ADTRAN TOTAL ACCESS 4303 DS3 Installation and Maintenance

Type
Installation and Maintenance

ADTRAN TOTAL ACCESS 4303 DS3 combines with the Total Access 4303 base unit and other Total Access 4303 modules to support requirements calling for multiple DSX-1 circuits. It includes extensive performance monitoring of the DS3 or individual DS1 circuits, inherent DACS capability, and compliance with ANSI T1.102, ANSI T1.403, AT&T 54016, and AT&T 62411. Provisioned by software only, the device does not require any hardware switches, and it offers local and remote line and payload loopbacks as well as QRSS test pattern available per port.

ADTRAN TOTAL ACCESS 4303 DS3 combines with the Total Access 4303 base unit and other Total Access 4303 modules to support requirements calling for multiple DSX-1 circuits. It includes extensive performance monitoring of the DS3 or individual DS1 circuits, inherent DACS capability, and compliance with ANSI T1.102, ANSI T1.403, AT&T 54016, and AT&T 62411. Provisioned by software only, the device does not require any hardware switches, and it offers local and remote line and payload loopbacks as well as QRSS test pattern available per port.

Section 61200333L1-5B
Issue 2, October 2002
CLEI Code: SLL3WY0J_ _
61200333L1-5B 1
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
Contents
1. GENERAL ............................................................ 1
2. INSTALLATION.................................................. 2
3. PROVISIONING .................................................. 3
4. MAINTENANCE................................................ 11
5. SPECIFICATIONS ............................................. 11
6. WARRANTY AND CUSTOMER SERVICE.... 11
Figures
Figure 1. Total Access 4303 DS3 Module ................ 1
Figure 2. DS3 Menu Tree.......................................... 4
Figure 3. Modules Menu ........................................... 5
Figure 4. Menu Options............................................. 6
Figure 5. Network Loopback Tests ........................... 8
Tables
Table 1. Compliance Codes ..................................... 2
Table 2. Front Panel LEDs....................................... 3
Table 3. DS3 Module Specifications ..................... 12
1. GENERAL
This document provides installation and maintenance
procedures for the ADTRAN Total Access 4303 DS3
Module (P/N 1200332L1, see Figure 1).
Revision History
This is the second release of this practice. This version
includes general documentation updates and the
addition of the DS3 Menu Tree.
Description
The Total Access 4303 DS3 Module is a member of the
Total Access 4303 family of integrated access products.
It provides a single channelized DS3 interface. The
module terminates all 28 DS1s of a channelized DS3
into the Total Access 4303 TDM backplane for use in
GR-303 applications or in a DACS. Any of the 28 DS1
circuits or the DS3 receive clock can serve as the
primary or backup timing source for the entire system.
The DS3 Module combines with the Total Access 4303
base unit and other Total Access 4303 modules to
support requirements calling for multiple DSX-1
circuits.
Figure 1. Total Access 4303 DS3 Module
Typical applications calling for Total Access 4303 and
the DS3 Module include the following:
•GR-303
Digital Access Cross Connect System (3/1/0
DACS). Any DS0 on any DS1 circuit can be
switched to any other DS0 on any other DS1 circuit.
DS3 Bandwidth Management. A DS3 circuit carry-
ing voice, data, and other traffic can have its pay-
load groomed and directed to the appropriate
interface inside the Total Access 4303 system.
Features
The DS3 Module includes the following features:
Provisioned by software only - no hardware
switches
Local and remote line and payload loopbacks as
well as QRSS test pattern available per port
Compliant with ANSI T1.102, ANSI T1.403,
AT&T 54016, and AT&T 62411
1200333L1
ONLINE
STATUS
DS3
DS3
Total Access
®
4303 DS3 Module
Installation and Maintenance Practice
2 61200333L1-5B
Various timing options; automatically switches to
local timing if LOS is detected on selected timing
source
Inherent DACS capability
Extensive performance monitoring of the DS3 or
individual DS1 circuits
DS3 maintenance data link support
Software configurable line build out
Meets NEBS Level 3 and UL 60950 standards
Functional Description
The DS3 Module will install into any of the first four
option slots (labeled 1 through 4) in the Total Access
4303 chassis. The status of the module can be viewed,
as well as the circuits to which it interfaces, via the
terminal menus. The terminal menus are accessible
through either a VT100 terminal connected to the Total
Access 4303 base unit’s control port or through a Telnet
session established through the base unit’s Ethernet
port. Use the terminal menu to configure the DS3
Module and to download application software.
The Total Access 4303 system is composed of a 19-inch
chassis housing, two power supplies, two SCUs, and
sixteen option slots. The DS3 Module’s physical
interface is provided on the Total Access 4303 chassis
backplane using the BNC Module (P/N 1200323L1).
The Total Access 4303 backplane delivers two
-48 VDC buses to the DS3 Module. The DS3 Module
operates with either or both buses active.
Physical Description
The front panel of the DS3 Module displays the module
name, part number, CLEI code and status LEDs. The
module name, part number, and CLEI code may also be
found through the terminal menus. The dimensions of
the card itself are approximately 6 inches in height, 0.88
inches in width, and 10 inches in depth.
Compliance
Table 1 shows the Compliance Codes for the Total
Access 4303 DS3 Module. The DS3 Module is NRTL
listed to the applicable UL standards. The DS3 Module
is to be installed in a restricted access location and in a
Type “B” or “E” enclosure only.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received,
including interference that may cause undesired
operation.
Changes or modifications not expressly approved by
ADTRAN could void the user’s authority to operate this
equipment.
2. INSTALLATION
After unpacking the DS3 Module, inspect it for damage.
If damage has occurred, file a claim with the carrier,
then contact ADTRAN Customer Service (refer to
Warranty and Customer Service on page 11). If
possible, keep the original shipping container for
returning the DS3 Module for repair or for verification
of shipping damage.
Shipping Contents
The contents include the following items:
•DS3 Module
DS3 Module Job Aid
Electronic modules can be damaged by static electrical
discharge. Before handling modules, wear an antistatic
wrist strap to prevent damage to electrical components.
Place modules in antistatic packing material when
transporting or storing.
Instructions for Installing the Module
Follow the steps below to install the module.
NOTE
Hot insertion of the module is permissable.
WARNING
Dangerous voltage is exposed when the cover
plate is removed.
Table 1: Compliance Codes
&RGH ,QSXW 2XWSXW
3RZHU&RGH3& ) &
7HOHFRPPXQLFDWLRQ&RGH7& ± ±
,QVWDOODWLRQ&RGH,& $ ±
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
61200333L1-5B 3
1. If present, remove the cover plate from the appro-
priate option slot (labeled 1-4) of the Total Access
4303 chassis.
2. Position the module to fit in the lower and upper
grooves.
3. Slide the module into the option slot pressing
equally on the top and bottom of the front panel
until the module is firmly positioned against the
back of the chassis.
4. Push in the ejector on the lower left-hand side of
the module to finish seating the module.
Auto-detection of Modules
The Total Access 4303 SCU automatically detects the
presence of the DS3 Module when the module is
installed into the system. Rebooting is not required.
Wiring Connections
The DS3 physical interface is provided on the Total
Access 4303 chassis backplane using the BNC Module
(P/N 1200323L1). This module provides a dual 75-ohm
BNC connector.
Font Panel LEDs
See Table 2 for a description of the front panel LEDs.
3. PROVISIONING
The DS3 Module can be configured and controlled from
a variety of sources, including the following:
The terminal menus, allowing detailed configura-
tion, status, and diagnostics
SNMP, primarily for reporting alarm conditions
and system status (not currently supported)
NOTE
The remainder of this document describes the
menu items available when managing the DS3
Module via the terminal menus.
The Terminal Menus
The terminal menus are available by using either a
VT100 terminal attached to the Total Access 4303
active SCU’s craft port, the chassis’ ADMIN port, or a
Telnet session established through the SCU’s Ethernet
port. The Total Access 4303 System Manual, Section 6
(DLP-610) provides detailed instructions on using any
of these management approaches.
Terminal Menu Structure
The
Total Access 4303
uses a hierarchical menu
structure to provide access to all of its features. The top-
most menu level leads to submenus which are grouped
by functionality. All menu items display in the terminal
window. Figure 2 illustrates the DS3 menu tree.
Table 2: Front Panel LEDs
21/,1(/('&RORUV 'HVFULSWLRQ
2II %ORZQIXVH
QRSRZHUSUHVHQW
*UHHQ 2QOLQH
%OLQNLQJ*UHHQ 2IIOLQH
5HG &DUGIDLOXUH
%OLQNLQJ5HG 6HOIWHVWIDLOXUH
$PEHU 6HOIWHVWLQSURJUHVV
'6/('&RORUV 'HVFULSWLRQ
2II '6'6QRWFRQILJXUHGIRU
XVH
*UHHQ '6'6VLJQDOSUHVHQWDQG
V\QFKURQL]HGFKDQQHOLV
FRQILJXUHGIRUXVH
5HG '6'6DODUPSUHVHQW
%OLQNLQJ5HG '6'6HUURU
$PEHU '6'6WHVWLQSURJUHVV
LQFOXGHVSRUWVHOIWHVW
6WDWXV/('&RORUV 'HVFULSWLRQ
*UHHQ $FWLYH'60RGXOH
%OLQNLQJ*UHHQ 6WDQGE\'6ZLWKUHGXQGDQF\
HQDEOHG
%OLQNLQJ5HG 6WDQGE\'6WKDWFDQQRWDXWR
PDWLFDOO\EHFRPHWKHDFWLYH
'6ZKLOHWKHFXUUHQWDFWLYH
'6LVLQVWDOOHG
4 61200333L1-5B
Figure 2. DS3 Menu Tree
Slt
Type
Menu
Alarm
Test
State
Rev
Modules
Part Number
Serial Number
CLEI Code
Board Revision
Prt
Rx Alarms
Far End Alarms
CBIT Status (Rx Framing)
Prt
Clear
ES_L
SES_L
LOSS_L
CV_P
ES_P
SAS_P
SES_P
UAS_P
DS3 Info
DS3 Alarm Status
Prt
Port Name
Frame Format
Clock Source
LBO
DS3 Configurations
Prt
LoopBack
Remote LB
Remote Status
DS3 Test
DS1 Alarm Status
DS1 DS0 Status
DS1 DS0 Alarm
DS1 Sig Status
Prt
T1 Alarms
RED
YELLOW
BLUE
DS0 Alarm
Prt
Clr
ES
BES
SES
SEFS
LOFC
CSS
UAS
PCV
Prt
Port Name
Frame Format
Auto TX Yellow Alarm
Transmit PRMs
Loopback Accept
Rmt Mgmt Over FDL
Prt
Local Loopback
Remote Loopback
Test Pattern
QRSS/RLB Results
QRSS Pattern Results Clear
QRSS Pattern Error Inject
DS1 Test
Redundancy
Module Redundancy
Error Threshold
Minimum Switch Time
Switch Count
Clear Switch Count
Force Switchover
Disabled
1E-03
1E-04
1E-05
1E-06
DS1 Config
DS3 Perf Current
DS3 Perf 15 Min
DS3 Perf 24 Hr
DS1 Perf Current
DS1 Perf 15 Min
DS1 Perf 24 Hr
61200333L1-5B 5
Accessing the Module Terminal Menus
Once connected to a terminal, press
Enter
several times
until a
L
OGIN
prompt displays. Enter the default
password, password, in lower case characters (the login
system is case sensitive). The Total Access 4303 upper-
level
S
YSTEM
I
NFO
menu opens.To access the terminal
menu for the DS3 Module:
1. Use the arrow keys to navigate to the
M
ODULES
menu and press
Enter
.
2. Select the module by using the arrow keys to
highlight the specific module.
3. Press
Enter
while the module slot is highlighted.
Menu options for the module now display on the
terminal.
NOTE
Refer to the Total Access 4303 System Manual
for detailed instructions on navigating through
the terminal menu.
Passwords
To edit fields in the terminal menus, the appropriate
password level must be obtained. Each menu
description in this section indicates the password level
required for write and read access. Security level 0 users
can view and edit every available field. Security level 5
users can view most fields but cannot edit.
M
ODULES
M
ENU
Figure 3 shows the
M
ODULES
menu. DS3 identifies the
DS3 Module. The following sections describe the
M
ODULES
menu options: S
LT
, T
YPE
, M
ENU
, A
LARM
,
T
EST
, S
TATE
, S
TATUS
, and R
EV
.
Figure 3. Modules Menu
S
LT
Read security: 5
Displays the slot number for available option slots in the
Total Access 4303 chassis. This field is read-only.
T
YPE
Read security: 5; Write security: 3
Displays either the type of module currently installed in
the slot or the type of module that is planned to be in-
stalled in the slot. If a DS3 Module is installed, the
T
YPE
field automatically defaults to
DS3. This field can also
be used to preconfigure a system before installing mod-
ules by specifying the module that is to be installed into
each slot.
NOTE
If a module is installed,
T
YPE
automatically
displays the name of the installed module. To
change this name, remove the installed mod-
ule, set
T
YPE
to E
MPTY
and then select another
module.
M
ENU
Displays additional status and configuration menus for
the selected module. To access the submenus for this
item, use the arrow keys to scroll to the
M
ENU
column
for the module to be edited, then press
Enter
. For
detailed information on each submenu item, see DS3
Module Menu Options on page 6.
A
LARM
Read security: 5
Displays the alarm conditions on the DS3 Module.
Press
Enter
in this field to activate the A
LARM
menu. See
Rx Alarms on page 6.
T
EST
Read security: 5
Displays tests that the DS3 Module is executing. Press
Enter
in this field to activate the T
EST
menu.
S
TATE
Read security: 5; Write security: 3
Indicates the current state of the module, either
O
NLINE
or
O
FFLINE
. Even though a module may be physically
installed, it must be marked
O
NLINE
to be considered an
available resource. Marking an installed module
O
FFLINE
may be useful in system troubleshooting. If
O
FFLINE
is chosen, the module will not be in alarm con-
dition, but will display
O
FFLINE
.
6 61200333L1-5B
NOTE
A module must be in the online state for Total
Access 4303 to use the module for any data
bandwidth.
S
TATUS
Read security: 5
A read-only field that presents status information on the
DS3 Module. The following messages may display:
O
NLINE
The module is enabled and is responding to the sys-
tem controller’s status polls. This is the normal re-
sponse of the system.
N
O
R
ESPONSE
The module is enabled, but is not responding to the
system controller’s status polls. This response indi-
cates either a problem in the system or that the mod-
ule is not installed.
E
MPTY
The system controller has not detected the presence
of a module in the slot, nor has a module been man-
ually enabled for this option slot.
O
FFLINE
The module is installed, but has been taken offline
by a user. The module is still responding to control-
ler polls.
O
FFLINE
/N
O
R
ESPONSE
The module is installed, but has been taken offline
by a user. The module is not responding to controller
polls.
N
OT
S
UPPORTED
The slot contains a module that is not supported by
the current system configuration.
S
TANDBY
A redundant module in the standby state ready to as-
sume an active role if the online module should fail.
R
EV
Read security: 5
A read-only field that displays the hardware revision
(also known as “top assembly revision”) of the DS3
Module.
DS3 Module Menu Options
Figure 4 shows the DS3 Module menus. The following
sections describe the menu options:
DS3 I
NFO
, DS3
A
LARM
S
TATUS
, DS3 P
ERFORMANCE
: C
URR
, 15 M
IN
,
24 H
R
, DS3 C
ONFIGURATION
, DS3 T
EST
, DS1 A
LARM
S
TATUS
, DS1 DS0 S
TATUS
, DS1 DS0 A
LARMS
, DS1 S
IG
S
TATUS
, DS1 P
ERFORMANCE
: C
URR
, 15 M
IN
, 24 H
R
,
DS1 C
ONFIGURATION
, and
DS1 T
EST
.
Figure 4. Menu Options
DS3 I
NFO
Read security: 5
Displays information about the module.
P
ART
N
UMBER
Displays the part number of the module (read-only).
S
ERIAL
N
UMBER
Displays the serial number of the module (read-
only).
CLEI C
ODE
Displays the Common Language Equipment Identi-
fication Code for the module (read-only).
B
OARD
R
EVISION
Displays the PCB revision (read-only).
DS3 A
LARM
S
TATUS
Read security: 5
Displays the current DS3 alarm status including the port
number (
P
RT
), A
LARMS
, Far End Alarms (FE A
LARMS
),
and Receive Framing Alarms (
R
X
F
RAMING
).
P
RT
Displays the port number.
R
X
A
LARMS
Read security: 5
Displays an alarm condition on the DS3 interface of
the DS3 Module. Alarm conditions include Loss of
Signal (
LOS), Red Alarm (R
ED
), Yellow Alarm
61200333L1-5B 7
(Y
EL
), Blue Alarm (B
LUE
), Far End Alarms (FE
A
LARMS
), and RX Framing Alarm (C-B
IT
).
LOS - indicates no signal detected at DS3 port
interface
R
ED
- indicates inability to frame data received
on the DS3 port; also referred to as Out of Frame
(OOF) for 2.5 seconds
Y
EL
- receiving remote alarm (RAI) on port; far
end equipment is in Red Alarm (
R
ED
)
B
LUE
- receiving unframed all ones from the port
Alarm Indicator Signal (AIS) in payload from far
end equipment
FAR
E
ND
A
LARMS
Read security: 5; Write security: 3
Indicates the strength of the signal (in dB) received
on the port.
CBIT S
TATUS
(R
X
F
RAMING
)
Read security: 5; Write security: 3
Indicates reception of C-Bit parity framing.
DS3 P
ERF
C
URRENT
Read security: 5; Write security: 4
The performance fields provide status information on
key performance measures for the DS3 port. Except for
CLR, these fields are all read-only. The monitored pa-
rameters include the following:
PRT - Displays the port number
CLR - Clears performance information for the se-
lected port
ES_L (Errored Seconds - Line) - Count of seconds
containing excessive zeros, LOS, or BPVs, not due
to line code substitutions.
SES_L (Severely Errored Seconds - Line) - Count
of seconds containing excessive zeros, LOS, or
BPVs, not due to line code substitutions above a
predetermined threshold.
LOSS_L (Loss of Signal Second - Line) - Count of
seconds of LOS condition.
CV_P (Code Violation - Path) - For the M13 appli-
cation, an accumulation of P-bit parity errors. For
the C-bit parity application, an accumulation of CP-
bit parity errors.
ES_P (Errored Second - Path) - An accumulation of
seconds during which any one of the following con-
ditions exist: parity errors, severely errored frame,
or AIS signal received.
SAS_P (SEF/AIS Second) - An accumulation of
seconds during which severely errored frames or
AIS signal is received.
SES_P (Severely Errored Seconds - Path) - An ac-
cumulation of seconds during which parity errors,
severely errored frame, or AIS signal is received.
UAS_P (Unavailable Seconds - Path) - An accumu-
lation of one-second intervals during which the DS3
path is unavailable; i.e., 10 contiguous SES_Ps.
DS3 P
ERF
15 M
IN
Read security: 5; Write security: 4
Stores the performance data for the previous 15-minute
window. Refer back to DS3 Perf Current for a detailed
description of these fields.
DS3 P
ERF
24 H
R
Read security: 5; Write security: 4
See DS3 Perf 15 Min, but use 24-hour window instead
of 15-minute.
DS3 C
ONFIGURATION
All of the following configurable parameters apply
whether or not the port is connected to a channelized
DS3 circuit.
P
RT
Read security: 5
Displays the port number.
P
ORT
N
AME
Read security: 5; Write security: 3
Accepts any alphanumeric name up to 16 characters
long to uniquely identify each port on the DS3 Mod-
ule.
F
RAME
F
ORMAT
Read security: 5; Write security: 2
This field must be set to match the frame format of
the DS3 circuit. Choose either
CBIT or M13.
C
LOCK
S
OURCE
Read security: 5; Write security: 2
Controls the clocking used for the DS3 circuit clock.
Choose
R
ECOVERED
to use the clocking received on
the DS3 or
I
NTERNAL
to use the provided ±20 PPM
crystal source in the Total Access 4303.
LBO
Read security: 5; Write security: 2
Selects the Line Build Out (LBO) for the network in-
terface. When connecting a DS3 module port to a
DS3 interface, this parameter is set to match the dis-
tance (in feet) between the Total Access 4303 and
the device to which it is connecting. When this item
is selected, choose
S
HORT
for 0-50 feet and L
ONG
for
51-250 feet.
8 61200333L1-5B
DS3 T
EST
Read security: 5; Write security: 4
Initiates different types of tests and displays test results.
This menu includes the following submenus:
P
RT
,
L
OOPBACK
, R
EMOTE
LB, R
EMOTE
S
TATUS
.
NOTE
When activated, these test commands will tem-
porarily disrupt service.
P
RT
Read security: 5
Displays the port number.
L
OOPBACK
Read security: 5; Write security: 4
Cause line loopback (
L
INE
) on the near-end (local)
port (see Figure 5). Choose
L
INE
to activate the local
loopback.
Figure 5. Network Loopback Tests
R
EMOTE
LB
Read security: 5; Write security: 4
Sends loopback codes to remote CSU. The follow-
ing options are available:
DS3 L
INE
- Loops the remote (far-end) DS3 port
CSU
DS1 #N L
INE
(N = 1 through 24) - Loops the re-
mote (far-end) DS1 framer of the selected DS1
line
DS1 A
LL
L
INES
- Loops all the remote (far-end)
DS1 framers on the DS3 circuit
R
EMOTE
S
TATUS
Read security: 5
Displays the current test status of loopbacks.
DS1 A
LARM
S
TATUS
Read security: 5
Displays the current DS1 alarm status including the port
number (
P
RT
) and current alarms.
P
RT
Displays the port number.
T1 A
LARMS
Read security: 5
Displays an alarm condition on the DS1 circuit.
Alarm conditions include Red Alarm (
R
ED
), Yellow
Alarm (
Y
ELLOW
), Blue Alarm (
B
LUE
), and
DS0
A
LARM
.
R
ED
- indicates inability to frame data received
on the DS3 port; also referred to as Out of Frame
(OOF) for 2.5 seconds.
Y
ELLOW
- receiving remote alarm (RAI) on port;
far-end equipment is in Red Alarm (
R
ED
).
B
LUE
- receiving unframed all ones from the port
alarm indicator signal (AIS) in payload from far-
end equipment.
DS0 A
LARM
- indicates a DS0 Alarm (D Channel
Alarm, Frame Alarm, TBOP Alarm, or PPP
Alarm) on a channel.
DS1 DS0 S
TATUS
Read security: 5
The DS0 status indicates usage on a DS0 basis for each
port. These options are read-only.
DS3
DS1 Line and Payload
DS3 Line Loopback
DS3
Unallocated
Inactive
$
Active GR-303 call on this DS0
1
Dedicated DS0
(
Embedded Operations Channel (EOC)
7
Timeslot Management Channel (TMC)
;
GR-303 Cross-connect
61200333L1-5B 9
DS1 DS0 A
LARMS
Read security: 5
Displays a per-DS0 alarm status; these alarms usually
indicate a failure to receive the protocol that has been
configured for the DS0. The following results may dis-
play:
DS1 S
IG
S
TATUS
Read security: 5
A read-only field that indicates signaling of all 24 DS0s.
The A/B bits for Rx (receive) and Tx (transmit) DS0s
are shown for each port. Dashes display for those DS0s
where robbed bit signaling (RBS) is not being trans-
ferred by the Total Access 4303.
DS1 P
ERF
C
URRENT
Read security: 5; Write security: 4
The performance fields (either
C
URRENT
, 15 M
IN
, or
24 H
R
) provide status information on key performance
measures as specified in ANSI T1.403 and AT&T
TR54016 for each of the T1/DSX-1 ports. Except for
CLR, these fields are all read-only. The monitored pa-
rameters include the following:
P
RT
- Displays the port number
CLR - Clears performance information for the se-
lected port
ES - An ES (Errored Seconds) is a second with one
or more error events OR one or more OOF events
OR one or more Controlled Slip Seconds (CSS)
BES - A BES (Bursty Errored Seconds) is a second
with more than one, but less than 320 error events
SES - An SES (Severely Errored Seconds) is a sec-
ond with 320 or more error events OR one or more
OOF events
SEFS - Severely Errored Frame Seconds
LOFC - Loss of Frame Count
CSS - Controlled Slip Seconds
UAS - Unavailable Seconds
PCV - Path Code Violations
DS1 P
ERF
15 M
IN
Read security: 5; Write security: 4
Stores the performance data for the previous 15-minute
window. Refer back to DS1 Perf Current for a detailed
description of these fields.
DS1 P
ER
24 H
R
Read security: 5; Write security: 4
Stores the performance data for the previous 24-hour
window. Refer back to DS1 Perf Current for a detailed
description.
DS1 C
ONFIGURATION
All of the following configurable parameters apply
whether the port is connected to a channelized T1
circuit.
P
RT
Read security: 5
Displays the port number.
P
ORT
N
AME
Read security: 5; Write security: 3
Accepts any alphanumeric name up to 16 characters
long to uniquely identify each port on the DS3
Module.
F
RAME
F
ORMAT
Read security: 5; Write security: 3
This field must be set to match the frame format of
the circuit to which it is connected. Choose either
D4
or
ESF.
A
UTO
T
X
Y
ELLOW
A
LARM
Read security: 5; Write security: 3
Controls the transmitting of yellow alarms (Auto Tx
Yellow Alarm). Choose either
O
N
or O
FF
.
T
RANSMIT
PRM
S
Read security: 5; Write security: 3
Controls the sending (Tx) of Performance Report
Messaging (PRM) data on the Facility Data Link
(FDL). PRM data continues to be collected even if
XMIT PRM is turned off (possible only with ESF
format). Choose either
O
N
or O
FF
.
L
OOPBACK
A
CCEPT
Read security: 5; Write security: 3
Accepts or ignores loopback functionality.
R
EMOTE
M
ANAGEMENT
O
VER
FDL
Write security: 3; Read security: 5
Enables or disables remote management on the DS1
circuit. Remote Management provides a way to
monitor and configure compatible ADTRAN prod-
ucts located at the remote end of the circuit.
No DSO alarm
'
D Channel Alarm (ISDN)
)
Frame Alarm (PACKET)
7
TBOP Alarm (PACKET)
3
PPP Alarm (PACKET)
10 61200333L1-5B
DS1 T
EST
Read security: 5; Write security: 4
Initiates different types of tests and displays test re-
sults.
NOTE
When activated, these test commands will tem-
porarily disrupt service.
P
RT
Read security: 5
Displays the port number.
L
OCAL
L
OOPBACK
Read security: 5; Write security: 4
Causes line loopback (LB) on the near-end (local)
port (see Figure 5). The following options are avail-
able:
L
INE
- metallic loopback
P
AYLD
- payload loopback; regenerates framing
and clocking (see Figure 5)
R
EMOTE
L
OOPBACK
Read security: 5; Write security: 4
Sends loopback code to remote CSU. The following
options are available:
ATT I
NBAND
L
INE
- works in ESF and D4 mode
ANSI FDL L
INE
- requires ESF mode
ANSI FDL P
YLD
- requires ESF mode
T
EST
P
ATTERN
Read security: 5; Write security: 4
Indicates the active test pattern to be transmitted out
the port. The following options are available:
A
LL
ONES
- indicates framed ones
A
LL
ZEROS
- indicates framed zeros
QRSS - indicates a pseudo-random pattern with
suppression of excess zeros
QRSS/RLB R
ESULTS
Read security: 5; Write security: 4
Displays current T1 test status including loopbacks
and test patterns by indicating sync patterns (
N
ONE
,
LOS, S
YNC
) and an errored seconds count (ES) for
the received pattern.
QRSS P
ATTERN
R
ESULTS
C
LEAR
Read security: 5; Write security: 4
Clears error counters on test pattern results menu.
QRSS P
ATTERN
E
RROR
I
NJECT
Read security: 5; Write security: 45
Injects errors into transmitted test pattern.
R
EDUNDANCY
Read security: 5; Write security: 5
The
R
EDUNDANCY
submenu items are explained below.
M
ODULE
R
EDUNDANCY
Read security: 5; Write security: 3
The field choices are
D
ISABLED
and E
NABLED
.
E
RROR
T
HRESHOLD
Read security: 5; Write security: 3
The field choices are Disabled and
1E-03, 1E-04,
1E-05, and 1E-06.
M
INIMUM
S
WITCH
T
IME
Read security: 5; Write security: 3
This field is used to set the minimum switch time.
S
WITCH
C
OUNT
Read security: 5
This field displays the number of times that the mod-
ule switch has occurred.
C
LEAR
S
WITCH
C
OUNT
<+>
Read security: 5; Write security: 3
This command is used to reset the number of times
that a module switch has occurred.
F
ORCE
S
WITCHOVER
<+>
Read security: 5; Write security: 3
This command forces a redundancy switch to a
standby module.
Run Self-Test
Read security: 5; Write security: 3
To run a self-test on the module, go to the
S
YSTEM
U
TILITY
menu, select S
YSTEM
S
ELFTEST
, and set the
S
ELFTEST
field to R
UN
. This menu allows individual
self-tests to be run on all modules.
Mapping
Cross-connects are defined in the
D
EDICATED
M
APS
or in
the
GR-303 RT for GR-303 applications. See the Total
Access 4303 System Manual (Section 5, User Interface
Guide) for a description of these menus.
61200333L1-5B 11
4. MAINTENANCE
The DS3 Module requires no routine maintenance to
operate properly.
ADTRAN does not recommend that repairs be
performed in the field. Repair services may be obtained
by returning the defective unit to ADTRAN. Refer to
the Warranty and Customer Service section for further
information.
5. SPECIFICATIONS
Specifications for the Total Access 4303 DS3 Module
are detailed in Table 3. Each port of the DS3 Module
conforms to the following specifications:
6. WARRANTY AND CUSTOMER SERVICE
ADTRAN will replace or repair this product within ten
(10) years from the date of shipment if it does not meet
its published specifications or fails while in service.
Refer to ADTRAN U.S. and Canada Carrier Networks
Equipment Warranty, Document 60000087-10.
Contact Customer and Product Service (CAPS) prior to
returning equipment to ADTRAN.
For service, CAPS requests, or further information,
contact one of the following numbers:
ADTRAN Sales
Pricing/Availability
(800) 827-0807
ADTRAN Technical Support
Pre-sales Applications/Post-sales Technical Assistance
(800) 726-8663
Standard hours: Monday-Friday, 7 a.m. - 7 p.m. CST
Emergency hours: 7 days/week, 24 hours/day
ADTRAN Repair/CAPS
Return for Repair/Upgrade
(256) 963-8722
Repair and Return Address
ADTRAN, Inc.
CAPS Department
901 Explorer Boulevard
Huntsville, Alabama 35806-2807
12 61200333L1-5B
Table 3: DS3 Module Specifications
3HUIRUPDQFH
&DSDFLW\
)UDPLQJ
/LQH%XLOG2XW
/LQH&RGLQJ
/LQH5DWH
7HUPLQDWLQJ,PSHGDQFH
'6'6V'6V
0RU&ELWSDULW\
WRIHHW6KRUW
WRIHHW/RQJ
%=6ELSRODU]HURVXEVWLWXWLRQ
0ESV
ESV
RKPV
XQEDODQFHG
3K\VLFDO
'LPHQVLRQV
:HLJKW
LQ+[LQ:[LQ'
OEV
3RZHU
&XUUHQW'UDZ $PD[LPXPDW9'&
(QYLURQPHQWDO
2SHUDWLQJ7HPSHUDWXUH6WDQGDUG
6WRUDJH7HPSHUDWXUH
5HODWLYH+XPLGLW\
+HDW'LVVLSDWLRQ
&WS&
&WR&
PD[LPXPQRQFRQGHQVLQJ
ZDWWVPD[LPXP
&RPSOLDQFH
)&&3DUW
8/
$16,7$16,7$77DQG$77
1(%6/HYHO
3DUW1XPEHU
7RWDO$FFHVV'60RGXOH /
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

ADTRAN TOTAL ACCESS 4303 DS3 Installation and Maintenance

Type
Installation and Maintenance

ADTRAN TOTAL ACCESS 4303 DS3 combines with the Total Access 4303 base unit and other Total Access 4303 modules to support requirements calling for multiple DSX-1 circuits. It includes extensive performance monitoring of the DS3 or individual DS1 circuits, inherent DACS capability, and compliance with ANSI T1.102, ANSI T1.403, AT&T 54016, and AT&T 62411. Provisioned by software only, the device does not require any hardware switches, and it offers local and remote line and payload loopbacks as well as QRSS test pattern available per port.