  • Hello! I am an AI chatbot trained to assist you with the Danfoss K08106 MS Connector Assembly Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
THREADED
COLLAR
BODY
GROMMET
INSERT
BACK SHELL
SHELL
FACE SEAL
CONTACT
SOCKETS
STRAIN RELIEF CLAMP
MS Connector Part Number SG3108E-14S-2S-SR
(Sauer- Danfoss Part Number K08106)
1. Disassemble the shell from the body (leave the threaded
collar on the shell) and disassemble the clamp from the
body.
2. Insert four lead wires through the clamp, the insert, the
grommet, the body, and the threaded collar. Note, all
four holes of the grommet must be filled—use a section
of lead wire to fill unused holes as applicable.
3. Strip lead wire ends 5/16-inch and tin.
4. Solder lead wires to appropriate solder cups.
5. Assemble body to shell (with threaded collar in place).
Note desired shell orientation.
6. Slide grommet up to body and place insert over grommet.
7. Assemble and tighten back shell to provide seal.
8. Assemble strain relief clamp.
9. Assemble connector and lead wire assembly to matching
connector. Wire tie lead wires to machine frame adjacent
to connection to provide strain relief.
Unit Specification
MS Connector Assembly Instructions
ASSEMBLY INSTRUCTIONS
2007
© Danfoss, 2013
K21484 Rev AB • September 2013