Heiman HS1SA-Z User manual

  • Hello! I've reviewed the provided guide document for the HS1SA-Z Z-Wave smoke detector. This document details how to add, remove, test and reset the device, also includes information on association groups, alarm notifications, and technical specifications. I'm here to assist with your questions about this device.
  • How to add the device to Z-Wave network?
    How to remove the device from Z-Wave network?
    How to test if the device is working?
    How to reset device to factory?
HS1SAZ
ZWaveDevice
GuideDocument

Productdescripion
ProductisS2Unauthenticateddevices.
ThisdeviceisasecurityenableZ-WavePlusproductthatisabletouseencryptedZ-WavePlus
messagestocommunicatetoothersecurityenableZ-WavePlusproducts.
Note:A"SecurityEnableZ-WaveController"mustbuusedinordertofullyutilizethisfunction.
1DeviceADDforInclusion
‐  Click[Add]iconinZWaveController.
‐  PresstheNet_Button3timeswithin1.5s,GreenLEDisBlinking3timeswithin1second.
‐  IfInclusionProcessissuccessful,Greenledwillturnoff.
2DeviceRemoveforExclusion
‐  Click[Remove]iconinZWaveController
‐  PresstheNet_Button3timeswithin1.5s
‐  IfExclusionProcessissuccessful,GreenledisBlinking6times,thenturnoff.
3Devicetestmode
ifInclusionprocessissuccessful,PressTest_Buttontotestifthedeviceisworkingnormally.
RedLEDflashesthedevice3timesandsendsoutasmokeevent,thenwhentheredLEDturn
offthedevicesendsoutasmokefreeevent.
4Devicedetectionmode
ifInclusionprocessissuccessful,thedevicewillreportalarminformationifdetectthestatus
changeofsmokeandnosmoke.RedLEDblinksquicklywhensmokeisdetected.
5DeviceFactoryReset
‐‐LongpressNet_Buttonatleast10secondsintheproduct.
‐DeviceResetLocallynotificationisTransmitted.
.Pleaseusethisprocedureonlywhenthenetworkprimarycontrollerismissingorotherwise
Test_Button/LED
Indicator
Net_Button
inoperable.
6Association&AssociationGroupInformation
‐  LifelinebetweencontrollerandHS1SAZ
‐Supportedcommandclasses
Batteryreport,Notificationreport,andDeviceResetLocallynotification.
‐AssociationGroupdescription
Associationgroup1:Lifelineassociationgroup
‐Maximumsupportednodeis5.
Includecommandclasses:Batteryreport,Notificationreport,andDeviceResetLocally
notification,
Associationgroup2:RootDevicegroup(Basicset)
‐Maximumsupportednodeis5.
TheSensorsendsaBasicSetcommandtodirectlytriggerdevices(likealight,switch,etc.)in
responsetoevents.ThevalueoftheBasicSetcommand(e.g.Sirentrigger)isconfiguredusing
smokeornosmoke
ThisparametersetsthevaluesentbytheBASIC_SETcommandtoAssociationGroupforSmoke
event
BASIC_SETLevel0xFFTurnOnDevice
ThisparametersetsthevaluesentbytheBASIC_SETcommandtoAssociationGroupforno
smokeevent
BASIC_SETLevel0x00 TurnOffDevice
7NotificationReport
Pressorreleasetestbutton,orsmokestatusischanged(smokedetectedornosmoke
detected),NotificationReportistransmitted
8BatteryReport
‐  BatteryReportistransmittedwhenpoweronthedevice.
‐  BatteryReportistransmittedonceaday.
‐  BatteryReportistransmittedwhenthebatteryfallslessthan0%
‐
BatteryVoltageBatteryLevel
2.4V~3.0V0~100(%)
Under2.4V 0xFF
NotificationType
Event
SmokeAlarm
(0x01)
PreviousEventscleared
(0x00)
Smokedetected,
UnknownLocation(0x02)
9WakeupNotification
‐  WakeupNotificationistransmittedevery24hoursbydefault.
‐  WakeupNotificationistransmittedwhenpoweristurnon.
10Devicesfrommultiplemanufacturersinonenetwork
‐  ThisproductcanbeincludedandoperatedinanyZWavenetworkwith
otherZWavecertifieddevicesfromothermanufacturersand/orother
applicants.Allnonbatteryoperatednodeswithinthenetworkwillactas
repeatersregardlessofvendortoincreasereliabilityofthenetwork.
11ZWaveSpecifications
11.1DeviceType:Sensor‐Notification
11.2RoleType:RSS(ReportingSleepingSlave)
11.3CommandClassSupport/Control
11.3.1ZWaveplusInfoVersion2
11.3.2NotificationVersion8
11.3.3AssociationVersion2
11.3.4AssociationGroupInfoVersion1
11.3.5TransportServiceVersion2
11.3.6VersionVersion3
11.3.7ManufacturerSpecificVersion2
11.3.8DeviceResetLocallyVersion1
11.3.9PowerlevelVersion1
11.3.10BatteryVersion1
11.3.11Security2Version1
11.3.12SupervisionVersion1
11.3.13Wake Up Version 2
11.3.14MultiChannelAssociationVersion3
11.4-The below listed CommandClassareallSupportedtheSecurityS2
11.4.1NotificationVersion8
11.4.2AssociationVersion2
11.4.3AssociationGroupInfoVersion1
11.4.4VersionVersion3
11.4.5ManufacturerSpecificVersion2
11.4.6DeviceResetLocallyVersion1
11.4.7PowerlevelVersion1
11.4.8BatteryVersion1
11.4.9Wake Up Version 2
11.4.10MultiChannelAssociationVersion3
12IndicateLEDstatuesdescription‐
statusLEDstatusAlarmsound
Normal RedLEDflashevery53s Nosound
TestmodeRedLEDflashquicklySoundDiDiDiloudly
AlarmRedLEDflashquicklySoundDiDiDiloudly
SilencemodeRedLEDflash1timeevery10
seconds
Nosound
LowbatteryRedLEDflash1timeevery53
seconds
Sound“Di”every53seconds
Fault RedLEDflash2timesevery
53seconds
Sound“Di”twiceevery53
seconds
13Howtoreplacethebatteries
Turnrighttodismantlethemountingbaseof
thedevice
1)takeoutbatteryfromthedevice
2)Insertthebatteryintothedevice
(Youmustbecarefulofthebattery
polarity)
Turnlefttoinstallthemountingbaseofthe
device
(beforeinstallthemountingbase,youshould
mustinsertbatteryfirstly,otherwisethe
mountingbasewillnotbefixed)
14TechnicalSpecifications
ModelNo.HS1SAZ
RFfrequency868.40869.85MHz
RFoperatingdistanceUpto100moutdoorlineofsight
Upto40mindoor
Poweredby1xCR123A
Temperature10~50
Humidity95%max
Weight69.2g(batteries)
/