Clipsal Ceiling Sweep Fan Operating instructions

Type
Operating instructions

Clipsal Ceiling Sweep Fan is a registered design and registered patent that ensures years of trouble-free operation. It has a three-speed fan controller that can operate a single fan and up to eight fans using a Clipsal C-Thru Electronic Fan Controller which is purchased separately. The fan has a minimum of 2.1m clearance from the floor and is suitable for pitched ceilings with a maximum angle of 18.5°. The blades are also a matched set to ensure proper balance and are easy to maintain.

Clipsal Ceiling Sweep Fan is a registered design and registered patent that ensures years of trouble-free operation. It has a three-speed fan controller that can operate a single fan and up to eight fans using a Clipsal C-Thru Electronic Fan Controller which is purchased separately. The fan has a minimum of 2.1m clearance from the floor and is suitable for pitched ceilings with a maximum angle of 18.5°. The blades are also a matched set to ensure proper balance and are easy to maintain.

Included with your Fan
23606_F2365 Airflow Ceiling Sweep Fan A4 PRESS.indd 1 21/09/2011 11:30:12 AM
Installation Instructions
REGISTERED DESIGN • REGISTERED PATENT
Where multiple fans are required to be operated from a single
controller, a Clipsal C-ThruTM Electronic Fan Controller
(purchased separately) must be used.
NOTICE
HAZARD OF INCORRECT ASSEMBLY
To ensure proper balance, do not mix up blades with those
from another fan as they are a matched set.
Transport and transit handling may loosen factory fitted
cables. Please check and secure terminal screws before
installation
Failure to follow these instructions can result in
equipment damage
Included with your Fan
A. Motor Assembly
B. Four Blades
C. Three-Speed Fan Controller
Controlling a Single Fan
This fan has been supplied with a Clipsal Three-Speed
Controller that is designed to operate a single fan.
Multiple Fans on a Single Controller
Protecting the Fan
D. Screw Pack
E. Mounting Bracket
F. Instruction Sheet
Installation Instructions
REGISTERED DESIGN • REGISTERED PATENT
You can control up to eight Airflow Fans using a Clipsal
C-ThruTM Electronic Fan Controller (purchased separately).
NOTE: The three-speed fan controller supplied with each fan is
not suitable for controlling multiple fans.
IMPORTANT NOTES
1. To ensure proper balance, the blades are a matched set. Do
not mix up the blades with those from another fan.
2. Transport and transit handling may loosen factory fitted
cables. Please check and secure terminal screws before
installation.
All electrical work must be carried
out by a qualified electrician.
Included with your Fan
A. Motor Assembly
B. Four Blades
C. Three-Speed Fan Controller
Blades:
Minimum 2.1m
above floor.
Minimum
300mm from
other obstacles.
18.5°
Controlling a Single Fan
This fan has been supplied with a quality Clipsal Three-Speed
Controller that is designed to operate a single fan.
OFF 13 2
Multiple Fans on a Single Controller
Clearances and Angled Ceilings
Hangsure Mounting
Suitable for pitched ceilings
with a maximum angle of 18.5°.
Protecting the Fan
Do not place the motor directly onto a flat surface.
The plastic nipple underneath the motor cannot support the
weight of the motor and may be easily damaged. When working
on the fan, place the motor on the foam packaging with the
nipple located in one of the recesses. This protects the nipple
and the finish.
D. Screw Pack
E. Mounting Bracket
F. Instruction Sheet
Plastic Nipple
Foam
Packaging
Hangsure Bracket or J-Hook Bracket
Ceiling Sweep Fan
4HS1200, 4HS1400, 4JH1200, 4JH1400
Thank you for purchasing this Airflow Ceiling Sweep Fan. You can be assured of
trouble-free operation for years by installing your ceiling fan carefully and according to these instructions.
Please read all the instructions before commencing, then complete each step in order.
23606_F2365 Airflow Ceiling Sweep Fan A4 PRESS.indd 1 21/09/2011 11:30:12 AM
Foam
Packaging
Ceiling Sweep Fan
4HS1200, 4HS1400, 4JH1200, 4JH1400 Series
Thank you for purchasing this Airflow Ceiling Sweep Fan. You can be assured of
trouble-free operation by installing your ceiling fan carefully and according to these instructions.
Please read all the instructions before commencing, then complete each step in order.
Plastic Nipple
Hangsure Bracket or J-Hook Bracket
Ceiling Sweep Fan
23606_F2365 Airflow Ceiling Sweep Fan A4 PRESS.indd 1 21/09/2011 11:30:12 AM
NOTICE
HAZARD OF PRODUCT DAMAGE
Do not place the motor directly onto a flat surface.
The plastic nipple underneath the motor cannot support
the weight of the motor and may be easily damaged. When
working on the fan, place the motor on the foam packaging
with the nipple located in one of the recesses. This protects
the nipple and the finish.
Failure to follow these instructions can result in
equipment damage
DANGER
HAZARD OF ELECTRIC SHOCK OR ARC FLASH
This equipment must only be installed and serviced by
appropriate qualified and/or licenced electrical personnel.
Isolate the electrical supply before doing any work on
this equipment
Ensure that the product had been correctly installed and tested
operation before reconnecting the electrical supply.
Failure to follow these instructions will result in death
or serious injury.
NOTICE
HAZARD OF INCORRECT USAGE
The three-speed fan controller supplied with each fan is not
suitable for controlling multiple fans.
Failure to follow these instructions can result in
equipment damage
OFF 13 2
Installation Instructions
REGISTERED DESIGN • REGISTERED PATENT
You can control up to eight Airflow Fans using a Clipsal
C-ThruTM Electronic Fan Controller (purchased separately).
NOTE: The three-speed fan controller supplied with each fan is
not suitable for controlling multiple fans.
IMPORTANT NOTES
1. To ensure proper balance, the blades are a matched set. Do
not mix up the blades with those from another fan.
2. Transport and transit handling may loosen factory fitted
cables. Please check and secure terminal screws before
installation.
All electrical work must be carried
out by a qualified electrician.
Included with your Fan
A. Motor Assembly
B. Four Blades
C. Three-Speed Fan Controller
Blades:
Minimum 2.1m
above floor.
Minimum
300mm from
other obstacles.
18.5°
Controlling a Single Fan
This fan has been supplied with a quality Clipsal Three-Speed
Controller that is designed to operate a single fan.
OFF 13 2
Multiple Fans on a Single Controller
Clearances and Angled Ceilings
Hangsure Mounting
Suitable for pitched ceilings
with a maximum angle of 18.5°.
Protecting the Fan
Do not place the motor directly onto a flat surface.
The plastic nipple underneath the motor cannot support the
weight of the motor and may be easily damaged. When working
on the fan, place the motor on the foam packaging with the
nipple located in one of the recesses. This protects the nipple
and the finish.
D. Screw Pack
E. Mounting Bracket
F. Instruction Sheet
Plastic Nipple Foam
Packaging
Hangsure Bracket or J-Hook Bracket
Ceiling Sweep Fan
4HS1200, 4HS1400, 4JH1200, 4JH1400
Thank you for purchasing this Airflow Ceiling Sweep Fan. You can be assured of
trouble-free operation for years by installing your ceiling fan carefully and according to these instructions.
Please read all the instructions before commencing, then complete each step in order.
23606_F2365 Airflow Ceiling Sweep Fan A4 PRESS.indd 1 21/09/2011 11:30:12 AM
Ceiling Sweep Fan
23606_F2365 Airflow Ceiling Sweep Fan A4 PRESS.indd 1 21/09/2011 11:30:12 AM
4HS1200, 4HS1400, 4JH1200, 4JH1400 Ceiling Sweep Fan Installation Instructions
Slide blade over screws
Foam
Packaging
Support the motor Remove plastic spacer
A B
C
Tighten screws
D
Mounting the Fan Support Bracket
Slide blade over screws
Foam
Packaging
Slide blade over screws
Foam
Packaging
Support the motor Remove plastic spacer
A B
Tighten screws
D
Mounting the Fan Support Bracket
Support the motor Motor Screw Holes
A B
C
Slide blade over screws
Foam
Packaging
Support the motor Remove plastic spacer
A B
C
Tighten screws
D
Mounting the Fan Support Bracket
Tighten screws
D
J-Hook Bracket
Fit the rubber wheel assembly over mounting
5-10mm gap
(between ceiling
and cowling)
Screw
1.0 Mounting the Fan Support Bracket
Ceiling Sweep Fan
23606_F2365 Airflow Ceiling Sweep Fan A4 PRESS.indd 1 21/09/2011 11:30:12 AM
Secure fixing to support 15kg Secure fixing to support 15kg
Hangsure Mounting J-Hook Mounting
2.0 Fitting the Blades
Place the blade over the motor and align screws.
Securely tighten both screws.
3.0 Connecting the Light Fitting
If you are attaching a light fitting to the fan, do so prior to hanging
the fan.
NOTE:
Clipper Light or Oyster Light may be installed in fans that are
constructed for this purpose.
1. Unscrew the plastic nipple from the bottom of the
motor housing.
2. Pull out the light wires from the motor housing for connection
with the lamp holder.
3. Insert the light wires through the adaptor, then screw the
adaptor into the motor shaft.
4. Connect the light wires to the lamp holder then screw the
lamp holder and the adaptor together firmly.
Light Wires Adaptor
Lamp Holder
Light Wires
Plastic Nipple
Ceiling
Cowling
4.0 Hanging the Fan
Hangsure Bracket
Position the ball-joint in the bracket so that the guide pin on the
bracket engages in the slot in the ball-joint.
© 2011 Schneider Electric. All Rights Reserved.
2 of 4
WARNING
LOCATION HAZARD
Select a suitable location to mount the fan support bracket.
The mounting bracket must be fixed to a solid structural
member, such as a ceiling joist or a securely fixed noggin,
and be capable of supporting 15 kg.
Additionally, it is recommended to provide the blade with a
minimum clearance from the floor of 2.1m, and from other
obstructions of at least 300mm.
Failure to follow these instructions can result in injury or
equipment damage
Secure fixing to support 15kg
Blades:
Minimum 2.1m
above floor.
Minimum
300mm from
other obstacles.
18.5°
Clearances and Angled Ceilings
Hangsure Mounting
Suitable for pitched ceilings
with a maximum angle of 18.5°.
NOTICE
HAZARD OF CEILING DAMAGE
For j-hook brackets, leave a 5-10mm gap between the ceiling
and cowling. It’s normal for the cowling to move slightly when
the fan is running. This gap prevents damaging the painted
ceiling and prevents ticking or clicking noises.
Failure to follow these instructions can result in
equipment damage
Ceiling Sweep Fan
23606_F2365 Airflow Ceiling Sweep Fan A4 PRESS.indd 1 21/09/2011 11:30:12 AM
Guide Pin Slot
4HS1200, 4HS1400, 4JH1200, 4JH1400 Ceiling Sweep Fan Installation Instructions
3 of 4
© 2011 Schneider Electric. All Rights Reserved.
6.0 Connecting the Speed Controller
All Airflow Ceiling Sweep Fans come complete with a
three-speed flush fitting capacitor controller.
This controller fits to standard 84mm fixing centres, the same as
a normal switch or power point.
Although supplied standard in the vertical format, the mechanism
can be rotated 90° to provide a horizontal format if required.
To ensure that the “off position of the switch is at the top when
installed, the mechanism must be installed into the plate with the
three screw heads pointing upwards. The mechanism must be
fully "clipped" into the plate from the rear. Three is the highest
speed, one is the lowest.
Remove switch surround.
Terminate cables as illustrated in the below diagram.
Active to common and switched active to terminal one.
Fix controller to wallbox or bracket using screws provided.
Screws may need to be shortened for some applications.
Replace switch surround.
Connecting the speed controller with a light switch requires
additional components (not supplied with this fan) including:
- Clipsal 30M Switch Mechanism
- Two gang grid plate and cover.
5.0 Connecting the Fan
All Airflow Ceiling Sweep Fans are pre-wired to allow for a light to
be fitted onto the fan.
If you are not fitting a light to the fan, please disregard the light
wires. The wires are connected to the incoming wiring as illus-
trated in the below diagram.
Means for all pole disconnection must be incorporated in the
fixed wiring in accordance with the wiring rules.
Fan Only
8.0 Operating Instructions
Turn the knob to speed three (top position). This will start the
blades spinning.
Once the blades are spinning you can select a lower speed
if desired.
The speed setting is always located at the top position of the
knob as illustrated below.
Fan with Light
COM
ACTIVE
SWITCHED
ACTIVE (Fan)
2
13
Capacitor
ROTARY SWITCH
MECHANISM
COM
L
21
SWITCHED
ACTIVE (Light)
CLIPSAL 30M
SWITCH
MECHANISM
7.0 Connecting the Speed Controller
with a Light Switch
ACTIVE
SWITCHED ACTIVE
(TO FAN MOTOR)
ROTARY SWITCH
MECHANISM
COM
2
13
Capacitor
RED
ORANGE
PURPLE
Top Position
SWITCHED
ACTIVE (Fan)
NEUTRAL
SWITCHED ACTIVE
(Optional Light)
EARTH
BROWN
BLUE
RED
GREEN
BROWN
BLUE
RED
GREEN
4HS1200, 4HS1400, 4JH1200, 4JH1400 Ceiling Sweep Fan Installation Instructions
Summer/Winter Settings
The forward/reversible switch is located on the bottom cowl.
Check switch and make sure it is in correct setting, depending on
cold weather or hot weather.
Cold weather: Push switch down for the blades to circulate the
warm air trapped near the ceiling.
Hot weather: Push switch up for the blades to create a breeze
and circulate the air.
NOTE:
The forward/reversible switch must be fully engaged for the fan
to operate.
Troubleshooting Guide
Fan will not switch on.
• Switch off the fan. Then check the following:
• forward/reverse switch on fan motor not fully engaged in
desired setting
• connections not as per installation diagram
• fuse blown, circuit breaker tripped or there is a power failure.
Fan will not operate at varying speed control settings.
• Controller connections not as per page 3.
Ticking, rattling, mechanical noises.
• Ensure all screws and bolts are tight.
• Ensure the mounting assembly is secure.
• Ensure the lower canopy is clear of the motor.
• With hook mount models, ensure the top canopy is clear of the
ceiling by 5 to 10mm to allow for slight movement of the fan.
• Ensure the wires are not tapping against the canopy.
For further technical support contact the Clipsal National
Customer Service Centre on 1300 2025 25.
Warranty
The benefits conferred by this warranty are in addition to all implied
warranties, other rights and remedies in respect of the product which
the consumer has under the Trade Practices Act and similar State and
Territory Laws.
The original purchaser of this Airflow Ceiling Sweep Fan, is provided with
the following warranty, subject to the following conditions:
Schneider (Australia) Pty Ltd warrant this product for a period of three
years from the date of purchase for all parts defective in workmanship or
materials. All products used in commercial applications are limited to a 90
day warranty.
All defective parts will be replaced free of charge. The following exclusions
do not preclude the purchaser from those statutory rights consumers have
under the Trade Practices Act or similar State and Territory Laws.
WARRANTY CONDITIONS:
1. This warranty is only valid for appliances installed according to the
manufacturers instructions.
2. This appliance must not be modified or changed in any way
and all electrical connections must be carried out by a
qualified electrician only.
3. Connection must be to the voltage requirements as specified in the
ratings label located on the product.
4. The manufacturer does not accept liability for any direct or
consequential damage, loss or other expense arising from misuse
or incorrect installation and operation of the appliance.
5. Warranty will only be given where proof of purchase is provided,
e.g. original invoice.
6. For warranty to be valid only Airflow accessories, such as down rods
and light kits, shall be installed with the Airflow Ceiling Sweep Fan.
IMPORTANT
Record this warranty information at the time of purchase but do not send
this information unless you are making a claim or are asked to do so.
To obtain service under warranty you must retain your original purchase
receipt, service will otherwise be charged at current rates.
Model No.:
Purchase from:
Name:
Address:
Postcode:
Date of purchase:
CLIPCOM 23606 June 2015
F2365/01
Cleaning Instructions
To clean the fan, wipe over with a damp, soapy cloth.
Do not use scourers or abrasive cleaners.
SUMMER
WINTER
Schneider Electric (Australia) Pty Ltd
Contact us: clipsal.com/feedback
National Customer Care Enquiries:
Tel 1300 2025 25 Fax 1300 2025 56
Schneider Electric (Australia) Pty Ltd reserves the right to change specifications, modify designs
and discontinue items without incurring obligation and whilst every effort is made to ensure that
descriptions, specifications and other information in this catalogue are correct, no warranty is given
in respect thereof and the company shall not be liable for any error therein.
© 2011 Schneider Electric. All Rights Reserved.
Trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.
4HS1200, 4HS1400, 4JH1200, 4JH1400 Ceiling Sweep Fan Installation Instructions
Summer/Winter Settings
The forward/reversible switch is located on the bottom cowl.
Check switch and make sure it is in correct setting, depending on
cold weather or hot weather.
Cold weather: Push switch down for the blades to circulate the
warm air trapped near the ceiling.
Hot weather: Push switch up for the blades to create a breeze
and circulate the air.
NOTE:
The forward/reversible switch must be fully engaged for the fan
to operate.
Troubleshooting Guide
Fan will not switch on.
•Switchoffthefan.Thencheckthefollowing:
•forward/reverseswitchonfanmotornotfullyengagedin
desired setting
•connectionsnotasperinstallationdiagram
•fuseblown,circuitbreakertrippedorthereisapowerfailure.
Fan will not operate at varying speed control settings.
•Controllerconnectionsnotasperpage3.
Ticking, rattling, mechanical noises.
•Ensureallscrewsandboltsaretight.
•Ensurethemountingassemblyissecure.
•Ensurethelowercanopyisclearofthemotor.
•Withhookmountmodels,ensurethetopcanopyisclearofthe
ceiling by 5 to 10mm to allow for slight movement of the fan.
•Ensurethewiresarenottappingagainstthecanopy.
WARNING:
Do not attempt to stop the blades by hand, even at low speed.
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
Ensure all supplies are disconnected before cleaning, maintenance
and attachment of lamp kit.
For further technical support contact the Clipsal National
Customer Service Centre on 1300 2025 25.
Warranty
The benefits conferred by this warranty are in addition to all implied
warranties, other rights and remedies in respect of the product which
the consumer has under the Trade Practices Act and similar State and
Territory Laws.
The original purchaser of this Airflow Ceiling Sweep Fan, is provided with
the following warranty, subject to the following conditions:
Schneider (Australia) Pty Ltd warrant this product for a period of three
years from the date of purchase for all parts defective in workmanship or
materials. All products used in commercial applications are limited to a 90
day warranty.
All defective parts will be replaced free of charge. The following exclusions
do not preclude the purchaser from those statutory rights consumers have
under the Trade Practices Act or similar State and Territory Laws.
WARRANTY CONDITIONS:
1. This warranty is only valid for appliances installed according to the
manufacturers instructions.
2. This appliance must not be modified or changed in any way
and all electrical connections must be carried out by a
qualified electrician only.
3. Connection must be to the voltage requirements as specified in the
ratings label located on the product.
4. The manufacturer does not accept liability for any direct or
consequential damage, loss or other expense arising from misuse
or incorrect installation and operation of the appliance.
5. Warranty will only be given where proof of purchase is provided,
e.g. original invoice.
6. For warranty to be valid only Airflow accessories, such as down rods
and light kits, shall be installed with the Airflow Ceiling Sweep Fan.
IMPORTANT
Record this warranty information at the time of purchase but do not send
this information unless you are making a claim or are asked to do so.
To obtain service under warranty you must retain your original purchase
receipt, service will otherwise be charged at current rates.
Model No.:
Purchase from:
Name:
Address:
Postcode:
Date of purchase:
ALSO AVAILABLE FROM
C-ThruTM Electronic Fan Controllers
• Rapid Fan Start Feature
Variable Speed Adjustment
• Control up to Eight Airow Fans
• Multiple Plate Styles Available.
ALL ELECTRICAL WORK MUST BE CARRIED
OUT BY A QUALIFIED ELECTRICIAN.
CLIPCOM 23606 September 2011
F2365/01
Cleaning Instructions
To clean the fan, wipe over with a damp, soapy cloth.
Do not use scourers or abrasive cleaners.
SUMMER
WINTER
Schneider Electric (Australia) Pty Ltd
Contact us: clipsal.com/feedback
National Customer Care Enquiries:
Tel 1300 2025 25 Fax 1300 2025 56
Schneider Electric (Australia) Pty Ltd reserves the right to change specifications, modify designs
and discontinue items without incurring obligation and whilst every effort is made to ensure that
descriptions, specifications and other information in this catalogue are correct, no warranty is given
in respect thereof and the company shall not be liable for any error therein.
© 2011 Schneider Electric. All Rights Reserved.
Trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.
23606_F2365 Airflow Ceiling Sweep Fan A4 PRESS.indd 4 21/09/2011 11:30:13 AM
CAUTION
MOVING PARTS OR ELECTRICAL HAZARD
Do not attempt to stop the blades by hand, even at low speed.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised
to ensure that they do not play with the appliance.
Ensure all electrical supplies are disconnected before cleaning,
maintenance and attachment of lamp kit.
Failure to follow these instructions can result in injury or
equipment damage
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Clipsal Ceiling Sweep Fan Operating instructions

Type
Operating instructions

Clipsal Ceiling Sweep Fan is a registered design and registered patent that ensures years of trouble-free operation. It has a three-speed fan controller that can operate a single fan and up to eight fans using a Clipsal C-Thru Electronic Fan Controller which is purchased separately. The fan has a minimum of 2.1m clearance from the floor and is suitable for pitched ceilings with a maximum angle of 18.5°. The blades are also a matched set to ensure proper balance and are easy to maintain.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI