  • Hello! I am an AI chatbot trained to assist you with the Airflow CE100D Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Ducted Fan Kit
CE100D
CE150DTP
Installation Instructions / Warranty Card
by
CE100D and CE150DTP Ducted Fan Kit Installation Instructions / Warranty
© Clipsal Australia Pty Ltd
Installation Instructions
Important:
For optimum effi ciency, position the fan unit as close as possible to the outlet.
1. Select positions for inlet and outlet grilles. These should be clear of all
obstructions and no more than three metres apart. Additionally, the outlet should
be positioned away from windows and doors.
2. Using template on opposite page, cut an opening for both inlet and outlet.
3. Drill 3.6mm holes through required corner fi xing points of inlet and outlet grilles.
4. Place three duct clips 120° apart on collars of both inlet and outlet grilles as well
as on each end of the fan body. (See fi gures 1, 2 and 3.)
5. Attach duct securely over outlet collar, push back into the roof space and secure
outlet with appropriate fi xings for mounting surface. If using screws supplied,
ensure white screw cap arrangements are used to cover screw holes.
6. Select a site for the fan unit as close as possible to the outlet on a stable platform
such as a beam or post. (A saddle may be needed).
7. Make the electrical connections to the fan unit and attach the shortest possible
length of duct from the outlet collar to the fan, making sure that air fl ow is in the
correct direction. Air fl ow direction is from the motor towards the fan blades. (You
may choose not to have any ducting at all between the fan and outlet by inserting
the fan directly into the outlet collar and securing it with duct tape).
8. Keeping as straight a line as possible between the inlet and outlet points, fully
extend duct to minimise restriction of air fl ow and cut the duct to fi t to the fan unit.
Attach duct securely to fan unit and attach the other end of the remaining duct to
the collar of the inlet grille, making sure to secure the duct by passing it over the
duct clips.
9. Push inlet grille into the opening and screw fi x it in the upward position with
screws and anka plugs supplied, and ensure the supplied white screw cap
arrangements are used to cover screw heads.
It is illegal for persons other than licensed electricians, or persons authorised
by legislation, to work on the fi xed wiring of any electrical device.
Fig. 1 - Outlet Fig. 2 - Inlet Fig. 3 - Fan Unit
Cable entry
to motor
Air fl ow
direction
© Clipsal Australia Pty Ltd
CE100D and CE150DTP Ducted Fan Kit Installation Instructions / Warranty
170mm outer
diameter for
inlet and outlet
for CE150DTP
120mm outer
diameter for
inlet and outlet
for CE100D
Centre hole
Template
Use this template to mark the mounting hole for the fan. Use a
nail or similar object to achor the template at the centre hole,
then insert a pencil through the template at the point indicated
adjacent to the correct fan size and scribe the circle.
F1680/03
CLIPCOM 17725 November 2008
Clipsal Australia Pty Ltd reserves the right to change specifications,
modify designs and dis con tin ue items without incurring obligation
and whilst every effort is made to ensure that descriptions,
specifications and other in for ma tion in this catalogue are correct, no
warranty is given in respect thereof and the company shall not be
liable for any error therein.
© Clipsal Australia Pty Ltd. The identifi ed trademarks and copyrights
are the property of Clipsal Australia Pty Ltd unless otherwise noted.
Product of Clipsal Australia Pty Ltd
A member of Schneider Electric
Contact us: clipsal.com/feedback
National Customer Care Enquiries:
Tel 1300 2025 25
Fax 1300 2025 56
clipsal.com
Warranty
The benefi ts conferred by this warranty are in addition to all other rights and remedies in
respect of the product which the consumer has under the Trade Practices Act and similar
State and Territory laws.
The original purchaser of this Airfl ow Ducted Fan Kit is provided with the following warranty,
subject to the following conditions. Clipsal Australia Pty Ltd warrant this product for a period
of 12 months from the date of purchase for all parts defective in workmanship or materials.
All defective parts will be replaced free of charge. The following exclusions do not preclude
the purchaser from those statutory rights consumers have under the Trade Practices Act or
similar State and Territory laws.
Warranty Conditions
1. This warranty is only valid for appliances installed according to the manufacturer’s
instructions.
2. This appliance must not be modifi ed or changed in any way.
3. All wiring must be carried out by a licensed electrician or similarly qualifi ed person and
must be connected to the voltage requirements as specifi ed on the ratings label.
4. The manufacturer does not accept liability for any direct or consequential damage,
loss or other expense arising from misuse or incorrect installation and operation of
the appliance.
5. Warranty will only be given on appliances where proof of purchase date is provided, e.g.
original invoice or copy.
6. As a record of your purchase, please fi ll out the following details and fi le this information
with your purchase invoice.
Airfl ow Model Number:
Serial Number:
Purchased From:
Date of Purchase:
For Service
Please contact the installer if service is required for this product. If the installer is not
known, contact Clipsal National Customer Care on the following numbers:
Tel 1300 2025 25
Fax 1300 2025 56
/