LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
LevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenetofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforveyearsfromthe
purchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuchveyearperiodtheproductisreturnedprepaid,withproofofpurchasedate,andadescriptionoftheproblemtoLeviton
Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591.Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthisproductorreinstallation.
Thiswarranty isvoidif thisproduct isinstalledimproperly orin animproperenvironment, overloaded,misused, opened,abused, oralteredin anymanner,or isnot usedundernormal operatingconditions ornotinaccordancewith any
labelsorinstructions.There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuch
implied warranty, including merchantability and tnessforaparticular purpose, is limited to ve years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or
loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.
OPERATION
NOTE: Forcompletedetailsonoperatingthe
PrimaryProgrammer/Remote,refertothe
individualdevice’sinstructionguide.
ON:ThiscommandwillBRIGHTENthelightsto
thelastlevelset.
OFF:ThiscommandwillDIMthelightstoOFF.
BRIGHTEN:ThiscommandwillBRIGHTENthe
lightstothedesiredlevel.
DIM:ThiscommandwillDIMthelightstothe
desiredlevel.
MANUAL ON:IfSceneCapablePlug-InLamp
DimmingModuleisOFF,turntheswitchlocated
onthecontrolledlampOFFforafewseconds,
thenONagain.Themodulewillturnthelamp
ONtofullBRIGHT.Thisprocedurecanbe
usedtoturnONthelampwithoutaccessingthe
transmitter.
NOTE:Ifapowerinterruptionshouldoccurwhile
thedeviceisON,thelightloadwillreturntoits
previousstatewhenpowerisrestored.
NOTE: TheSceneCapablePlug-InLamp
DimmingModulecancontroltheLoadbefore
beingincludedintheZ-Wave
®
network.After
poweringupmodule,wait10seconds,thenpress
theProgrammingON/OFFbuttontoturntheLoad
ONorOFF.
IftheSceneCapablePlug-InLampDimming
Moduleappearstobefunctioningimproperly,
proceedwiththefollowingsteps:
1.Conrmthatthedeviceisbeingsuppliedfrom
a120V,60HzACsourceONLY.
2.ConrmthattheLoadbeingcontrolledisin
properworkingorder(localswitchisON)and
checkforburned-outbulbs.
3.Conrmthattheloadbeingcontrolleddoesnot
exceedthe300Wmodulelimit.
4.Conrmthattheunitisprogrammedproperly.
Repeat“INSTALLINGYOURDIMMING
MODULE”sectiontoverifythatithasbeen
includedintoZ-Wave
TM
network.
TROUBLESHOOTING
DI-000-VRP03-02A2008©LevitonMfg.Co.,Inc.
For additional information, contact Leviton’s
Techline at 1-800-824-3005 or visit Leviton’s
website at www.ViziaRFplus.com
ProtectedunderU.S.PatentNumber6,388,399
andpatentspendingandlicensedunder
U.S.PatentsNumbers5,905,442,and5,982,103
NOTE:Itisveryimportanttoaccurately
Excludedevicesfromthenetworkwhen
movingorremovingadevicefromaZ-Wave
®
network.Thisensuresthatallinformationhas
beenremovedfromyourPrimaryProgrammer/
Remote’sinformationtableandisnotcounted
ontobeapartofthemeshnetwork.
A)IfusingaLevitonZ-Wave
®
Programmer/
Remote,Cat.No.VRCPG,presstheMenu
buttonandscrolldowntoSystemSetup.
PressthecenterbuttontoselectSystem
SetupMenu.ChooseAdvancedSettings.
PressthecenterbuttontoselectNetwork.
B)Whilestandingclosetothemodule,press
thecenterbuttonto<Exclude>devicefrom
thenetwork.
NOTE:Onlyonedevicemaybeexcludedat
atime.
C) WhiletheProgrammer/Remoteisinthe
ExclusionmodeandtheLEDisONonthe
SceneCapablePlug-InLampDimming
Module,presstheON/OFFbuttononthe
module.TheProgrammer/Remotewillverify
ExclusionandtheLEDwillturnOFFon
theSceneCapablePlug-InLampDimming
Module.
IftheSceneCapablePlug-InLampDimming
ModuleisashingAmberwhileinthe
Exclusionmode,theProgrammer/Remoteis
stilltryingtocommunicatewiththemodule.
Waituntilthedevicestopsashing,then
presstheON/OFFbutton.
Excluding Plug-In Lamp
Dimming Module from
Network:
Step 4
Thisequipmenthasbeentestedandfound
tocomplywiththelimitsforaClassBDigital
Device,pursuanttoPart15oftheFCC
Rules.Theselimitsaredesignedtoprovide
reasonableprotectionagainstharmful
interferenceinaresidentialinstallation.
Thisequipmentgenerates,uses,andcan
radiateradiofrequencyenergyand,ifnot
installedandusedinaccordancewiththe
instructions,maycauseharmfulinterference
toradiocommunications.However,thereis
noguaranteethatinterferencewillnotoccur
inaparticularinstallation.Ifthisequipment
doescauseharmfulinterferencetoradioor
televisionreception,whichcanbedetermined
byturningtheequipmentOFFandON,
theuserisencouragedtotrytocorrectthe
interferencebyoneormoreofthefollowing
measures:
• ReorientorrelocatethereceivingAntenna.
• Increasetheseparationbetweenthe
equipmentandthereceiver.
• Connecttheequipmentintoanoutleton
acircuitdifferentfromthattowhichthe
receiverisconnected.
• Consultthedealeroranexperiencedradio/
tvtechnicianforhelp.
FCC COMPLIANCE STATEMENT
Factory Default:
Ifyourmoduleisnotresponding,oryouare
unabletocontrolitafteryouhavetriedtoInclude/
Excludeitmultipletimes,itmaybenecessaryto
resetthemoduletoitsoriginalfactorysettings.To
accomplishthis,proceedasfollows:
• Unplugthemoduleandwait5seconds.Plug
themodulebackinandwithin20seconds
pressandholdtheprogrammingbuttonuntil
theLEDturnsAmberandthenturnsRed.
Themoduleisnowreset.Oncethemoduleis
reset,itwillbenecessarytoRe-Includeittoa
networkbeforeitcanbeused.
CAUTION:SETTINGADEVICETOA
FACTORYDEFAULTDOESNOTEXCLUDE
THATDEVICEFROMANETWORK.THE
EXCLUSIONPROCEDUREMUSTSTILLBE
FOLLOWEDTOREMOVETHEDEVICEFROM
THEPRIMARYREMOTE’SINFORMATION
TABLE.FAILURETODOSOMAYRESULTIN
SYSTEMTHATISSLOWTORESPOND,OR
MAYFAILTORESPONDTOSOMEDEVICES.
Wall Receptacle
Lamp Plug
Scene Capable Plug-In
Lamp Dimming Module
NOTE: Programmer/Controller must be in close
proximity to Scene Capable Plug-In Lamp
Dimming Module when including into network
VRCPG Programmer/
Controller
MANUAL OPERATION:
ON: PressthebuttonontheScenePlug-InLamp
DimmingModuletoturnthelightsfromOFFto
ON.
NOTE:ThelightswillturnONfullBRIGHT
regardlessofthelastlevelset.
OFF:PresstheON/OFFbuttontoturnthelights
fromONtoOFF.
BRIGHTEN:PressandholdtheON/OFFbutton
toBRIGHTENthelightstothedesiredlevel.
DIM:PressandholdtheON/OFFbuttontoDIM
thelightstothedesiredlevel.
Including Scene
Capable Plug-In
Lamp Dimming
Module into
Z-Wave
®
Network:
Step 3 cont’d Step 4 cont’d
Press ON/OFF Button