Extech Instruments AUT35 User manual

Category
Measuring, testing & control
Type
User manual
USER GUIDE
AUT35-EU-EN V1.0 07/13
ModelAUT35
30AAutomotive
CurrentTester
Features
LargedigitLCDdisplaywithbargraphindication
ForusewithminibladeandATCbladesizefuses
Includesminiblade,ATCblade,and‘alligator’clamp
connectorswith1.3ft.(40cm)cable
Measuringrangeto30A/48VDC(10sec.testtimemax.)
Safety
WARNING:RiskofElectrocution.Keephandsandfingersonthe
bodyoftheprobeandawayfromthebladetips.
CAUTION:Read,understandandfollowSafetyRulesand
OperatingInstructionsinthismanualbeforeusingmeter.
Donotattempttorepairthisunit.Therearenouserserviceable
parts.
Do
notexposeunittoextremetemperatures/highhumidity
Donotusetheunitifitiswetordamaged
Donotapplymorethantheratedvoltagebetweentheprobetip
andground.
Donotoperatewiththecaseopen
Thissymbol,adjacenttoanothersymbolorterminal,
indicatestheusertheusermustrefertothemanual
forfurtherinformation.
Thissymbol,adjacenttoaterminal,indicatesthat,
undernormaluse,hazardousvoltagesmaybepresent
Doubleinsulation
Copyright©2013FLIRSystems,Inc.
Allrightsreservedincludingtherightofreproductioninwholeorinpartinanyform
www.extech.com
Specifications
Range0to30ADC/48VDC
Resolution100mA
Accuracy±(2%ofreading+2digits)
Detectiondistance <0.2”
OperatingTemperature 0to50
o
C(32to122
o
F)
StorageTemperature 20to60
o
C(4to140
o
F)
Altitude2000m(7000ft.)maximum
RelativeHumidity 80%to31
o
C,decreasingto50%at
50
o
C
Battery1x9Vbattery
DimensionsandWeight86x37x28mm(3.4x1.5x1.1")
68g(0.15lbs.)
OperatingInstructions
1. Determineconnectiontype:blades(7)oralligatorclamps(8).
2. Connectthedesiredtestcabletothemetersbananajack
connectorcable(6),redtored,blacktoblack.
3. TurnthevehicleignitionOFF.
4. Iftestingthroughthevehiclefusebox:a.Removethefusefor
the
circuitundertest;b.Plugtheblade(7)intothefusebox
(wherethefusewasremoved);andc.Inserttheremoved
fuseintothefusejackonthemeasurementcable(9).
5. Ifusingalligatorclampsconnecttheblackclampontoagood
groundandconnectredclamptothe
positivetestpoint.
6. Befor econ tinuingpleasenotethattestsshouldbelimitedto
a10secondperiod.Longertestscoulddamagethemeter.
7. PressthemetersPowerbutton(5)toswitchitON.
8. PresstheZERObutton(3)tozerothedisplayed reading.
9. Powerthecircuitunder
testupto10secondsonlyandread
theLCDbargraph(1)andthedisplaydigits(2)forthe
measuredDCcurrent.
10. UsetheHOLDbutton(4)tofreezethedisplayedreading.
11. WhenfinishedpressPowertoswitchthemeterOFF.
12. WARNING! The Fuse blades or Alligat or
clamp may become
hotduringtesting.Allowtocoolbeforeremoving.Donottest
>10seconds.
BatteryInstallation
1. Toreplacethebattery,removethescrewfromthebackofthe
unitandremovethecover.
2. Insertorreplacethe9Vbattery(observepolarity).
3. Replacethebatterycover.
Neverdisposeofusedbatteriesorrechargeable
batteriesinhouseholdwaste.
Asconsumers,usersarelegallyrequiredtotakeused
batteriestoappropriatecollectionsites,theretail
storewherethebatterieswerepurchased,or
whereverbatteriesaresold.
Disposal: Do not dispose of this instrument in house h old waste. The
user is
obligated to take endoflifedevicesto a designatedcollection
pointforthedisposalofelectricalandelectronicequipment.
Warranty
FLIR Systems, Inc.warrantsthis ExtechInstruments brand deviceto be free of
defects in parts and workmanship for one year from date of shipment (a six
month limited warranty applies to sensors and cables). If it should become
necessary to return the instrument for service during or beyond the warranty
period, contact the Customer Service Department for authorization. Visit the
website www.extech.com for contact information. A Return Authorization (RA)
numbermustbeissuedbeforeanyproductisreturned.Thesenderisresponsible
forshippingcharges,freight,insuranceandproperpackagingtopreventdamage
in transit. This warranty does not apply to defects resulting from action of the
user such as misuse, improper wiring, operation outside of specification,
impropermaintenanceor
repair,orunauthorizedmodification.FLIRSystems,Inc.
specifically disclaims any implied warranties or merchantability or fitness for a
specific purpose and will not be liable for any direct, indirect, incidental or
consequentialdamages.FLIR’stotalliabilityislimitedtorepairorreplacementof
the product. The warranty set forth above
is inclusive and no other warranty,
whetherwrittenororal,isexpressedorimplied.
Calibration,Repair,andCustomerCare
FLIR Systems, Inc. offers repair and calibration services for the Extech
Instruments products we sell. NIST certification for most products is also
provided. Call the Customer Service Department for information on cali bration
services available for this product. Annual calibrations should be performed to
verifymeterperformanceandaccuracy.Technicalsupportand
generalcustomer
serviceisalsoprovided,ref ertothecontactinformationprovidedbelow.
SupportLines:U.S.(877)4398324
International:+1(603)3247800
TechnicalSupport:Option3;Email:[email protected]
Repair&Returns:Option4;Email:repair@extech.com
Productspecificationsaresubjecttochangewithoutnotice
Pleasevisitourwebsiteforthemostuptodateinformation
www.extech.com
FLIRCommercialSystems,Inc.,9Townse ndWest,Nashua,NH03063USA
ISO9001Certified
  • Page 1 1

Extech Instruments AUT35 User manual

Category
Measuring, testing & control
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI