‐ Click[Add]iconinZ‐WaveController.
‐ PresstheNet_Button3timeswithin1.5s,GreenLEDisBlinking3timeswithin1.5second.
‐ IfaddProcessissuccessful,GreenLEDwillturnoff.
2‐DeviceRemoveforExclusion
‐ Click[Remove]iconinZ‐WaveController.
‐ PresstheNet_Button3timeswithin1.5second.
‐ IfremoveProcessissuccessful,GreenLEDisBlinking6times,thenturnoff.
3‐Devicenormalmode
Thedeviceispoweredon.TheredLEDisonfortwosecondstoextinguish.Thedeviceis
poweredon.Ifthedeviceisaddedtothegateway,thegatewaycancontrolthedevicealarmand
cancelthealarm.Whenthealarmmodeisused,thedeviceemitsanalarmsoundandthered
LEDflashes.
‐Backupbattery:
Themainpoweroftheequipmentiscutoff,andthebackupbatteryisusedtokeepthe
equipmentonstandbyfor4hours,andthentheequipmentcanalsobealarmedfor5minutes.
4‐DeviceFactoryReset
‐LongpressNet_Buttonatleast10secondsintheproduct.
‐DeviceResetLocallynotificationisTransmitted.
Pleaseusethisprocedureonlywhenthenetworkprimarycontrollerismissingorotherwise
inoperable.
5‐Association&AssociationGroupInformation
‐LifelinebetweencontrollerandHS2WD‐Z
‐Supportedcommandclasses
DeviceResetLocally,BatteryandSwitchBinaryreport.
‐Maximumsupportednodeis5
‐AssociationGroupdescription
Associationgroup1:Lifelineassociationgroup
Includecommandclasses:SwitchBinaryreport,BatteryandDeviceResetLocallynotification.
6‐BinarySwitchReport
‐Gatewaycansetdevicealarmandshutdownalarm
‐BinarySwitchReportis0xfftosetalarm
‐BinarySwitchReportissetto0x00tocancelthealarm
7‐Devicesfrommultiplemanufacturersinonenetwork
‐ ThisproductcanbeincludedandoperatedinanyZ‐Wavenetworkwith
otherZ‐Wavecertifieddevicesfromothermanufacturersand/orother
applicants.Allnon‐batteryoperatednodeswithinthenetworkwillactas
repeatersregardlessofvendortoincreasereliabilityofthenetwork.
SwitchTypeValueStatus
BinarySwitchReport
0x00OFF
0xFFON