USER GUIDE
AUTTL/AUTTLM-EU-EN V1.1 07/13
ModelAUT‐TL/AUT‐TLM
AutomotiveFuseAdaptor
Features
• 80cm(2.6ft.)connectorcablewithstandard shrouded
rightanglebananaplugs(1)
• Bladeconnector(3)
• Fusejack(2)
• Measuringrangeupto20A/48VDC
• TheAUT‐TLworkswiththeATCsizedfuses,whereasthe
AUT‐TLMworkswithmini‐sizedfuses.
Safety
WARNING:RiskofElectrocution.Keephandsandfingerson
thebodyoftheconnectorandawayfromtheprobetips
CAUTION:Read,understandandfollowSafetyRulesand
OperatingInstructionsinthismanualbeforeusingthis
product.
Donotattempttorepairthisunit.Therearenouser
serviceableparts.
Donotexposetheunittoextremetemperaturesorhigh
humidity
Donotusetheunitifitiswetordamaged
Donotapplymorethantheratedvoltagetotheconnector
Thissymbol,adjacenttoanothersymbolorterminal,
indicatestheusertheusermustrefertothe
manual
forfurtherinformation.
Thissymbol,adjacenttoaterminal,indicatesthat,
undernormaluse,hazardousvoltagesmaybepresent
Doubleinsulation
Specifications
Range 0to20A,48VDC
OperatingTemp. 0to50
o
C(32to122
o
F)
StorageTemp. ‐20to60
o
C(‐4to140
o
F)
Altitude 2000m(7000ft.)maximum
RelativeHumidity 80%upto31
o
C,decreasingto50%at50
o
C
Dimensions 112x45x33mm(4.4”x1.8”x1.3")
Weight 165g(0.4lbs)
Resolution 0.1A
OperatingInstructions
The AUT‐TL / AUT‐TLM in combination with a standard
Multimeterallowstheusertocheckautomotivecurrentupto
20Awithoutbreakingthecircuit.
1. Connectthetwoshroudedright‐anglebananajacktest
leads(1)toanyMultimeterthatoffersa20Acurrent
input.
2. Ensurethatthe
vehicle’signitionisintheOFFposition.
3. Removethe fuseorminifuseforthecircuitundertest
fromthevehicle’sfuseboxandcarefullysetitaside.
4. Plugthebladeconnector(3)directlyintothefusebox
jackwherethefusewasremoved.
5. Connecttheremovedfusetothefusejack(2)onthe
sideoftheconnector.
6. Turnthevehicle’ signitionONandrunthecircuitunder
testfor10secondsmaximum.
7. ReadthecurrentvalueontheMultimeter’sdisplay.
Warranty
FLIR Systems, Inc. warrants this Extech Instruments brand device to be free of
defects in parts and workmanship for one year from date of shipment (a six
month limited warranty applies to sensors and cables). If it should become
necessary to return the instrument for service during or beyond the warranty
period, contact the Customer Service Department for authorization. Visit the
website www.extech.com for contact information. A Return Authorization (RA)
numbermustbeissuedbeforeanyproductisreturned.Thesenderisresponsible
forshippingcharges,freight,insuranceandproperpackagingtopreventdamage
in transit. This warranty does not apply to defects resulting from action of the
user such as misuse, improper wiring, operation outside of specification,
impropermaintenanceor
repair,orunauthorizedmodification.FLIRSystems,Inc.
specifically disclaims any implied warranties or merchantability or fitness for a
specific purpose and will not be liable for any direct, indirect, incidental or
consequentialdamages.FLIR’stotalliabilityislimitedtorepairorreplacementof
the product. The warranty set forth above
is inclusive and no other warranty,
whetherwrittenororal,isexpressedorimplied.
Calibration,Repair,&CustomerCare
FLIR Systems, Inc. offers repair and calibration services for the Extech
Instruments products we sell. NIST certification for most products is also
provided. Call the Customer Service Department for information on calibration
services available for this product. Annual calibrations should be performed to
verifymeterperformanceandaccuracy.Technicalsupportand
generalcustomer
serviceisalsoprovided,ref ertothecontactinformationprovidedbelow.
Copyright©2013FLIRSystems,Inc.
Allrightsreservedincludingtherightofreproductioninwholeorinpartinanyform
www.extech.com
Support Lines:U.S.(877)439‐8324
International:+1(603)324‐7800
Repair&Returns:Option4;E‐mail:repair@extech.com
Productspecificationsaresubjecttochangewithoutnotice
Pleasevisitourwebsiteforthemostup‐to‐dateinformation
www.extech.com
FLIRCommercialSystems,Inc.,9TownsendWest,Nashua,NH03063USA
ISO9001Certified