Z-Wave VRP03-1LW Owner's manual

Type
Owner's manual
NOTES:
• Ifusinganon-LevitonProgrammer/Remote,
refertotheProgrammer/Remoteinstruction
sheetforIncludingadevice.
• IfusingtheVRCPG'sInstallChecklistfeature,
godirectlytoStepB.
A)IfusingaLevitonZ-Wave
®
Programmer/
Remote,Cat.No.VRCPG,presstheMenu
buttonandscrolldowntoSystemSetup.Press
thecenterbuttontoselectSystemSetup
Menu.ChooseAdvancedSettings.Pressthe
centerbuttontoselectNetwork.
Scene Capable Plug-In Lamp Dimming Module
Cat. No. VRP
Ø
3-1LW
Rated:120VAC,60Hz
Incandescent:300Wmax.,14Wmin.
INSTALLATION INSTRUCTIONS
DI-000-VRP03-02A
INTRODUCTION
Leviton’sViziaRF+
TM
componentsare
designedtocommunicatewitheachother
viaRadioFrequency(RF)toprovideremote
controlofyourlighting.UsingRFtechnology
allowsLevitontoprovidethegreatestsignal
integritypossible.EachmoduleinLeviton’s
ViziaRF+
TM
componentlineisaZ-Wave
®
enableddevice.InaZ-Wave
®
network,each
deviceisdesignedtoactasarouter.These
routerswillre-transmittheRFsignalfromone
devicetoanotheruntiltheintendeddevice
isreached.Thisensuresthatthesignalis
receivedbyitsintendeddevicebyrouting
thesignalaroundobstaclesandradiodead
spots.TheSceneCapablePlug-inLamp
DimmingModuleiscompatiblewithany
Z-Wave
®
enablednetwork,regardlessofthe
manufacturerandcanalsobeusedwithother
devicesdisplayingtheZ-Wave
®
logo.
CAUTION:
Remembertoexercisegoodcommonsense
whenusingtheTimerfeaturesofyourremote,
especiallywhenschedulingunattended
devices.Therecanbesomeunexpected
consequencesifnotusedwithcare.For
example,anemptycoffeepotcanberemotely
turnedon.Ifthatshouldhappen,yourcoffee
potcouldbedamagedfromoverheating.Ifan
electricheateristurnedonbyremotecontrol
whileclothingisdrapedoverit,arecould
result.DO NOT USEtheremoteforthecontrol
ofhighpowerheatingappliancessuchas
portableheaters.Thisdevicewillnotcontrol
lightingthatisusedwithelectroniclow-voltage
andhighfrequencypowersupplytransformers,
norhighpressuredischargelamps(HID
lighting).Thisincludesmercury-vapor,sodium
vaporandmetalhalidelamps.DO NOT
changelocationafterunitisenrolledinZ-wave
®
network.
Including Scene Capable
Plug-In Lamp Dimming Module
into Z-Wave
®
Network:
Step 3
Attaching Scene Capable
Plug-In Lamp Dimming
Module to Wall Receptacle:
Step 2
• PlugthePlug-inDimmerModuleintowall
receptacle.Verifythatreceptacleislive.If
controlledbyawallswitch,theswitch
must be kept ONatalltimes.
Attaching Load to Scene
Capable Plug-In Lamp
Dimming Module:
Step 1
NOTE:InordertouseyourViziaRF+
TM
Scene
CapableLampDimmingModuleinaZ-Wave
®
network,itmustbeIncludedintothenetwork
usingaPrimaryProgrammer/Remote,suchas
Leviton’sCat.No.,VRCPG.BeforeIncludingyour
module,pleaserefertothePrimaryProgrammer/
Remoteinstructionsheetforcomplete
information.Refer to Step 3 for further details.
• LocatelamptobecontrolledbyScene
CapablePlug-InLampDimmingModuleand
ensureitisfullyoperational.Attachlampplug
intomodulereceptaclenotingproperpolarityof
blades.
NOTE:UsecheckboxeswhenStepsare
completed.
INSTALLING YOUR DIMMING MODULE
B)Whilestandingclosetothemodule
(approximately2-5ft.),pressthecenter
buttonto<Include>deviceinthenetwork.
NOTE:Onlyonedevicemaybeincluded
atatime.DO NOTputmultipledevicesinto
theInclusionmodeatanytime.
C)WhiletheProgrammer/Remoteisinthe
InclusionmodeandtheLEDisONonthe
SceneCapablePlug-InLampDimming
Module,presstheON/OFFbuttononthe
module.TheProgrammer/Remotewillverify
inclusionandtheLEDwillturnOFFonthe
SceneCapablePlug-InLampDimming
Module.
IftheSceneCapablePlug-InLamp
DimmingModuleisashingAmberwhile
intheInclusionmode,theProgrammer/
Remoteisstilltryingtocommunicatewith
theSceneCapablePlug-InLampDimming
Module.Waituntilthedevicestopsashing,
thenpressON/OFFbutton.
NOTE:IftheLEDontheSceneCapable
Plug-InLampDimmingModuleturns
solidRedwhileincluding,therehas
beenacommunicationerror.Refer to
Troubleshooting section.
D)ThePrimaryProgrammer/Remotewill
assignanodeIDnumber(Name)forthis
module.
NOTE:ThisIDnumber(Name)willbe
storedinthecontrollertobeusedforfuture
reference.
NOTE:Youmaynameoreditthenodeof
thisdeviceatthistime.
E)The module is now installed in the
network.
NOTE:Ifthemodulehasbeensuccessfully
Includedinthenetworkandtheusertriesto
Includeitagainwithout
rstexcludingitfromthe
network,themodulewill
retaintherstnodeIDit
hadreceivedandignore
thesecond.
WARNINGS AND CAUTIONS:
• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.
• Ifyouareunsureaboutanypartoftheseinstructions,consultaqualiedelectrician.
• Toreducetheriskofoverheatingandpossibledamagetootherequipmentdonotinstalltocontrola
motor-operatedappliance,uorescentlightingxture,oratransformersuppliedappliance.
WARNINGS AND CAUTIONS:
• Unplugunitwhenservicingconnectedlightingxtures.
• Savethisinstructionsheet.Itcontainsimportanttechnicaldataalongwithtesting
andtroubleshootinginformationwhichwillbeusefulafterinstallationiscomplete.
• SoftfadeON/OFF
• Scenecapable
• ON/OFFLED
• Twowaycommunication
• ManualONcapabilityatload
• RFreliability
• Easeofinstallation–Nonewwiring
• CompatiblewithotherZ-Wave
®
enableddevices
FEATURES
Step 2 cont’d Step 3 cont’d
Programming and
ON/OFF Button
1 ON
2 ON
3 ON
4 ON
OFF
OFF
OFF
OFF
Programmer/Remote
Cat. No. VRCPG
Center Button
Menu Button
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
LevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenetofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforveyearsfromthe
purchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuchveyearperiodtheproductisreturnedprepaid,withproofofpurchasedate,andadescriptionoftheproblemtoLeviton
Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591.Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthisproductorreinstallation.
Thiswarranty isvoidif thisproduct isinstalledimproperly orin animproperenvironment, overloaded,misused, opened,abused, oralteredin anymanner,or isnot usedundernormal operatingconditions ornotinaccordancewith any
labelsorinstructions.There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuch
implied warranty, including merchantability and tnessforaparticular purpose, is limited to ve years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or
loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.
OPERATION
NOTE: Forcompletedetailsonoperatingthe
PrimaryProgrammer/Remote,refertothe
individualdevice’sinstructionguide.
ON:ThiscommandwillBRIGHTENthelightsto
thelastlevelset.
OFF:ThiscommandwillDIMthelightstoOFF.
BRIGHTEN:ThiscommandwillBRIGHTENthe
lightstothedesiredlevel.
DIM:ThiscommandwillDIMthelightstothe
desiredlevel.
MANUAL ON:IfSceneCapablePlug-InLamp
DimmingModuleisOFF,turntheswitchlocated
onthecontrolledlampOFFforafewseconds,
thenONagain.Themodulewillturnthelamp
ONtofullBRIGHT.Thisprocedurecanbe
usedtoturnONthelampwithoutaccessingthe
transmitter.
NOTE:Ifapowerinterruptionshouldoccurwhile
thedeviceisON,thelightloadwillreturntoits
previousstatewhenpowerisrestored.
NOTE: TheSceneCapablePlug-InLamp
DimmingModulecancontroltheLoadbefore
beingincludedintheZ-Wave
®
network.After
poweringupmodule,wait10seconds,thenpress
theProgrammingON/OFFbuttontoturntheLoad
ONorOFF.
IftheSceneCapablePlug-InLampDimming
Moduleappearstobefunctioningimproperly,
proceedwiththefollowingsteps:
1.Conrmthatthedeviceisbeingsuppliedfrom
a120V,60HzACsourceONLY.
2.ConrmthattheLoadbeingcontrolledisin
properworkingorder(localswitchisON)and
checkforburned-outbulbs.
3.Conrmthattheloadbeingcontrolleddoesnot
exceedthe300Wmodulelimit.
4.Conrmthattheunitisprogrammedproperly.
Repeat“INSTALLINGYOURDIMMING
MODULE”sectiontoverifythatithasbeen
includedintoZ-Wave
TM
network.
TROUBLESHOOTING
DI-000-VRP03-02A2008©LevitonMfg.Co.,Inc.
For additional information, contact Leviton’s
Techline at 1-800-824-3005 or visit Leviton’s
website at www.ViziaRFplus.com
ProtectedunderU.S.PatentNumber6,388,399
andpatentspendingandlicensedunder
U.S.PatentsNumbers5,905,442,and5,982,103
NOTE:Itisveryimportanttoaccurately
Excludedevicesfromthenetworkwhen
movingorremovingadevicefromaZ-Wave
®
network.Thisensuresthatallinformationhas
beenremovedfromyourPrimaryProgrammer/
Remote’sinformationtableandisnotcounted
ontobeapartofthemeshnetwork.
A)IfusingaLevitonZ-Wave
®
Programmer/
Remote,Cat.No.VRCPG,presstheMenu
buttonandscrolldowntoSystemSetup.
PressthecenterbuttontoselectSystem
SetupMenu.ChooseAdvancedSettings.
PressthecenterbuttontoselectNetwork.
B)Whilestandingclosetothemodule,press
thecenterbuttonto<Exclude>devicefrom
thenetwork.
NOTE:Onlyonedevicemaybeexcludedat
atime.
C) WhiletheProgrammer/Remoteisinthe
ExclusionmodeandtheLEDisONonthe
SceneCapablePlug-InLampDimming
Module,presstheON/OFFbuttononthe
module.TheProgrammer/Remotewillverify
ExclusionandtheLEDwillturnOFFon
theSceneCapablePlug-InLampDimming
Module.
 IftheSceneCapablePlug-InLampDimming
ModuleisashingAmberwhileinthe
Exclusionmode,theProgrammer/Remoteis
stilltryingtocommunicatewiththemodule.
Waituntilthedevicestopsashing,then
presstheON/OFFbutton.
Excluding Plug-In Lamp
Dimming Module from
Network:
Step 4
Thisequipmenthasbeentestedandfound
tocomplywiththelimitsforaClassBDigital
Device,pursuanttoPart15oftheFCC
Rules.Theselimitsaredesignedtoprovide
reasonableprotectionagainstharmful
interferenceinaresidentialinstallation.
Thisequipmentgenerates,uses,andcan
radiateradiofrequencyenergyand,ifnot
installedandusedinaccordancewiththe
instructions,maycauseharmfulinterference
toradiocommunications.However,thereis
noguaranteethatinterferencewillnotoccur
inaparticularinstallation.Ifthisequipment
doescauseharmfulinterferencetoradioor
televisionreception,whichcanbedetermined
byturningtheequipmentOFFandON,
theuserisencouragedtotrytocorrectthe
interferencebyoneormoreofthefollowing
measures:
• ReorientorrelocatethereceivingAntenna.
• Increasetheseparationbetweenthe
equipmentandthereceiver.
• Connecttheequipmentintoanoutleton
acircuitdifferentfromthattowhichthe
receiverisconnected.
• Consultthedealeroranexperiencedradio/
tvtechnicianforhelp.
FCC COMPLIANCE STATEMENT
Factory Default:
Ifyourmoduleisnotresponding,oryouare
unabletocontrolitafteryouhavetriedtoInclude/
Excludeitmultipletimes,itmaybenecessaryto
resetthemoduletoitsoriginalfactorysettings.To
accomplishthis,proceedasfollows:
• Unplugthemoduleandwait5seconds.Plug
themodulebackinandwithin20seconds
pressandholdtheprogrammingbuttonuntil
theLEDturnsAmberandthenturnsRed.
Themoduleisnowreset.Oncethemoduleis
reset,itwillbenecessarytoRe-Includeittoa
networkbeforeitcanbeused.
CAUTION:SETTINGADEVICETOA
FACTORYDEFAULTDOESNOTEXCLUDE
THATDEVICEFROMANETWORK.THE
EXCLUSIONPROCEDUREMUSTSTILLBE
FOLLOWEDTOREMOVETHEDEVICEFROM
THEPRIMARYREMOTE’SINFORMATION
TABLE.FAILURETODOSOMAYRESULTIN
SYSTEMTHATISSLOWTORESPOND,OR
MAYFAILTORESPONDTOSOMEDEVICES.
Wall Receptacle
Lamp Plug
Scene Capable Plug-In
Lamp Dimming Module
NOTE: Programmer/Controller must be in close
proximity to Scene Capable Plug-In Lamp
Dimming Module when including into network
VRCPG Programmer/
Controller
MANUAL OPERATION:
ON: PressthebuttonontheScenePlug-InLamp
DimmingModuletoturnthelightsfromOFFto
ON.
NOTE:ThelightswillturnONfullBRIGHT
regardlessofthelastlevelset.
OFF:PresstheON/OFFbuttontoturnthelights
fromONtoOFF.
BRIGHTEN:PressandholdtheON/OFFbutton
toBRIGHTENthelightstothedesiredlevel.
DIM:PressandholdtheON/OFFbuttontoDIM
thelightstothedesiredlevel.
Including Scene
Capable Plug-In
Lamp Dimming
Module into
Z-Wave
®
Network:
Step 3 cont’d Step 4 cont’d
Press ON/OFF Button
  • Page 1 1
  • Page 2 2

Z-Wave VRP03-1LW Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI