  • Hello! I am an AI chatbot trained to assist you with the Adey MagnaClean Professional2XP Installation And Servicing Instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Telephone: 01242 546717 Email: info@adey.com
www.adey.com
Produced from recycled material
A carbon neutral company
Installation and servicing
instructions
M13308
MagnaClean
®
Professional2XP in-line design and 360˚ rotational valves provide
multiple installation options for both vertical and horizontal pipework. This ensures
greater flexibility within the tightest working environments.
Multiple installation options
FOR BEST RESULTS
Install and service with MC1, the advanced system inhibitor from
the UK’s No 1 manufacturer of magnetic filters.
MagnaClean Professional2XP delivers exceptional domestic central heating system
protection against the damaging effects of black iron oxide sludge and
non-magnetic debris. The unique, full-flow, 28mm valves and increased filter
capacity establishes it as a leader in its class giving professional installers a
dedicated filter for larger central heating systems.
IMPORTANT Always follow the Standard Electrical Best Practice guidelines when
installing a MagnaClean filter. A copy of these guidelines can be found at
www.hse.gov.uk/electricity
The inlet and outlet on MagnaClean Professional2XP are reversible and there is no
flow restriction. Following installation, don’t forget to complete the warranty card.
Alternatively, complete the registration online at www.adey.com
This product is backed by a two year limited guarantee.
MagnaClean Professional2XP
MagnaClean
®
Professional2XP has been developed by the industry leading and
multi-award winning company that pioneered magnetic filtration. ADEY’s filters are
already protecting two million heating systems throughout the UK.
The x-treme performance dual-action filter can be installed anywhere on the main circuit.
However to achieve the best level of protection for the boiler, it is recommended that
MagnaClean Professional2XP is installed after the last radiator and before the boiler.
Installation
The following instructions are designed to
support engineers in the safe and effective
installation and servicing of MagnaClean
Professional2XP and should be followed at all
times.
Any queries should be directed to your
supervisor or ADEY direct on 01242 546717.
Open vented system Combi/Sealed system
In both diagrams, position A is best
practice, while B is suitable.
N.B. We firmly recommend MagnaClean
Professional2XP is installed and serviced
by a qualified heating engineer.
Your system is protected by
Annual service required
www.adey.com
2
Servicing
2
3
1
2
Open drain
Close
drain
Open vent
Take care not to
over tighten
4
No need to
over tighten
7
6 7
CUT AND REMOVE SECTION
1
3
4 5
6
2
1
2
1
Open vent
Turn
valves
OFF
1 3
1
2
3
4
Clean
Clean
5
Clean
Remove sleeve
2
1
Open
vent
Turn
valves
ON
8
188mm
Attach valve clips
Open
vent
Turn
valves
ON
/