Chauvet Professional Epix Strip IP 50 Reference guide

Type
Reference guide

This manual is also suitable for

Quick Reference Guide
English EN
Español ES
Français FR
Nederlands NL
1
EN
QUICK REFERENCE GUIDE
EPIX Strip IP 50 QRG Rev. 2
About This Guide
The EPIX Strip IP 50 Quick Reference Guide (QRG) has basic product information such as connection and mounting.
Download the ÉPIX Drive 2000 IP User Manual from www.chauvetprofessional.com
for more details.
Disclaimer
The information and specifications contained in this QRG are subject to change without notice.
LIMITED WARRANTY
FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE.
For Customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration
.
For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and
Germany: www.chauvetlighting.eu/warranty-registration
.
Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the
period specified in, and subject to the exclusions and limitations set forth in the full limited warranty on our website. This
warranty extends only to the original purchaser of the product and is not transferable. To exercise rights under this
warranty, you must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows
the product name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. This
warranty gives you specific legal rights. You may also have other rights that vary from state to state and country to
country. This warranty is valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands,
Luxembourg, France, Germany and Mexico. For warranty terms in other countries, please consult your local distributor.
Safety Notes
These Safety Notes include important information about installation, use, and maintenance.
DO NOT open this product. It contains no user-serviceable parts.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
CAUTION: This product’s housing may be hot when lights are operating.
CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to warm humid
ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow
product to fully acclimate to the surrounding environment before connecting it to power.
CAUTION: This product’s housing may be hot when lights are operating.
Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
DO NOT leave any flammable material within 50 cm of this product while operating or connected to power.
USE a safety cable when mounting this product overhead.
DO NOT submerge this product (IP65). Temporary outdoor operation is fine.
When using this product in an outdoor environment, use IP65 (or higher) rated power and data cables. Be sure to
secure unused power and data ports with attached IP65 covers.
DO NOT operate this product if the housing, ports, or cables appear damaged.
DO NOT connect this product to a dimmer or rheostat.
ONLY connect this product to an ÉPIX Drive 2000 IP or ÉPIX Drive 900.
Only use the hanging/mounting bracket to carry this product.
In the event of a serious operating problem, stop using immediately.
The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.
Contact
Outside the U.S., United Kingdom, Ireland, Benelux, France, Germany, or Mexico, contact your distributor to request
support or return a product. Refer to Contact Us
at the end of this QRG for contact information.
What is Included
EPIX Strip IP 50
Square Milky Filter (Installed)
Black Stealth Filter
Round Milky Filter
Quick Reference Guide
EN
2
EPIX Strip IP 50 QRG Rev. 2
QUICK REFERENCE GUIDE
Product Overview
Product Dimensions
Data/Power
Interlocking
Hardware
Mounting Bracket
Fastening Knob/
Safety Loop
Data/Power
Filter
19.68 in
500 mm
2.32 in
59 mm
5.04 in
128 mm
3.66 in
93 mm
3.78 in
96 mm
1.38 in
35 mm
1.33 in
34 mm
3.94 in
100 mm
1.89 in
48 mm
3
EN
QUICK REFERENCE GUIDE
EPIX Strip IP 50 QRG Rev. 2
Power
This product is powered by an ÉPIX Drive 2000 IP or ÉPIX Drive 900. Refer to the ÉPIX Drive 2000 IP/900 User Manuals
for detailed instructions on how to connect this product to power.
Power Linking
You can link up to 20 EPIX Strip IP 50 products to each port of an ÉPIX Drive 2000 IP. Never exceed this number.
Scrambled Pulse-Width Modulation
This product features Scrambled-PWM (S-PWM) technology, which de-synchronizes the pulse widths of each color of the
multi-color LEDs. This ensures that there is always some LED output, reducing flicker, and maintaining the same
grayscale performance.
Filter Installation
The EPIX Strip IP 50 includes a Square Milky Filter already installed. Follow the procedure below to install the included
Black Stealth Filter or Round Milky Filter.
1. Locate the end cap of the product that does not have the interlocking hardware.
2. Push in on the end-cap latch.
3. Slide the installed filter out and replace it with the desired filter.
4. Release the end-cap latch.
Use ONLY IP65 4-pin XLR cables with the EPIX Strip IP 50. For our CHAUVET Professional line
of IP65 4-pin XLR cables, go to https://www.chauvetprofessional.com/accessories
.
To eliminate wear and improve its lifespan, during periods of non-use completely disconnect
the ÉPIX Drive 2000 IP from power via breaker or by unplugging it.
!
Interlocking Hardware
End-Cap Latch
EN
4
EPIX Strip IP 50 QRG Rev. 2
QUICK REFERENCE GUIDE
Mounting
Before mounting this product, read the Safety Notes. Use at least one mounting point per product. Make sure the
mounting clamps are capable of supporting the weight of the product. For our CHAUVET Professional line of mounting
clamps, go to http://trusst.com/products
.
Mounting Diagram
Safety Cable
Safety Loop
Eye Bolts
Mounting Clamp
5
EN
QUICK REFERENCE GUIDE
EPIX Strip IP 50 QRG Rev. 2
Vertical Mounting Instructions
1. Attach the clamp to the mounting bracket.
2. Attach the clamp to the desired structure or surface.
3. Attach a safety cable to the product’s safety loop.
Never attach more than 6 products together when hanging vertically from a single mounting point.
Attach the Safety Cable
of the first product to
the mounting point
Attach the Safety Cable of the
following products to the
Bracket of the preceding product
!
EN
6
EPIX Strip IP 50 QRG Rev. 2
QUICK REFERENCE GUIDE
Series Attachment Instructions
The EPIX Strip IP 50 can be attached in an end to end formation to create a strip up to 4 meters long from one mounting
point. Do not connect any more than 6 EPIX Strip IP 50 products in a row when hanging vertically.
1. Loosen the 2 fastening eye bolts.
2. Slide the connecting bracket out until it stops and tighten the eye bolt closest to the center of the product.
3. Slide the second EPIX Strip IP 50 into the connecting bracket and tighten the remaining eye bolt.
4. Attach the safety cable as shown in Vertical Mounting Instructions
.
Install the safety cable last when attaching EPIX Strip IP 50 products in series.
1
3
2
7
EN
QUICK REFERENCE GUIDE
EPIX Strip IP 50 QRG Rev. 2
Technical Specifications
Dimensions and Weight
Note: Dimensions in inches are rounded.
Power
Light Source
Photometrics
Control
Thermal
Ordering
Filter Length Width Height Weight
Square Milky Filter 19.68 in (500 mm) 1.33 in (34 mm) 3.93 in (100 mm) 3.4 lb (1.5 kg)
Black Stealth Filter 19.68 in (500 mm) 1.33 in (34 mm) 3.46 in (88 mm) 3.4 lb (1.5 kg)
Round Milky Filter 19.68 in (500 mm) 1.77 in (45 mm) 5.03 in (128 mm) 3.4 lb (1.5 kg)
Power Supply Range Power Linking
ÉPIX Drive 2000 IP 100 to 240 VAC, 50/60 Hz 20 per ÉPIX Drive 2000 IP port
Parameter 120 V, 60 Hz 208 V, 60 Hz 230 V, 50 Hz
Consumption 16 W 17 W 17 W
Operation Current 0.133 A 0.082 A 0.073 A
Power I/O U.S./Worldwide UK/Europe
Power Input Connector IP65 4-pin XLR IP65 4-pin XLR
Power Cord Plug IP65 4-pin XLR IP65 4-pin XLR
Type Color Quantity Lifespan
SMD 505 LED Tri-color RGB 50 50,000 hours
Parameter Square Milky Filter Black Stealth Filter Round Milky Filter
Viewing Angle 160° 125° 160°
Illuminance 2,470 NITS 1,455 NITS 1,360 NITS
Pixel Pitch 10 mm 10 mm 10 mm
Refresh Rate 4,800 Hz 4,800 Hz 4,800 Hz
Data I/O Channel Range (Art-Net™/sACN) Channel Range (Kling-Net)
IP65 4-pin XLR 7, 15, 30, 75, or 150
Determined by ArKaos MediaMaster
software
Maximum External Temp. Cooling
113 °F (45 °C) Convection
Product Name Item Name Item Code UPC Number
EPIX Strip IP 50 EPIXSTRIPIP 03091435 781462217839
23
NL
BEKNOPTE HANDLEIDING
EPIX Strip IP 50 QRG Rev. 2
Productbeschrijving
Productafmetingen
Filter
Gegevens/stroom-ingang
Verbindende
apparatuur
Montagebeugel
Bevestigingsknop
/veiligheidslus
Gegevens/stroom-uitgang
19.68 in
500 mm
2.32 in
59 mm
5.04 in
128 mm
3.66 in
93 mm
3.78 in
96 mm
1.38 in
35 mm
1.33 in
34 mm
3.94 in
100 mm
1.89 in
48 mm
Multi-Language
QUICK REFERENCE GUIDE
27
EPIX Strip IP 50 QRG Rev. 2
Contact Us
Visit the applicable website above to verify our contact information and instructions to request support. Outside the
U.S., United Kingdom, Ireland, Mexico, France, Germany, or Benelux, contact the dealer of record.
General Information Technical Support
Chauvet World Headquarters
Address: 5200 NW 108th Ave. Voice: (844) 393-7575
Sunrise, FL 33351 Fax: (954) 756-8015
Voice: (954) 577-4455 Email: chauvetcs@chauvetlighting.com
Fax: (954) 929-5560
Toll Free: (800) 762-1084 Website: www.chauvetprofessional.com
Chauvet Europe Ltd.
Address: Unit 1C Email: [email protected]
Brookhill Road Industrial Estate
Pinxton, Nottingham, UK Website: www.chauvetprofessional.eu
NG16 6NT
Voice: +44 (0) 1773 511115
Fax: +44 (0) 1773 511110
Chauvet Europe BVBA
Address: Stokstraat 18 Email: BNLtec[email protected]
9770 Kruishoutem
Belgium Website: www.chauvetprofessional.eu
Voice: +32 9 388 93 97
Chauvet France
Address: 3, Rue Ampère
91380 Chilly-Mazarin
France Website: www.chauvetprofessional.eu
Voice: +33 1 78 85 33 59
Chauvet Germany
Address: Bruno-Bürgel-Str. 11
28759 Bremen
Email: DEtech@chauvetlighting.de
Germany Website: www.chauvetprofessional.eu
Voice: +49 421 62 60 20
Chauvet Mexico
Address: Av. de las Partidas 34 - 3B
(Entrance by Calle 2)
Zona Industrial Lerma Website: www.chauvetprofessional.mx
Lerma, Edo. de México, CP 52000
Voice: +52 (728) 690-2010
UL 1573
CSA C22.2 No. 166
E113093
R
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Chauvet Professional Epix Strip IP 50 Reference guide

Type
Reference guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI