Axis T90A01 IR LED illuminator Installation guide

Category
Infrared bulbs
Type
Installation guide

This manual is also suitable for

AXIS T90A Installation Guide Page 3
ENGLISH
AXIS T90A Illuminator
This guide provides instructions for installing the AXIS T90A 2x/3x/4x. The contents of this guide are
as follows:
1. Package Contents. See below
2. Installation, on page 5
3. Setup, on page 6
4. PSU specifications, on page 7
5. Power Supply Features, on page 8
6. Technical drawings, on page 9
Package Contents
AXIS T90A Illuminator with bracket
Power Supply (PSU)
Installation guide (this document)
Page 4 AXIS T90A Installation Guide
Overview
Power supply (PSU)
AXIS T90A Illuminator
!
1.5m
Adaptive illumination
bolt
LED illuminator
Bracket
LED output cable x2
(2.5m)
Photocell (automatic
operation)
Mains input
LED input 2
LED input 1
Isolate mains
before removing
cover
Mount PSU
to flat surface
Install in a
well-ventilated
area
Do not
continually
stare at lamp
Specifications subject to change without notice.
AXIS T90A Installation Guide Page 5
ENGLISH
Installation
Follow these installation procedures:
1. Mount the illuminator.
2. Mount the PSU.
3. Extend or reduce the lead length as you wish.
4. Connect the LED output.
5. Adjust the PSU and telemetry if required. (Telemetry input is used when you require to remotely
control the illuminator.)
6. Connect the mains.
10cm - 10m
!
3
4
!
6
!
2
1
5
6
CAUTION: Red = +ve
Black = -ve
(polarity sensitive)
CAUTION:
Connect all leads
LED output x2
Mains in
Telemetry input
and tighten fixing
s
Page 6 AXIS T90A Installation Guide
Setup
Follow these instructions to set up the illuminator.
1. It is recommended that you set the illuminator up at night.
2. Adjust the illumination vertically so you light up the target area.
3. Adjust the illumination horizontally via Adaptive Illumination to match illumination to the
camera’s field of view.
4. Tighten all connections.
CAUTION: Do not fully loosen bolt
Camera
Camera
Camera
Light
Light
Light
Match illumination to camera’s field of view
Target
AXIS T90A Installation Guide Page 7
ENGLISH
PSU specifications
Infra-red series
White-light series
AXIS T90A 4x AXIS T90A 3x AXIS T90A 2x AXIS T90A 1x
Input AC 100-240
universal < 80W
AC 100-240
universal <40W
AC 100-240
universal < 20W
AC 100-240 universal
< 10W
Fuse 2.5A anti-surge 2.5A anti-surge 1A anti-surge 1A anti-surge
Output 4.4A @ 13.5V 2.4A @ 13.5V 1A @ 13.5V 0.5A @ 13.5V
Adjustable
Power
10% - 100% 10% - 100% 10% - 100% 10% - 100%
Weight 1.85 kg 1.65 kg 0.9 kg 0.8 kg
Dimensions
L x W x D
160 x 160 x 81 160 x 160 x 81 160 x 100 x 61 160 x 100 x 61
Drilling
Dimensions
4 x M4 holes @
145 x 123mm
4 x M4 holes @
145 x 123mm
4 x M4 holes @
145 x 63mm
4 x M4 holes @ 145 x
63mm
AXIS T90A 4x AXIS T90A 3x AXIS T90A 2x AXIS T90A 1x
Input AC 100-240
universal < 80W
AC 100-240
universal <40W
AC 100-240
universal < 20W
AC 100-240 universal
< 10W
Fuse 2.5A anti-surge 2.5A anti-surge 1A anti-surge 1A anti-surge
Output 4.4A @ 14V 2.8A @ 14V 1.4A @ 14V 0.7A @ 14V
Adjustable
Power
10% - 100% 10% - 100% 10% - 100% 10% - 100%
Weight 1.85 kg 1.65 kg 0.9 kg 0.8 kg
Dimensions
L x W x D
160 x 160 x 81 160 x 160 x 81 160 x 100 x 61 160 x 100 x 61
Drilling
Dimensions
4 x M4 holes @
145 x 123mm
4 x M4 holes @
145 x 123mm
4 x M4 holes @
145 x 63mm
4 x M4 holes @ 145 x
63mm
Page 8 AXIS T90A Installation Guide
Power Supply Features
The following are the power supply features:
Adjustable photocell
Adjustable power
Telemetry input
Photocell following contact (premium only)
12V DC output (premium only)
Power supply diagrams
Infra-Red and White-light
AXIS T90A 4x/3x models
Infra-Red and White-light
AXIS T90A 2x/1x models
Photocell following
contact - volt free,
non polarity sensitive
(Premium PSU only)
Telemetry Input -
- requires zero volt latched input
Photocell sensitivity
Mains Input
(100V to 240V AC)
12V DC power output
(Premium PSU only)
Photocell
Power adjustment
LED Output x2
(Polarity sensitive)
Power adjustment
Telemetry Input-
requires zero volt latched input
Photocell sensitivity
Mains Input
(100V to 240V AC)
LED Output x 2
(polarity sensitive)
AXIS T90A Installation Guide Page 9
ENGLISH
Technical drawings
For more information on optional brackets please see www.axis.com
72mm52mm
36mm
25mm
12.5mm
47mm
Standard brackets
Optional brackets
Wall mount
PTZ mount
Dome mount Pole mount
AXIS T90A 2/3/4x
AXIS T90A 1x
Installation Guide Ver.1.0
AXIS T90A Printed: August 2008
© Axis Communications AB, 2008
Part No. 32718
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43

Axis T90A01 IR LED illuminator Installation guide

Category
Infrared bulbs
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI