CEM DT-338 Operating instructions

Category
Multimeters
Type
Operating instructions
Please read this manual before switching the unit on.
Important safety information inside.
True RMS Low Current
Clamp Meter
User Manual
True RMS Low Current
Clamp Meter
User Manual
True RMS Low Current Clamp Meter User Manual
3
True RMS Low Current Clamp Meter User Manual
Contents
1. Safety ................................................................................................
1-1. International Safety Symbols ........................................................
1-2. Safety Notes ................................................................................
1-3. Warnings .....................................................................................
1-4. Cautions ......................................................................................
2. Meter Description ...............................................................................
3. Specifications ....................................................................................
4. Operation ............................................................................................
4-1. AC/DC Current Measurements ......................................................
4-2. AC/DC Voltage Measurements ......................................................
4-3. Resistance Measurements ...........................................................
4-4. Diode Measurements ...................................................................
4-5. Capacitance Measurements..........................................................
4-6. Frequency measurements - AC Only.............................................
4-7. Temperature Measurements..........................................................
4-8. Battery Replacement.....................................................................
1-
1-
1-
1-
1-
1-
1-
1-
1-
1-
1-
1-
Page
4
4
4
4
4
5
6
10
10
11
11
11
12
12
12
12
1. Safety
1-1. International Safety Symbols
This symbol, adjacent to another symbol or terminal, indicates the user must
refer to the manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use,
hazardous voltages may be present
Double insulation
1-2. Safety Notes
• Do not exceed the maximum allowable input range of any function
• Do not apply voltage to meter when resistance function is selected.
• Set the function switch OFF when the meter is not in use.
1-3. Warnings
• Set function switch to the appropriate position before measuring.
• When measuring volts do not switch to current/resistance modes.
• When changing ranges using the selector switch always disconnect the test
leads from the circuit under test.
• Do not exceed the maximum rated input limits.
1-4. Cautions
Improper use of this meter can cause damage, shock, injury or death. Read
and understand this user manual before operating the meter. Always remove
the test leads before replacing the battery. Inspect the condition of the test leads
and the meter itself for any damage before operating the meter. Repair or replace
any damage before use.
Use great care when making measurements if the voltages are greater than
25VAC rms or 35VDC. These voltages are considered a shock hazard. Remove
the battery if the meter is to be stored for long periods.
Always discharge capacitors and remove power from the device under test
before performing Diode, Resistance or Continuity tests.
• Voltage checks on electrical outlets can be difficult and misleading because
of the uncertainty of connection to the recessed electrical contacts. Other
means should be used to ensure that the terminals are not "live".
• If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
4
True RMS Low Current Clamp Meter User Manual
5
True RMS Low Current Clamp Meter User Manual
Input Limits
Function
A
V DC, V AC
Frequency, Resistance, Diode, Continuity ,
Capacitance Test
Maximum Input
80A DC/AC
600V DC/AC
250V DC/AC
2. Meter Description
1-Current clamp
2-Clamp trigger
3-Rotary Function swith
4-Data Hold button
5-Back Light button
6-LCD display
7-MODE select button
8-PEAK button
9-MAX/MIN button
10-Relative button
11-COM input jack
12-V Ω CAP
TEMP Hz jack12-
010 20 30 40
1
2
4
6
7
89
10
11 12
3
5
9
True RMS Low Current Clamp Meter User Manual
11
True RMS Low Current Clamp Meter User Manual
12
True RMS Low Current Clamp Meter User Manual
4-5. Capacitance Measurements
WARNING: To avoid electric shock, disconnect power to the unit under
test and discharge all capacitors before taking any capacitance
measurements. Remove the batteries and unplug the line cords.
• Set the rotary function switch to the CAP position.
• Insert the black test lead banana plug into the negative COM jack.
Insert the red test lead banana plug into the positive V jack.
• Touch the test leads to the capacitor to be tested.
• Read the capacitance value in the display
4-6. Frequency measurements - AC Only
• Set the rotary function switch to the “Hz” position.
• Insert the black lead banana plug into the negative COM jack and the red test
lead banana plug into the positive V jack.
• Touch the test probe tips to the circuit under test.
• Read the frequency on the display.
4-7. Temperature Measurements
WARNING: To avoid electric shock, disconnect both test probes from any source
of voltage before making a temperature measurement.
• Set the function switch to TEMP.
• Insert the Temperature Probe into the negative COM and the V jacks, making
sure to observe the correct polarity.
• Touch the Temperature Probe head to the material surface you intend to measure.
Keep the probe touching the part under test until the reading stabilizes (about
30 seconds).
• Read the temperature in the display. The digital reading will indicate the proper
decimal point and value.
WARNING: To avoid electric shock, be sure the thermocouple has been removed
before changing to another measurement function
4-8. Battery Replacement
• Remove the one rear Phillips head screw
• Open the battery compartment
• Replace the Requires One 9V battery
• Re-assemble the meter
WARNING:
WARNING:
True RMS Low Current Clamp Meter User Manual
True RMS Low Current Clamp Meter User Manual
Rev.150514
True RMS Low Current Clamp Meter User Manual
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

CEM DT-338 Operating instructions

Category
Multimeters
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI