Z-Wave VRCZ1-1LZ Owner's manual

Type
Owner's manual

Z-Wave VRCZ1-1LZ is a 1-Zone Dimming Controller and Virtual Matching Dimmer Remote designed to provide remote control of your lighting. It operates on a 120VAC, 60Hz power supply and can be used with copper or copper clad wire. No traveler wires are needed as it communicates via radio frequency (RF) technology.

The device features ON/OFF and Brightness level LEDs for 2-way status reporting. It is compatible with other Z-Wave enabled devices and can be included in a Z-Wave network regardless of the manufacturer.

Z-Wave VRCZ1-1LZ is a 1-Zone Dimming Controller and Virtual Matching Dimmer Remote designed to provide remote control of your lighting. It operates on a 120VAC, 60Hz power supply and can be used with copper or copper clad wire. No traveler wires are needed as it communicates via radio frequency (RF) technology.

The device features ON/OFF and Brightness level LEDs for 2-way status reporting. It is compatible with other Z-Wave enabled devices and can be included in a Z-Wave network regardless of the manufacturer.

Including 1-Zone Controller into Z-Wave
®
Network:
NOTES:
• Ifusinganon-LevitonProgrammer/Remote,refertothe
Programmer/RemoteinstructionsheetforIncludingadevice.
• 1-zonecontrollersincludedintoaZ-Wave
®
networkmustbeupdated
afteryouhaveincludedallotherdevices.
• IfusingtheVRCPG'sInstallChecklistfeature,godirectlytoStepC.
A) IfusingaLevitonZ-Wave
®
Programmer/Remote,Cat.No.VRCPG,
presstheMenubuttonandscrolldowntoSystemSetup.Press
thecenterbuttontoselectSystemSetupMenu.ChooseAdvanced
Settings.PressthecenterbuttontoselectNetwork.Pressthecenter
buttonto<IncludeNode>.
B) IfusingVRCPGProgrammer/Remote,youwillbepromptedtoplace
1-zonecontrollerintoprogrammingmode.
C) ToaccessProgrammode,engagetheair-gap
switchbygentlypressingthetopofthepush
paduntilthebottomliftscompletelyoutofthe
frameandaclickisheard(refer to figure).
Wait5secondsandthenpressthepushpad
backintotheframeandholdpushpaduntil
theLEDturnsAmber.Releasethepushpad
andtheLEDshouldblinkAmber.Youarenow
inProgrammingmode.
NOTE:IftheLEDonthe1-zonecontroller
turnssolidRedwhileincluding,therehas
beenacommunicationerror.
D) Whilestandingclosetothe1-zonecontroller
(approximately2-5ft.),pressthecenter
buttonontheProgrammer/Remoteto
<Include>deviceinthenetwork.NOTE:Only
onedevicemaybeincludedatanytime.
E) TheVRCPGProgrammer/RemotewillassignaHomeID,NodeID
andNameforthisdevice.
NOTE:ThisinformationwillbestoredintheProgrammer/Remoteto
beusedforfuturereference.
NOTE:Youmaynameoreditthenodeofthisdeviceatthistime.
F) The 1-zone controller is now installed in the network.
WARNINGS AND CAUTIONS:
• ON/OFFLEDandBrightnesslevelLEDfor2-waystatusreporting.
• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.
• Ifyouareunsureaboutanypartoftheseinstructions,consultaqualiedelectrician.
• ViziaRF+
TM
VRCZ11-ZoneDimmingControllerdoesnotcontroltheload,butprovides3-wayor4-wayapplicationstooperatewithViziaRF+
TM
dimmer.
WARNINGS AND CAUTIONS:
• Recommendedminimumwallboxdepthis2-1/2".
•Notravelerwiresareneeded.Remotecontrolsviaradiofrequency(RF)technology.
• Disconnectpoweratcircuitbreakerorfusewhenservicing,installingorremovingxture.
• Usethisdeviceonlywithcopperorcoppercladwire.WithaluminumwireuseonlydevicesmarkedCO/ALRorCU/AL.
1-Zone Dimming Controller/
Virtual Matching Dimmer Remote
Cat.No.VRCZ1
120VAC,60Hz
INSTALLATION INSTRUCTIONS
DI-000-VRCZ1-02A
Changing the color of your 1-Zone Controller:
Yourdevicemayincludecoloroptions.Tochangecoloroftheface,
proceedasfollows:
Push in
side at tab
to release
INSTALLING YOUR 1-ZONE CONTROLLER
NOTE:UsecheckboxeswhenStepsarecompleted.
WIRING 1-ZONE CONTROLLER:
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• LineHotwallboxwiretoterminalscrewmarked"BK".
• LineNeutralwallboxwiretoterminalscrewmarked"WH".
• Proceed to Step 5.
Step 8
Wiring Application:
Hot (Bla c k )
Neutral (White)
BK WH
Green
Ground
Line
120 V A C , 60H z
1-Zone Controller
Step 4
Testing your 1-Zone Controller prior to mounting
in wall box:
• Positionallwirestoprovideroomin
outletwallboxfordevice.
• Ensurethattheword“TOP”isfacingup
ondevicestrap.
• Partiallyscrewinmountingscrewsin
wallboxmountingholes.
NOTE:Dresswires
withabendas
shownindiagram
inordertorelieve
stresswhen
mountingdevice.
• Restorepoweratcircuitbreakerorfuse.
• LEDshouldturnON.
If LED does not turn ON, refer to the
TROUBLESHOOTING section.
Step 5
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&/./&&
/./&&
/./&&
/./&&
/./&&
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN
OFF POWER atcircuitbreakerorfuseandtestthatpoweris
offbeforewiring!
Step 1
Step 3
Preparing and connecting wires:
This1-zonecontrollercanbewiredusingsidewireterminal
screwsorthroughbackwireopenings.Chooseappropriatewire
strippingspecicationsaccordingly.
• Makesurethattheendsofthewiresfromthewallboxare
straight (cut if necessary).
5/8"
(1.6 cm)
Strip Gage
(measure bare
wire here)
Cut
(if necessary)
Side Wire Connection
Sidewireterminalsaccept#14
AWGsolid wire copper only.
Back Wire (either hole may be used)
Backwireopeningsuse#14-12AWG
solid wire copper only.
2
3
1
2
1.Line(Hot)
2.Neutral
3.Ground
Identifying your wiring application (most common):
NOTE:Ifthewiringinyourwallboxdoesnotresemblethis
conguration,consultaqualiedelectrician.
Step 2
INTRODUCTION
Leviton’sViziaRF+
TM
componentsaredesignedtocommunicate
witheachotherviaRadioFrequency(RF)toprovideremotecontrol
ofyourlighting.UsingRFtechnologyallowsLevitontoprovidethe
greatestsignalintegritypossible.EachmoduleinLeviton’sViziaRF+
TM
componentlineisaZ-Wave
®
enableddevice.InaZ-Wave
®
network,
eachdeviceisdesignedtoactasarouter.Theserouterswillre-transmit
theRFsignalfromonedevicetoanotheruntiltheintendeddeviceis
reached.Thisensuresthatthesignalisreceivedbyitsintendeddevice
byroutingthesignalaroundobstaclesandradiodeadspots.The1-Zone
DimmingController/VirtualMatchingDimmerRemoteiscompatiblewith
anyZ-Wave
®
enablednetwork,regardlessofthemanufacturerandcan
alsobeusedwithotherdevicesdisplayingtheZ-Wave
®
logo.
• ThisisaZ-Wave
®
Controller
• 3-wayor4-waycontrolwithouttravelerwires
• Controlsdimmingofremoteload
• ON/OFFLEDandBrightnesslevelLED
• Twowaycommunication
• RFreliability
• Easeofinstallation–Nonewwiring
• CompatiblewithotherZ-Wave
®
enableddevices
FEATURES
Tools needed to install your 1-Zone Controller
Slotted/PhillipsScrewdriver ElectricalTape Pliers
Pencil Cutters Ruler
Line up tabs
and press in
sides one at a
time to attach
Gently press top
of push pad
Restore Power:
Restorepoweratcircuitbreakerorfuse.
Installation is complete.
Step 7
1-Zone Controller Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Installationmaynowbecompletedby
tighteningmountingscrewsintowallbox.
Attachwallplate.
Step 6
Excluding 1-Zone Controller from
Z-Wave
®
Network:
Including 1-Zone Controller into
Z-Wave
®
Network:
Factory Default:
Ifyour1-zonecontrollerisnotresponding,oryouareunabletocontrolit
afteryouhavetriedtoInclude/Excludeitmultipletimes,itmaybenecessary
toresetthe1-zonecontrollertoitsoriginalfactorysettings.Toaccomplish
this,proceedasfollows:
• Onthe1-zonecontroller,engagetheair-gapswitchbygentlypressing
thetopofthepushpaduntilthebottomliftscompletelyoutoftheframe
andaclickisheard(refer to figure).Wait5
secondsandthenpressthepushpadbackinto
theframeandholdpushpaduntilthelocatorLED
turnsAmberandthenturnsRed.Releasethe
pushpad.The1-zonecontrollerisnowreset.
Oncethecontrollerisreset,itwillbenecessaryto
Re-Includeittoanetworkbeforeitcanbeused.
CAUTION:SETTINGADEVICETOAFACTORY
DEFAULTDOESNOTEXCLUDETHATDEVICE
FROMANETWORK.THEEXCLUSION
PROCEDUREMUSTSTILLBEFOLLOWEDTO
REMOVETHEDEVICEFROMTHEPRIMARY
PROGRAMMERREMOTE’SINFORMATION
TABLE.FAILURETODOSOMAYRESULTIN
SYSTEMTHATISSLOWTORESPOND,ORMAY
FAILTORESPONDTOSOMEDEVICES.
DI-000-VRCZ1-02A
2008©LevitonMfg.Co.,Inc.
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
LevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenetofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforveyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,
atitsoption,ifwithinsuchveyearperiodtheproductisreturnedprepaid,withproofofpurchasedate,andadescriptionoftheproblemtoLeviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591.Thiswarrantyexcludesandthereisdisclaimedliability
forlaborforremovalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,abused,oralteredinanymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions.There are no other or
implied warranties of any kind, including merchantability and fitness for a particular purpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty,includingmerchantabilityandtnessforaparticularpurpose,islimitedtoveyears.Leviton is not liable for incidental,
indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.
Step 8 cont'd
Programmer/Remote
Cat. No. VRCPG
NOTE:Programmer/Remotemustbein
closeproximityto1-zonecontrollerwhen
includinginthenetwork.
For additional information, contact Leviton’s
Techline at 1-800-824-3005 or visit Leviton’s
website at www.ViziaRFplus.com
ProtectedunderU.S.PatentNumber6,388,399andpatentspendingand
licensedunderU.S.PatentsNumbers5,905,442,and5,982,103
Thisequipmenthasbeentestedandfoundtocomplywiththelimitsfor
aClassBDigitalDevice,pursuanttoPart15oftheFCCRules.These
limitsaredesignedtoprovidereasonableprotectionagainstharmful
interferenceinaresidentialinstallation.Thisequipmentgenerates,uses,
andcanradiateradiofrequencyenergyand,ifnotinstalledandusedin
accordancewiththeinstructions,maycauseharmfulinterferencetoradio
communications.However,thereisnoguaranteethatinterferencewill
notoccurinaparticularinstallation.Ifthisequipmentdoescauseharmful
interferencetoradioortelevisionreception,whichcanbedetermined
byturningtheequipmentOFFandON,theuserisencouragedtotryto
correcttheinterferencebyoneormoreofthefollowingmeasures:
• ReorientorrelocatethereceivingAntenna.
• Increasetheseparationbetweentheequipmentandthereceiver.
• Connecttheequipmentintoanoutletonacircuitdifferentfromthatto
whichthereceiverisconnected.
• Consultthedealeroranexperiencedradio/tvtechnicianforhelp.
FCC COMPLIANCE STATEMENT
A) IfusingaLevitonZ-Wave
®
Programmer/Remote,Cat.No.VRCPG,
presstheMenubuttonandscrolldowntoSystemSetup.Press
thecenterbuttontoselectSystemSetupMenu.ChooseAdvanced
Settings.PressthecenterbuttontoselectNetwork.Scrolldownand
pressthecenterbuttonto<ExcludeNode>.
B) IfusingVRCPGProgrammer/Remote,youwillbepromptedtoplace
1-zonecontrollerintoprogrammingmode.
C) ToaccessProgrammode,engagetheair-gapswitchbygently
pressingthetopofthepushpaduntilthebottomliftscompletelyout
oftheframeandaclickisheard(refer to figure).Wait5seconds
andthenpressthepushpadbackintotheframeandholdpush
paduntiltheLEDturnsAmber.ReleasethepushpadandtheLED
shouldblinkAmber.YouarenowinProgrammingmode.
NOTE:IftheLEDonthe1-zonecontrollerturnssolidRedwhile
excluding,therehasbeenacommunicationerror.
D) Whilestandingclosetothe1-zonecontroller(approximately2-5ft.),
pressthecenterbuttonontheProgrammer/Remoteto<Exclude>
devicefromthenetwork.
Step 9
TROUBLESHOOTING
• LocatorLEDoncontrollerdoesnotturnON
 - Circuitbreakerorfusehastripped.
 - If1-zonecontrollerispoweredupandLEDdoesnotturnON,
checkwiring.
• Zonecontrollerdoesnotoperatelights
-Checkassociation.
 -Ensurethatcontrollerwasproperlyupdated.
OPERATION
DIM/BRIGHT Bar
BRIGHTEN:
PresstherighthalfoftheDIM/BRIGHTBar
–Lightsbrightentodesiredlevel.
DIM:
PressthelefthalfoftheDIM/BRIGHTBar
–Lightsdimtodesiredlevel.
Ifthereisapoweroutage,whenthepoweris
restored,thelightswillreturntothelastsetting
beforethepowerinterruption.
Cleaning:Cleanwithadampcloth.DO NOT
usechemicalcleaners.
Virtual Matching Remote Application:
Push Pad (Default settings)
Turn ON from OFF position:
Tap–LightsturnON,LEDturnsOFF.
Turn OFF from ON position:
Tap–LightsturnOFF,LEDturnsON.
Push
Pad
LED
DIM/
BRIGHT
Bar
LED
Brightness
Display
Device Association:
After inclusion process, you must associate the devices to
the controllers. Refer to the Primary Programmer/Controller
instruction sheet for complete details.
Step 10
NOTE:One(1)Z-Wave
®
devicecanbeassociatedtomultipleprogrammer/
remotes(uptove(5)programmer/remotesmaximum).
NOTE:Ifusinganon-LevitonProgrammer/Remote,refertothe
Programmer/RemoteinstructionsheetforAssociatingadevice.
NOTE: Only one Vizia RF +
TM
dimmer can be associated to the 1-zone
controller.
Gently press top
of push pad
Definition of Mode
LEDOptions:SetsthetimeperiodinsecondstheLocatorLEDand
Brightnessdisplaywillstayonbeforeextinguishing.
NOTE:Theswitchwillexitprogrammodeafter3minutesofinactivity.
Program Mode
To enter programming mode:
PressandholdthepushpadandthentherighthalfoftheDIM/BRIGHT
bar
(
^
)
for5secondsuntiltheLocatorLEDstartsandtheleftmostLED
(LED1)begintoblink.
TheLocatorLEDwillblinkoncepersecondtoindicateProgramMode,
LED Options.TochangeLEDOptionssettingsusetheDIM/BRIGHTbarto
movetheLEDtothedesiredpresetsettingaccordingtothechartbelow.By
tappingthepushpad,thissettingwillautomaticallybesavedandthedevice
willexitprogrammingmode.
ADVANCED PROGRAMMING FEATURES
Active
Active
Active
Active
Turns off 5 seconds after use
Turns off 5 seconds after use
Active
Active
Turns off 5 seconds after use
LOCATOR LED TIMEOUT
1
2
3
4
5
6
7
LED
Turns off 5 seconds after use
Turns off 5 seconds after use
LED Bar active
LED Bar turns off 5 seconds after use
LED Bar turns off 5 seconds after use
LED BRIGHTNESS DISPLAY OPTIONS
G) Afteralldevicesareincludedintothenetwork,thecontrollermust
beupdatedtoallowpropernetworkfunction.Toupdatecontroller
proceedasfollows:
• Ifusinganon-LevitonProgrammer/Remote,refertothe
Programmer/Remoteinstructionsheetforupdatingcontroller.
• IfusingLevitonZ-Wave
®
Programmer/Remote,Cat.No.VRCPG,
presstheMenubuttonandscrolldown
toSystemSetup.Pressthecenter
buttontoselectSystemSetupMenu.
ChooseAdvancedSettings.Pressthe
centerbuttontoselectNetwork.Press
thecenterbuttontoselectUpdate
"cntrl".Whenpromptedpresspushpad
onthe1-zonedimmingcontroller.
• WaituntiltheVRCPGProgrammer/
Remoteconrmscompletion.Updateis
done.
NOTE: IfusingtheVRCPG'sInstallChecklist
feature,afteralldevicesareincluded,goto
UpdateControllersstep.
NOTE:Ifthe1-zonecontrollerhasbeen
successfullyIncludedinthenetworkand
theusertriestoIncludeitagainwithoutrst
excludingitfromthenetwork,thecontroller
willretaintherstnodeIDithadreceivedand
ignorethesecond.
Cat. No. VRCPG
1 ON
2 ON
3 ON
4 ON
OFF
OFF
OFF
OFF
Menu
Button
Center
Button
  • Page 1 1
  • Page 2 2

Z-Wave VRCZ1-1LZ Owner's manual

Type
Owner's manual

Z-Wave VRCZ1-1LZ is a 1-Zone Dimming Controller and Virtual Matching Dimmer Remote designed to provide remote control of your lighting. It operates on a 120VAC, 60Hz power supply and can be used with copper or copper clad wire. No traveler wires are needed as it communicates via radio frequency (RF) technology.

The device features ON/OFF and Brightness level LEDs for 2-way status reporting. It is compatible with other Z-Wave enabled devices and can be included in a Z-Wave network regardless of the manufacturer.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI