dans lEspace économique européen sont destinées aux connexions
à des réseaux E1, E3, STM-1 et STM-4c. Les déclarations de conformité CE
peuvent être consultées ou imprimées à partir du site Internet daccès public:
http://www.lucent.com/ins/doclibrary
Normativa dellUnione Europea
Apposizione del
marchio CE
La Lucent Technologies dichiara che i gateway multiservizio PacketStar
PSAX 1000 (-48 V dc e 220 V c.a.), PSAX 1250 (-48 V dc e 220 V c.a.),
PSAX 2300, e PSAX 4500, rispondono ai requisiti essenziali ed ad altre
norme rilevanti delle seguenti direttive del Consiglio:
Direttiva 72/23/CEE Basse tensioni
Direttiva 89/336/CEE sulla compatibilità elettromagnetica
Direttiva 1999/5/CE riguardante le apparecchiature radio e le apparecchia-
ture terminali di telecomunicazione
Legal Notices, Safety, and Regulatory Information
Regulatory Statements
xii 255-700-240
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
I gateway multiservizio Lucent PacketStar PSAX impiegati nellarea econom-
ica europea (EEA), sono concepiti per il collegamento con reti E1, E3, STM-1
e STM-4c. Le dichiarazioni di conformità CE possono essere stampate o
visionate presso il seguente sito Internet di pubblico accesso:
http://www.lucent.com/ins/doclibrary
Norm van de Europese Unie
CE-markering Lucent Technologies verklaart hierbij dat de PacketStar PSAX 1000 (-48 V dc
en 220V wisselstroom), PSAX 1250 (-48 V dc en 220V wisselstroom),
PSAX 2300, en PSAX 4500 Multi Service Media Gateways voldoen aan de
essentiële vereisten en andere relevante bepalingen van de volgende Rich-
tlijnen van de Raad:
Laagspanning 72/23/EEG
Elektromagnetische compatibiliteit (EMC) 89/336/EEG
Radioapparatuur en telecommunicatie-eindapparatuur 1999/5/EG
De Lucent PacketStar PSAX Multi Service Media Gateways die in de Europese
Economische Ruimte (EER) zijn ingezet, zijn bestemd voor aansluiting op E1,
E3, STM-1 en STM-4c netwerken. DE EU-verklaringen van overeenstem-
ming kunnen worden bekeken of afgedrukt op de volgende Internet-site met
openbare toegang:
http://www.lucent.com/ins/doclibrary
Padrão Regulador da União Europeia
CE-Marcação /
Características
A Lucent Technologies vem por este meio declarar que os Concentradores de
Acesso PacketStar PSAX 1000 (-48 V dc e 220V CA), PSAX 1250 (-48 V dc e
220V CA), PSAX 2300, e PSAX 4500 obedecem aos requisitos essenciais e a
outras disposições relevantes das seguintes Directivas do Conselho:
Baixa Voltagem 72/23/EEC
Compatibilidade Electromagnética (EMC) 89/336/EEC
Equipamento de Rádio e Equipamento Terminal de Telecomunicações
1999/5/EC
Os Concentradores de Acesso PacketStar PSAX da Lucent instalados na Área
Económica Europeia (EEA) foram concebidos para serem ligados a redes do
tipo E1, E3, STM-1 e STM-4c. As Declarações de Conformidade CE podem
ser vistas ou impressas no seguinte sítio de acesso público da Internet:
http://www.lucent.com/ins/doclibrary
Norma reguladora de la Unión Europea
Marcas de la CE Por el presente, Lucent Technologies declara que las pasarelas de medios
multiservicio PacketStar PSAX 1000 (-48 V cc y 220 V ca), PSAX 1250
(-48 V cc y 220 V ca), PSAX 2300, y PSAX 4500 Multiservice Media Gate-
ways están en conformidad con los requisitos esenciales y otras disposiciones
pertinentes de las siguientes directrices del consejo:
Bajo voltaje 72/23/EEC
Compatibilidad electromagnética (EMC) 89/336/EEC
Equipo de radio y equipo de terminales de telecomunicaciones 1999/5/EC
255-700-240 xiii
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
Legal Notices, Safety, and Regulatory Information
Regulatory Statements
Las pasarelas de medios multiservicio Lucent PacketStar PSAX Multiservice
Media Gateways desplegadas en el área económica europea (European Eco-
nomic Area, EEA) están destinadas a conectarse en redes E1, E3, STM-1 y
STM-4c. Las declaraciones de conformidad de la CE pueden verse o
imprimirse en el siguiente sitio Internet de acceso público:
http://www.lucent.com/ins/doclibrary
Europeiska unionens standardförordning
CE-märkning Lucent Technologies deklarerar härmed att PacketStar PSAX 1000
(-48 V likström och 220 V växelström), PSAX 1250 (-48 V likström och
220 V växelström), PSAX 2300, och PSAX 4500 Multiservice Media Gate-
ways uppfyller de väsentliga kraven och andra relevanta bestämmelser som
gäller enligt följande Europarådsdirektiv:
Lågspänning 72/23/EEC
Elektromagnetisk kompatibilitet (EMC) 89/336/EEC
Radioutrustning och telekommunikationskopplingsutrustning 1999/5/EC
Lucent PacketStar PSAX Multiservice Media Gateways, som är placerad i EEA
(European Economic Area), är avsedd för att anslutas till E1, E3, STM-1 och
STM-4c nätverk. Europarådets Konformitetsdeklarationer kan ses på bild-
skärm eller skrivas ut på följande, för allmänheten tillgängliga Internet-ställe:
http://www.lucent.com/ins/doclibrary
EN 300 386 This equipment is a Class A digital device, intended for installation only
within telecommunication centers.
Japanese Regulatory Statements
VCCI This is a Class A product based on the standard of the Voluntary Control
Council for Interference by Information Technology Equipment (VCCI). If
this equipment is used in a domestic environment, radio disturbance may
occur, in which case, the user may be required to take corrective actions.
JATE This equipment complies with the Japan Approvals Institute for Telecommu-
nication Equipment (JATE) requirements when used in conjunction with the
I/O modules listed in Table 1.
Legal Notices, Safety, and Regulatory Information
Regulatory Statements
xiv 255-700-240
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
CISPR 22, EN 55022, AS/NZS-3548 Class A EMC Regulatory Statement
This is a Class A product. In a domestic environment, this product may cause
radio interference, in which case the user may be required to take adequate
measures.
Table 1. JATE Approved Modules
Module
Model
