Adey MagnaClean Micro 2 Installation And Servicing Instructions

  • Hello! I am an AI chatbot trained to assist you with the Adey MagnaClean Micro 2 Installation And Servicing Instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
2
Telephone: 01242 546717 Email: info@adey.com
www.adey.com
Produced from recycled material
A carbon neutral company
Installation and servicing
instructions
M02730 LF2-01-01366
MagnaClean
®
Micro2 incorporates a secure, quick-release, trigger which
enables the filter to be removed and re-installed in seconds.
The industry leading connections are an integral part of the new MagnaClean
Micro2 design. They enable easy and speedy filter removal during annual
servicing or to undertake a MagnaCleanse system flush. This also makes it ideal for
systems where there is little room to install a filter.
The following instructions are designed to support engineers in the safe and
effective servicing of MagnaClean Micro2 using the quick-release trigger.
Quick-release trigger
FOR BEST RESULTS
Install and service with MC1+, the advanced system inhibitor from
the UK’s No 1 manufacturer of magnetic filters.
Micro
Micro
1
54
N.B. Periodically remove collets
and lubricate seals with water
Replace the collets,
quick-release trigger
and canister.
3
Turn locking pin 90˚
and remove
Replace locking pin
and turn 90˚ to lock
CAUTION:
MagnaClean filter contains a strong magnet. Keep away from all electrical
devices, bank cards and other magnetic devices.
MagnaClean filter contains a strong magnet. Caution should be taken at all
times when handling if you have a pacemaker fitted.
MagnaClean filter is a pressurized device. Always release pressure
before servicing.
Unit may be hot in operation. Handle with care.
IMPORTANT Always follow the Standard Electrical Best Practice guidelines when installing a
MagnaClean filter. A copy of these can be found at http://www.hse.gov.uk/electricity
To maintain earth continuity in accordance with current IEE regulations, when required a
suitable earth bonding cable should be fitted to the pipework to bypass the product.
Refer to NICEIC 17th edition for more information
Maximum working pressure: 6 bar Maximum working temperature: 95°C
Flow rate: <50 l/min Flow: Bi-directional
Valve A: Double depth socket, slip couplet Valve B: Single depth socket
MagnaClean
®
Micro2 has been developed by the company that pioneered
magnetic filtration. ADEY’s filters protect more than three million central heating systems
in UK homes removing virtually 100% of the damaging suspended black iron oxide
sludge that builds up in all heating systems.
The dual-action filter can be installed anywhere on the main circuit. However, to achieve
the best level of protection for the boiler, it is recommended that MagnaClean Micro2 is
fitted after the last radiator and before the boiler.
Installation
Open vented system Combi/Sealed system
Your system is protected by
Annual service required
www.adey.com
Lubricate
with jointing
compound
2
Servicing
3
2
1
4
2
Open drain
Close
drain
Open vent
Take care not to
over tighten
4
No need to
over tighten
7
6 7
CUT AND REMOVE SECTION
1
1
2
3
Tighten compression nuts
4 5 8 9
6
2
1
3
Open
vent
Turn
valves
ON
10
1
2
3
Open vent
Turn
valves
OFF
1 3
1
2
3
4
Clean
Clean
5
Clean
Remove sleeve
1
2
3
Open
vent
Turn
valves
ON
8
Ensure pin is in
locked position
Micro
Micro
98mm
The following instructions are designed to support
engineers in the safe and effective installation
and servicing of MagnaClean Micro2 and should
be followed at all times. Ensure the filling loop
is fitted after the filter. The lid seal should be
checked for wear when servicing MagnaClean. It is
best practice to replace the lid seal at each service.
To arrange replacements please visit adeyspares.
co.uk or contact the ADEY Team on 01242 546717.
In both diagrams, position A is
recommended as part of ADEY’s Best
Practice
approach. Position B is suitable
if space is tight on the return.
When completing a system flush using
MagnaCleanse
®
always ensure this is
installed and carried out on the return
pipe of the system for optimum boiler
protection.
Close
vent
Close
vent
Close
vent
Close
vent
/