Number
Module Description
Jate
Approval
Number
20N33
6-Port DS1 IMA (
IMA DS1)
D00-0807
20N36
6-Port Enhanced DS1/T1 Multiservice (
DS1/T1 Enh)
D00-0807
20N62
1-Port STM-1 Multimode with AQueMan (
STM-1 (MM AQ))
L00-0198
20N63
1-Port STM-1 Single-Mode with AQueMan (
STM-1 (SM AQ))
L00-0198
20N64
1-Port STM-1 Multimode with Traffic Shaping (
STM-1 (MM TS))
L00-0198
20N65
1-Port STM-1 Single-Mode with Traffic Shaping (
STM-1 (SM TS))
L00-0198
20N92
1-Port STM-1 1+1 MSP Multimode (
STM-1 MM MSP)
L00-0230
20N93
1-Port STM-1 1+1 MSP Single-Mode (
STM-1 SM MSP)
L00-0230
255-700-240 xv
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
Contents
Legal Notices, Safety, and Regulatory Information . . . . . . . . . . . . . . . . . iii
Copyright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Software and Hardware Limited Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Warranty Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Regulatory Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Electromagnetic Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Telecommunications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
USA Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
FCC Part 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
FCC Part 68 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
Underwriters Laboratories, UL 1950 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .vii
Canadian Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
ICES-003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
NMB-003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
CS-03 Issue 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
SH-03 Version 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
European Union Regulatory Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
CE-Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
EN 300 386 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
Japanese Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
VCCI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
JATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
CISPR 22, EN 55022, AS/NZS-3548 Class A EMC Regulatory Statement . . . . . . . . . . . xiv
List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxx
List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxiv
1 Getting Started. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Purpose of This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Audience for This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Contents
255-700-240 xvi
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
What You Should Know . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Related Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Product Information Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Printed Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Other Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Text Types Used in This Document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Icons and Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
Command Description Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
Field Description Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4
Selecting Options, Fields, and Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4
Help Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7
About Lucent Technologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7
History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7
For More Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7
About the PacketStar PSAX Product Family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7
PSAX 1000 Multiservice Media Gateway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8
PSAX 1250 Multiservice Media Gateway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8
PSAX 2300 Multiservice Media Gateway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8
PSAX 4500 Multiservice Media Gateway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9
Comments on This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-10
2 Hardware Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1
System Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1
System Hardware Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1
Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2
Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2
Module Slot Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Module Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4
CPU3L (or CPU2) Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4
Stratum 3–4/Power Supply Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4
Blank Faceplates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4
6-Port Multiserial Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4
I/O and Server Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4
Midplane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4
Stratum 3–4/Power Supply Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5
-48 V dc Power Supply Component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5
Contents
255-700-240 xvii
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
110/220 V ac Power Supply Component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5
24 V dc Power Supply Component. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6
Chassis Throughput . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-7
Timing Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-7
Timing Sources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-8
Redundant System Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-8
Timing Source Failures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-8
Chassis Temperature Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-8
Trap Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-9
Fan/Alarm Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-9
Alarm Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-9
Alarm Relay Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10
Audible Alarm Cutoff (ACO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-12
Remote Status Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-13
Chassis Temperature Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-14
CPU3L (or CPU2) Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-14
Hardware Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-15
Chassis Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-15
System Environmental Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-16
Stratum 34/Power Supply Module Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . .2-16
CPU3L (or CPU2) Module Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-18
PacketStar I/O and Server Module Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-19
Module Performance and Power Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-19
3 System Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
System Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
PSAX System User Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
PSAX System Feature Highlights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Interface Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2
Connections Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-3
Soft Permanent Virtual Circuit (SPVC) Connections . . . . . . . . . . . . . . . . . . . . . . . . . . .3-3
SPVC Reconnection Prioritization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Switched Virtual Circuit (SVC) Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6
SVC Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7
Call States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7
User Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-10
Circuit Emulation Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-10
SPVC Support for CES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-10
Contents
255-700-240 xviii
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
Circuit Emulation Service for the Multiserial Module. . . . . . . . . . . . . . . . . . . . . .3-10
Dynamic Bandwidth Circuit Emulation Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-11
Dynamic CAC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-11
DS1 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-11
DS3 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-12
HDLC Passthrough Bit Inversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-12
Interim Interswitch Signaling Protocol (IISP) Interface. . . . . . . . . . . . . . . . . . . . . . . . .3-12
Private Network-Network Interface (PNNI) 1.0. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-12
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-12
PNNI Features Supported by the PSAX Systems. . . . . . . . . . . . . . . . . . . . . . . . . .3-13
PNNI Peer Group Dynamics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-13
PNNI Topology State Element (PTSE) Information . . . . . . . . . . . . . . . . . . . . . . . .3-14
PNNI Hierarchies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-14
ATM Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-16
Integrated Link Management Interface (ILMI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-17
ILMI over PNNI Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-17
Load Balancing for IISP and PNNI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-18
ATM Terminal Emulation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-18
UNI 4.0 Signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-18
Inverse Multiplexing for ATM (IMA). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-19
Automatic Use of IMA Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-19
IMA Configuration Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-19
Frame Relay-to-ATM Interworking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-20
FRF.5 Encapsulating Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-20
FRF.8 Converting Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-20
Frame Relay-to-Frame Relay Interworking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-20
GR-303 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-21
Network Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-23
Network Management Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-23
AQueView
®
Element Management System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-24
Multiservice Media Gateway Software Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-25
Connection Gateway API . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-25
Connection Gateway API Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-25
The PSAX 1000 As a TCP Client/Server for the Connection Gateway API . . . . . .3-26
DS1 ANI In-line Codes for Loopbacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-27
DS0A Non-Latched Loop Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-27
PSAX 1000 System Traffic Protection Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . .3-28
APS/MSP Protection on the Optical Modules . . . . . . . . . . . . . . . . . . . . . . . . . . .3-28
Interface Protection Group Feature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-29
Contents
255-700-240 xix
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
Alternate Rerouting Using Dual-Homed PVCs. . . . . . . . . . . . . . . . . . . . . . . . . . .3-30
Firmware Release Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-32
H.248 Media Gateway Access Protocol. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-33
Forward Error Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-33
Internet Protocol (IP) Throttling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-35
LANET Protocol. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-35
Operations, Administration, and Maintenance (OAM). . . . . . . . . . . . . . . . . . . . . . . .3-38
Overview of OAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-38
OAM Cell Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-38
OAM ATM Layer Flows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-39
OAM F4 Flows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-40
OAM F5 Flows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-40
ATM Layer OAM Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-41
Packet Pipe AAL5-to-AAL2 Wireless Trunking for Mobile Voice . . . . . . . . . . . . . . . . .3-42
Reduction in Post-Dial Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-43
Trap Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-43
Traffic Management Using the AQueMan Algorithm. . . . . . . . . . . . . . . . . . . . . . . . .3-43
ATM Traffic Management (UPC Support) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-47
Cell Bus Traffic Shaping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-47
ATM Traffic Shaping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-50
Overview of ATM Traffic Shaping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-50
Configuring ATM Traffic Shaping for HDLC, Frame Relay, and Ethernet Virtual
Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-50
Task Summary for Implementing ATM Traffic Shaping. . . . . . . . . . . . . . . . . . . . .3-51
VBR ATM Traffic Shaping Priorities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-51
ATM Traffic Shaping for CBR and VBR-rt. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-51
Maximum Number of ATM Traffic-Shaped Connections . . . . . . . . . . . . . . . . . . .3-52
How the ATM Traffic Shaping Algorithm Works . . . . . . . . . . . . . . . . . . . . . . . . .3-52
Formula for Determining the PCR of an ATM Traffic-Shaped Connection . . . . . .3-53
V5.2 European IDLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-54
Virtual Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-54
Voice Compression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-55
Voice Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-55
Echo Cancellation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-55
Wireless Mobile Voice Backhaul . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-55
Virtual Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-56
PSAX Module Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-59
Contents
255-700-240 xx
PacketStar
®
PSAX 1000 Multiservice Media Gateway User Guide, Issue 2 Release 8.0.0
4 Using VT100 Terminal Emulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
Setting Up The Windows HyperTerminal Emulator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
Connecting a Dialup Modem to the Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3
5 Site-Specific Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1
Logging onto the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1
Changing the System Password and Other User Options . . . . . . . . . . . . . . . . . . . . . . . . . .5-4
Console Interface Main Menu Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-8
Site-Specific Configuration Menu Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-8
Configuring the System for Your Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-9
Accessing the Site-Specific Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-10
Configuring System Identification Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-13
Rules for Configuring IP Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-15
Rules for Configuring IP Address Masks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-16
Configuring System Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-16
Configuring System Date and Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-19
Configuring the PSAX System as a TCP Server or a TCP Client . . . . . . . . . . . . . . . . .5-20
Configuring SNMP Trap Destinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-23
Configuring Call Control Resource Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-25
Setting the Configuration Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-25
Saving the Configuration and Rebooting the System . . . . . . . . . . . . . . . . . . . . . . . .5-31
Backing Up Configuration Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-33
Configuring GR-303 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-33
Configuring TAS Module System-Wide Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-33
Configuring H.248 (Media Gateway Control Protocol). . . . . . . . . . . . . . . . . . . . . . . . . . .5-34
Configuring DSP Resource Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-34
Enabling and Disabling System-Wide Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-34
Rebooting Redundant or Non-Redundant PSAX System CPUs . . . . . . . . . . . . . . . . . . . . .5-38
Configuring Interface Protection Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-42
Setting Up an Interface Protection Group ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-42
Creating an Interface Protection Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-46
Internet Protocol (IP) Throttling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-50
SNMP Trap Activation/Deactivation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-55
Enabling and Disabling SNMP Trap Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-56
Trap Activation Table Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-56
Using the Equipment Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-58
Setting the Stratum Configuration Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-63
/